Coronary complications of PCI: scope and classification
The coronary complications of percutaneous coronary intervention (PCI) are injuries to the treated artery, its branches, the microcirculation, or the aortic root that arise from wires, balloons, stents, atherectomy devices, guide catheters, or the embolized contents of the lesion. They fall into two groups by timing. Procedural complications appear during the procedure: perforation, no-reflow and distal embolization, dissection, abrupt closure, side-branch occlusion, air embolism, spasm, and device entrapment. Late failures of the stented segment appear after the patient has left the laboratory. Stent thrombosis presents abruptly, usually as myocardial infarction; in-stent restenosis presents gradually, with recurrent angina or as an acute coronary syndrome.
The complications of diagnostic catheterization, including catheter-induced dissection rates, cholesterol embolization, and access-site injury, are on the coronary angiography hub. PCI technique, vascular access, intravascular imaging with intravascular ultrasound (IVUS) and optical coherence tomography (OCT), complex lesion preparation, and radiation safety in the catheterization laboratory enter the sections below where they cause, reveal, or treat a coronary complication. Full coverage is on the hubs for PCI equipment and technique, vascular access, intravascular imaging, complex PCI, and catheterization laboratory radiation safety.
The governing US document for revascularization is the 2021 American College of Cardiology (ACC), American Heart Association (AHA), and Society for Cardiovascular Angiography and Interventions (SCAI) guideline for coronary artery revascularization, with its published corrections (Lawton 2022). The 2025 ACC/AHA acute coronary syndromes (ACS) guideline, with its corrections, governs primary PCI adjuncts (Rao 2025). The 2021 guideline downgraded embolic protection devices in saphenous vein graft PCI from Class 1 to Class 2a (ACC 2022). Stent thrombosis is defined by the Academic Research Consortium (ARC) (Cutlip 2007; Garcia-Garcia 2018), and SCAI has published an expert consensus statement on in-stent restenosis and stent thrombosis (Klein 2023). Much of complication management rests on registries, device approvals, and case series; randomized trials exist for embolic protection, vasodilators in primary PCI, thrombus aspiration, deferred stenting, and the treatment of restenosis.
| Complication | Usual timing | Dominant mechanism | Angiographic or clinical signal | First response |
|---|---|---|---|---|
| Coronary perforation | During wiring, balloon or stent expansion, or atherectomy | Wire exit, oversized or high-pressure balloon, atheroablation | Extraluminal crater, blush, or contrast streaming; chest pain, hypotension, effusion | Balloon occlusion at the leak, echocardiography, reversal decision, sealing by location |
| No-reflow and slow flow | After balloon inflation, stent deployment, atherectomy, or reperfusion | Distal embolization, microvascular spasm, reperfusion injury | TIMI flow below 3 in a patent artery without residual obstruction | Exclusion of a mechanical cause, distal intracoronary vasodilator, blood pressure support |
| Distal embolization | During intervention on thrombus or degenerated vein grafts | Release of thrombus and friable plaque | Abrupt cutoff of a distal branch, filling defect | Aspiration, glycoprotein IIb/IIIa inhibitor, vasodilators; prevention with embolic protection |
| Flow-limiting dissection | After balloon or stent expansion, or deep guide engagement | Plaque fracture extending into the media | Persistent extraluminal contrast, spiral filling defects, reduced flow | Wire position maintained; stent across the entry and the flap |
| Aortocoronary dissection | During guide engagement or contrast injection | Ostial tear propagating retrograde into the sinus or aorta | Contrast staining at the ostium and in the sinus | Stent at the ostial entry; surgery for extension along the ascending aorta |
| Abrupt closure | During or soon after PCI | Dissection, thrombus, spasm, side-branch or plaque shift | Loss of antegrade flow with ischemia | Recrossing, stenting, antithrombotic adjustment |
| Air embolism | Immediately after an injection or device exchange | Air entering through the manifold or catheter | Abrupt filling defect, slow flow, ischemia, bradycardia, or arrest | Oxygen, aspiration or forceful saline flushes, hemodynamic support |
| Device entrapment or stent loss | During delivery or withdrawal in calcified, angulated anatomy | Stent stripping, burr or wire entrapment | Unexpanded stent off the balloon, immobile device | Retrieval by balloon, snare, or wires; crushing or deployment in place |
| Stent thrombosis | Hours to years after implantation | Underexpansion, malapposition, antiplatelet cessation, neoatherosclerosis | Usually ST-elevation myocardial infarction | Emergency angiography and PCI, intravascular imaging |
| In-stent restenosis | Months to years | Neointimal hyperplasia, neoatherosclerosis, underexpansion, fracture | Recurrent angina or acute coronary syndrome | Imaging to define the mechanism; drug-coated balloon or repeat drug-eluting stent |
Coronary complications of PCI by timing, mechanism, signal, and first response. TIMI, Thrombolysis in Myocardial Infarction flow grade.
Frequency of PCI complications and risk prediction in the NCDR CathPCI Registry
Contemporary US data come from the National Cardiovascular Data Registry (NCDR) CathPCI Registry. In 3,759,268 PCIs performed from 2009 to 2015, perforation occurred in 0.37%, with no change over the period (Nairooz 2020). In 291,380 patients with acute myocardial infarction (MI) undergoing PCI, no-reflow occurred in 2.3% (Harrison 2013). Emergency coronary artery bypass grafting (CABG) fell from 2.9% of PCIs in the era before stents to 0.3% in the most recent stent era studied at a single high-volume center. The in-hospital mortality of patients who needed it stayed between 10% and 14% (Yang 2005). In a US nationwide sample of 1,605,641 elective PCIs, 0.3% of patients underwent CABG within 24 hours (Pancholy 2021).
The CathPCI in-hospital mortality model, rebuilt after the registry added variables for clinical acuity, was developed in 706,263 PCIs at 1,608 sites. Procedural urgency, cardiovascular instability, and level of consciousness after cardiac arrest were the strongest predictors of death. The full model had a C-index of 0.943 in validation, and the median hospital risk-standardized mortality was 1.9% (Castro-Dominguez 2021). The model is used for benchmarking and for preprocedural counseling. It predicts death from all causes, most of which reflect the presentation; the rarer procedural complications carry their own predictors.
Structured response to a complication in the catheterization laboratory
Complications are recognized and managed by mechanism (Doll 2018). A response sequence that the whole team knows in advance shortens the delay between recognition and treatment.
- Recognition and announcement: the operator states the complication aloud and assigns roles, including a person to record times and drugs.
- Wire position: guidewire access across the lesion is kept, because wire access lost in a dissected or perforated artery may not be regained.
- Hemodynamics: arterial pressure, rhythm, and oxygenation are supported; vasopressors, atropine, and a defibrillator are ready, and pacing is available for bradycardia and heart block.
- Imaging the mechanism: orthogonal angiographic views define the problem; bedside echocardiography assesses pericardial effusion and ventricular function.
- Specific equipment: the device for the identified mechanism (a balloon for occlusion, a covered stent, coils, a microcatheter, a snare, or an aspiration catheter) is opened and prepared while the temporary measure continues.
- Escalation: cardiac surgery, anesthesia, and mechanical circulatory support teams are called early when sealing, reperfusion, or hemodynamic stability is uncertain.
- Documentation and disclosure: the sequence, drugs, and devices are recorded, and the patient and family are informed after stabilization.
Coronary perforation: incidence, mechanisms, and risk factors
Coronary perforation is a breach of the arterial wall with extravasation of contrast and blood beyond the vessel. In a meta-analysis of 67 all-comer cohorts that included 5,568,191 PCIs from 1982 to 2020, the pooled incidence was 0.39%, about 1 in 250 procedures, and it did not change over the period. Tamponade followed 21.1% of perforations, and mortality was 7.5%, with a downward trend. Distal wire exit caused 37% of perforations and balloon dilation 28%; covered stents were used in 25%, and emergency surgery was needed in 17% (Mikhail 2022). An earlier meta-analysis of 197,061 PCIs gave a pooled incidence of 0.43% and identified complex lesions and atheroablative devices as the most reproducible risk factors (Shimony 2011).
The NCDR CathPCI Registry quantifies the predictors in US practice. Chronic total occlusion (CTO) PCI (odds ratio 2.59), atherectomy with laser or rotational devices (2.38), ACC/AHA type C lesions (1.48), female sex (1.38), saphenous vein graft PCI (1.2), and cardiogenic shock at presentation (1.15) predicted perforation. Patients with perforation had more cardiogenic shock (7.73% against 1.02%), tamponade (9.6% against 0.05%), and in-hospital death (4.87% against 1.14%) (Nairooz 2020). Female sex, hypertension, chronic kidney disease, and prior CABG were risk factors in the pooled analysis (Mikhail 2022).
The mechanism of perforation depends on the device. Polymer-jacketed and stiff guidewires exit at the vessel tip, in a small side branch, or through a collateral channel. Balloons and stents rupture the vessel when oversized, inflated at high pressure in calcified segments, or expanded in a subintimal track. Atheroablative devices remove tissue: in the registry that defined the angiographic grades, perforation occurred in 1.3% of procedures with atherectomy and laser devices and in 0.1% with balloon angioplasty (Ellis 1994).
| Source | Population | Incidence | Tamponade | Mortality |
|---|---|---|---|---|
| Ellis 1994 registry | 12,900 procedures, 1990–1991 | 0.5% | 8%, 13%, and 63% for grades I, II, and noncavity III | 0%, 0%, and 19% for grades I, II, and noncavity III |
| Shimony 2011 meta-analysis | 16 studies, 197,061 PCIs | 0.43% | 0.4%, 3.3%, and 45.7% for grades I, II, and III | 0.3%, 0.4%, and 21.2% for grades I, II, and III |
| Nairooz 2020 (NCDR CathPCI) | 3,759,268 PCIs, 2009–2015 | 0.37% | 9.6% | 4.87% in hospital |
| Harnek 2019 (Swedish registry) | 243,149 patients, 2005–2017 | 0.42% | 21% of perforations had late tamponade | 16% at 1 year |
| Mikhail 2022 meta-analysis | 67 studies, 5,568,191 PCIs | 0.39% | 21.1% | 7.5% |
| Kostantinis 2022 (CTO registry) | 10,454 CTO PCIs | 4.9% | 14% needed pericardiocentesis | Major adverse events 18% |
Incidence and outcome of coronary perforation in registries and meta-analyses. CTO, chronic total occlusion; NCDR, National Cardiovascular Data Registry.
Perforation grade, location, and tamponade risk
Perforations are graded by their angiographic appearance into grade I (extraluminal crater without extravasation), grade II (pericardial or myocardial blush), grade III (a hole of 1 mm or more with contrast streaming), and cavity spilling into a cardiac chamber or the coronary sinus (Ellis 1994). The definitions and the original outcome data are on the coronary angiography hub. Tamponade and mortality rise steeply with grade: pooled tamponade rates were 0.4%, 3.3%, and 45.7%, and mortality 0.3%, 0.4%, and 21.2%, for grades I, II, and III (Shimony 2011). Grade III perforations accounted for 43% of perforations in the meta-analysis of 67 cohorts, a proportion that has risen (Mikhail 2022).
Location determines the sealing strategy. Large-vessel perforations occur in the main artery or a major branch, usually from a balloon, stent, or atherectomy device, and are sealed with prolonged balloon occlusion and, when that fails, a covered stent. Distal perforations occur at the tip of a wire in a small terminal branch, where no stent can reach, and are sealed by occluding the feeding branch with coils, fat, thrombin, or other embolic material. Collateral perforations occur during retrograde CTO PCI through septal or epicardial channels. A collateral channel can be fed from both ends, so embolization may be required from both the donor and the recipient sides. In 10,454 CTO procedures, the retrograde approach caused 47% of perforations, guidewire exit was the most common mechanism, and the grade distribution was 20% grade I, 41% grade II, 28% grade III, and 11% cavity spilling (Kostantinis 2022).
| Grade or location | Appearance | Tamponade risk | Usual management |
|---|---|---|---|
| Grade I | Crater outside the lumen without extravasation | Low | Balloon occlusion if the crater enlarges; observation and echocardiography |
| Grade II | Pericardial or myocardial blush without a jet | Low to moderate; may be delayed | Prolonged balloon occlusion; embolization of a distal source; serial echocardiography |
| Grade III, large vessel | Jet of contrast through a hole of 1 mm or more | High | Immediate balloon occlusion, pericardiocentesis for tamponade, covered stent, surgery when sealing fails |
| Grade III, distal wire exit | Jet from a terminal branch | High if bleeding continues under anticoagulation | Microcatheter at the branch, coils, fat, thrombin, or gelatin sponge |
| Collateral (CTO) | Extravasation from a septal or epicardial channel | Depends on whether the channel drains to the pericardium | Embolization, sometimes from both the donor and the recipient side |
Management of coronary perforation by grade and location (Ellis 1994; Shimony 2011; Kostantinis 2022; Doll 2018).
Recognition of perforation and tamponade during and after PCI
Perforation is recognized from the image, the patient, and the pressure tracing. Angiographic signs are an extraluminal crater, staining that persists after contrast clears, a jet of contrast toward the cardiac border, or contrast layering in the pericardial space. Clinical features are sudden chest pain, nausea, vagal bradycardia, and hypotension. The arterial pressure falls and the heart rate rises as the pericardium fills; fluoroscopy shows reduced excursion of the cardiac border. Bedside echocardiography confirms an effusion and chamber collapse and guides drainage.
Acute hemopericardium causes tamponade at small volumes, because the pericardium has no time to stretch. Pericardiocentesis is performed in the laboratory by the subxiphoid route under fluoroscopy, echocardiography, or both, with the drainage catheter left in place. The technique is described on the pericardiocentesis section of the pericardial effusion hub, and the causes and urgency of tamponade are compared there under causes of tamponade. Iatrogenic hemopericardium is drained by needle because the blood is fresh and unclotted. Surgical drainage is needed when clot forms or bleeding exceeds the rate of percutaneous control, as described under iatrogenic cardiac injury.
Delayed tamponade. Tamponade can develop hours after a perforation appears sealed, as anticoagulation persists or a distal leak reopens. In the Swedish national registry of 1,008 perforations, 21% of patients had late tamponade, and 78% of these perforations had not been recognized in the laboratory. Mortality after late tamponade (25.6% at 1 year) matched that after acute tamponade (27%) (Harnek 2019). Patients with a perforation of any grade therefore have repeat echocardiography before discharge and whenever hypotension, tachycardia, or chest pain occurs after the procedure. Unexplained hypotension after PCI is treated as tamponade or retroperitoneal bleeding until imaging excludes both.
Tamponade after prior CABG. After bypass surgery, pericardial adhesions limit free bleeding into the pericardial space. A perforation can still produce a loculated effusion that compresses individual cardiac chambers and causes hemodynamic compromise. In a literature review of perforations with hemodynamic compromise in patients with prior CABG, mortality was 22% (Karatasakis 2016).
Sealing a large-vessel perforation: balloon occlusion, covered stents, and the dual-guide technique
Prolonged balloon occlusion. The first action for a grade II or III perforation in an accessible segment is inflation of a balloon, sized to the vessel and at low pressure, proximal to or across the leak. The balloon stops extravasation, allows time for pericardiocentesis and equipment preparation, and seals some perforations outright. Inflations are maintained for several minutes and released briefly to assess the leak; distal ischemia limits the duration. In a CTO registry, prolonged balloon inflation was used in 23% of perforations (Kostantinis 2022).
Covered stents. A covered stent excludes the hole from the lumen. Two covered coronary stents hold US Food and Drug Administration (FDA) humanitarian device exemptions (HDEs). The Jostent coronary stent graft (Abbott Vascular Devices) is indicated for free perforations with contrast extravasation into the pericardium in native coronary arteries or saphenous vein grafts 2.75 mm or more in diameter (FDA HDE H000001). The PK Papyrus covered coronary stent system (Biotronik) is indicated for acute perforations of native coronary arteries and bypass grafts 2.5 to 5.0 mm in diameter (FDA HDE H170004). In a registry of 106 patients with large-vessel perforation sealed with polytetrafluoroethylene-covered (GraftMaster) or polyurethane-covered (Papyrus) stents, death, MI, and stent thrombosis at 30 days and 1 year did not differ. Target-lesion and target-vessel revascularization at 30 days were lower with the polyurethane-covered stent (Bartuś 2021). Covered stents have larger crossing profiles than drug-eluting stents, need a guide of adequate inner diameter and strong support, and jail any side branch they cover. In the NCDR registry, use of a covered stent was strongly associated with adverse events (odds ratio 3.67), a reflection of the severity of the perforations that require one (Nairooz 2020).
Dual-guide technique. When the covered stent is delivered, the occluding balloon has to be deflated and withdrawn, and the leak reopens. The dual-guide (block-and-deliver) technique avoids this. A second guide catheter engages the same ostium from another arterial access; one guide keeps the balloon inflated at the leak, and the balloon is deflated only for the seconds needed to pass a second wire and then the covered stent through the other guide. In 8 grade III perforations treated in this way, the covered stent sealed the perforation in 6, pericardiocentesis was needed in 3, and 1 patient died (Röther 2015).
Surgery. Surgical repair, ligation, or bypass is required when percutaneous sealing fails, when the anatomy is unsuitable, or when bleeding continues despite drainage.
Distal wire and collateral perforations: coils, fat, thrombin, and other embolic agents
Distal wire exit is the most common mechanism of perforation in pooled series, accounting for 37% of perforations (Mikhail 2022). Distal wire perforations are often small at first and become dangerous because heparin prevents sealing. A balloon is inflated in the feeding branch, and a microcatheter is advanced to the perforated branch for delivery of an embolic agent. Coils are the standard agent; they are precise but require a compatible microcatheter. Autologous subcutaneous fat, cut into small particles, is injected through the microcatheter as an alternative to coils (Shemisa 2017). Intracoronary thrombin injected through a microcatheter has sealed guidewire perforations in small tertiary branches (Fischell 2011), and absorbable gelatin sponge particles sealed all 6 distal perforations in a small series (Hashemi 2024). In the CTO registry, coils were used in 6% and fat in 4% of perforations (Kostantinis 2022).
Embolization occludes the perforated branch, so a small infarct in its territory is expected.
Anticoagulation and antiplatelet management after perforation: protamine, bivalirudin, and glycoprotein IIb/IIIa inhibitors
Protamine. Unfractionated heparin is reversed with protamine sulfate. One milligram neutralizes not less than 100 United States Pharmacopeia (USP) units of heparin; no single dose exceeds 50 mg, and the drug is given by very slow intravenous injection over 10 minutes. Neutralization occurs within 5 minutes. The boxed warning describes severe hypotension, cardiovascular collapse, and noncardiogenic pulmonary edema, and risk factors include high doses, rapid injection, fish allergy, prior vasectomy, and exposure to protamine-containing insulin (protamine label). The timing of reversal is weighed against the need for further equipment in the artery, because protamine given with a guide, wire, and fresh stent in place exposes them to thrombosis. Dosing by heparin given in the preceding hours is set out in the bleeding and reversal hub.
Bivalirudin. There is no antidote to bivalirudin. Its half-life is 25 minutes in patients with normal kidney function, and coagulation times return to baseline about 1 hour after the infusion stops (bivalirudin label). The infusion is stopped at once, and sealing relies on mechanical measures for that hour.
Glycoprotein IIb/IIIa inhibitors. These drugs impair sealing, and the infusion is stopped when a perforation occurs. The eptifibatide label directs immediate discontinuation when bleeding cannot be controlled. Its plasma half-life is about 2.5 hours; inhibition of platelet aggregation is reversible, falling below 50% at 4 hours after the infusion stops, and the bleeding time remains 1.4 times baseline at 6 hours (eptifibatide label). Stopping oral antiplatelet therapy after recent stenting exposes the stent to thrombosis, a second lethal complication.
Emergency surgery and hemodynamic support for PCI complications
In a single-center series, patients who needed emergency CABG after PCI in the stent eras had more hypertension, prior revascularization, left ventricular dysfunction (ejection fraction below 40%), and complex coronary lesions than those in the pre-stent era, and their in-hospital mortality stayed between 10% and 14% (Yang 2005). In elective PCI, a preprocedural score identified a top tertile with twice the average rate of emergency CABG within 24 hours (0.6% against 0.3%) (Pancholy 2021). The indications are a perforation that cannot be sealed, a dissection or closure that cannot be stented, an aortocoronary dissection that extends up the ascending aorta, an entrapped device that cannot be retrieved, and ischemia in a large territory despite an open artery.
Hemodynamic support bridges the patient through the complication. An intra-aortic balloon pump raises diastolic coronary perfusion pressure and was used in 30% of patients with no-reflow in a primary PCI series, against 4.3% of patients without it (Brosh 2007). Microaxial flow pumps and venoarterial extracorporeal membrane oxygenation support patients in cardiogenic shock or arrest from a complication; device physiology and selection are on the balloon pump, Impella, VA-ECMO, and cardiogenic shock hubs. Tamponade is drained before mechanical support is judged ineffective, because a pump cannot restore output while tamponade prevents ventricular filling.
No-reflow and slow flow: definition and angiographic grading
No-reflow is inadequate myocardial perfusion through an epicardial artery that is open, without dissection, spasm, thrombus, or residual stenosis to explain it. On angiography it appears as Thrombolysis in Myocardial Infarction (TIMI) flow grade below 3, a prolonged frame count, or absent myocardial blush in a patent vessel. Slow flow and no-reflow both describe a delay in contrast progression after successful revascularization of the culprit vessel, and the terms are used for degrees of the same process (Brugaletta 2026). Registries use TIMI flow below 3 at the end of the procedure (Brosh 2007). The TIMI flow grade and the corrected TIMI frame count are described on the coronary angiography hub, and the tissue-level scales (myocardial blush grade and TIMI myocardial perfusion grade) under perfusion grades.
Angiographic no-reflow shows only part of the microvascular injury. Microvascular obstruction, which cardiac magnetic resonance imaging (MRI) can quantify, occurs in about 40% to 50% of patients undergoing PCI and more often in ST-elevation myocardial infarction (STEMI) (Brugaletta 2026). Suboptimal myocardial reperfusion persists in up to 60% of patients after timely primary PCI (Cenko 2026). Primary PCI as a whole is covered on the STEMI hub.
Mechanisms of no-reflow: embolization, microvascular obstruction, spasm, and reperfusion injury
Several mechanisms act together, in proportions that vary with the setting.
- Distal embolization. Balloon inflation, stent deployment, and atherectomy release thrombus, lipid-rich plaque, and cholesterol crystals into the microcirculation. Embolization dominates in STEMI with a large thrombus burden and in degenerated saphenous vein grafts.
- Microvascular vasoconstriction. Vasoactive substances released from platelets and injured endothelium constrict arterioles already partly blocked by debris. The prompt response of some no-reflow to intracoronary verapamil supports a spastic component (Piana 1994).
- Ischemia-reperfusion injury. Endothelial and myocyte swelling, neutrophil plugging, and intramyocardial hemorrhage compress capillaries from outside. This component grows with ischemic time and responds least to drugs.
A clinical consensus statement on coronary microvascular obstruction describes no-reflow as a heterogeneous phenomenon driven largely by microvascular obstruction and ischemia-reperfusion injury, and identifies it as a determinant of infarct healing, adverse remodeling, heart failure, and death (Cenko 2026).
Incidence and predictors of no-reflow
In the NCDR CathPCI Registry, no-reflow occurred in 2.3% of 291,380 patients with acute MI undergoing PCI of native arteries from 2004 to 2008. Independent clinical predictors were older age, STEMI, a longer interval from symptom onset to admission, and cardiogenic shock; angiographic predictors were longer lesions, ACC/AHA type C lesions, bifurcation lesions, and impaired TIMI flow before PCI (Harrison 2013). In a single-center primary PCI series of 599 patients, no-reflow occurred in 6.7%, most often (73%) after stenting. Patients with no-reflow were older, had longer ischemic times (5.5 against 4.4 hours), and more often had TIMI 0 or 1 flow at presentation (90% against 64%); kidney failure was an independent predictor (Brosh 2007).
In an early series of 1,919 interventions, no-reflow occurred in 2.0% (Piana 1994). The rate is far higher in degenerated saphenous vein grafts: in a prospective study of vein graft interventions with angioscopy and extraction atherectomy, no-flow (TIMI flow below 3 without a significant lesion or dissection) occurred in 15 of 36 lesions (42%) (Kaplan 1996). A heavy thrombus burden, long lesions, impaired flow before PCI, and vein graft disease increase the risk.
Microvascular obstruction beyond the angiogram: ST resolution, IMR, and cardiac MRI
ST-segment resolution. Persistent ST elevation after an angiographically successful primary PCI indicates failed tissue reperfusion. Resolution of more than 70% of the summed ST elevation 90 minutes after PCI is a standard end point of myocardial reperfusion in trials (Niccoli 2013).
Index of microcirculatory resistance. The index of microcirculatory resistance (IMR) is measured with a pressure-temperature wire during hyperemia. An IMR of 25 or more indicates microvascular dysfunction in patients without ACS. About half of patients with STEMI have an IMR above 25 after reperfusion, and an IMR above 40 has been associated with microvascular obstruction on MRI and with poor outcomes (Brugaletta 2026). In a pooled analysis of 1,265 patients from 6 cohorts with IMR measured immediately after primary PCI, cardiac death at 5 years occurred in 4.9% with an IMR above 40 and 2.2% with an IMR of 40 or less (hazard ratio 2.81). IMR independently predicted cardiac death, whereas coronary flow reserve did not; the optimal cutoff for cardiac death in that cohort was 70 (El Farissi 2023).
Cardiac MRI. Microvascular obstruction appears on late gadolinium enhancement as a dark core within the bright infarct. In a pooled analysis of 1,688 patients from 7 primary PCI trials imaged a median of 3 days after STEMI, microvascular obstruction was present in 56.9%. An absolute increase of 1% in its extent (as a percentage of left ventricular mass) raised the hazard of death by 14% and of heart failure hospitalization by 8% at 1 year. The association with death persisted after adjustment for infarct size (de Waha 2017). Microvascular obstruction on MRI increases over the first 48 hours, then declines and disappears by about 1 to 2 months (Brugaletta 2026). MRI technique and infarct quantification are on the cardiac MRI hub.
Treatment of no-reflow: sequence and intracoronary drug delivery
The first step is the exclusion of a mechanical cause, because the treatments differ. Guide-catheter damping, an occlusive dissection at the stent edge, thrombus within the stent, a distal embolic cutoff, epicardial spasm, and air all reduce flow; intracoronary nitroglycerin and orthogonal views separate them from microvascular no-reflow. Intravascular imaging confirms a patent, well-expanded stent when the angiogram is uncertain.
Once the epicardial artery is shown to be patent, the vasodilator is delivered into the distal bed. When flow is slow, drug injected through the guide catheter reaches the obstructed bed poorly; a microcatheter, an over-the-wire balloon, or an aspiration catheter advanced beyond the stent delivers the drug to the obstructed territory. The drug is chosen by blood pressure, heart rate, and conduction. Atrioventricular nodal blocking vasodilators carry particular risk with marked bradycardia or advanced conduction disease. Marked vasodilation is hazardous with hypotension, which itself reduces microvascular perfusion. Mean arterial pressure is supported, with an intra-aortic balloon pump or vasopressors when needed. Intracoronary epinephrine has been studied for no-reflow refractory to vasodilators (Ryabov 2024) and as first-line therapy in normotensive patients (Khan 2022).
Intracoronary nitroglycerin relieves epicardial spasm. In a prospective study of no-reflow during vein graft intervention, intragraft nitroglycerin (100 to 300 µg) did not improve TIMI flow, whereas intragraft verapamil (100 to 500 µg) improved flow in all 32 episodes and restored TIMI 3 flow in 88% (Kaplan 1996).
The pharmacology of the calcium channel blockers is on the calcium channel blocker hub.
| Drug | Intracoronary doses studied | Evidence | Principal cautions |
|---|---|---|---|
| Adenosine | Given distal to the occlusion after thrombus aspiration (REOPEN-AMI); 2–3 mg in total in divided doses (REFLO-STEMI) | REOPEN-AMI: ST resolution over 70% in 71% against 51% with saline. REFLO-STEMI: no reduction in infarct size or microvascular obstruction | Atrioventricular nodal block and bradycardia; adverse outcomes in the REFLO-STEMI per-protocol analysis |
| Sodium nitroprusside | 50–300 µg (Brugaletta 2026); 500 µg in total in REFLO-STEMI | Meta-analysis of 7 trials (781 patients): less TIMI flow of grade 2 or lower (relative risk 0.47); no reduction of microvascular obstruction in REFLO-STEMI or REOPEN-AMI | Hypotension |
| Verapamil | 50–900 µg in total in native arteries; 100–500 µg intragraft | Improved TIMI flow in 89% of no-reflow episodes; TIMI 3 in 88% of vein graft episodes | Bradycardia, atrioventricular block, hypotension, negative inotropy; pacing available |
| Nicardipine | Mean 460 ± 360 µg | TIMI 3 flow restored in 71 of 72 patients in a retrospective series | Hypotension; no adverse hemodynamic or chronotropic effects in the series |
| Epinephrine | Bolus as first-line therapy (COAR) or for no-reflow refractory to conventional therapy | COAR: final TIMI 3 flow 90.1% against 78% with adenosine; refractory STEMI trial: TIMI 3 flow 56% against 29% | Uncertain clinical benefit; no ventricular fibrillation in COAR |
| Glycoprotein IIb/IIIa inhibitor | Bolus at the labeled dose | Bailout for thrombus, slow flow, or no-reflow | Bleeding; stopped at once after perforation |
| Nitroglycerin | 100–300 µg | Relieves epicardial spasm; no effect on true no-reflow in vein grafts | Hypotension |
Intracoronary drugs for no-reflow, with the doses used in the cited studies (Niccoli 2013; Nazir 2016; Zhao 2014; Brugaletta 2026; Piana 1994; Kaplan 1996; Huang 2006; Khan 2022; Ryabov 2024; Cenko 2026). No dose is approved by the FDA for intracoronary use in no-reflow.
Intracoronary vasodilator trials: adenosine, nitroprusside, calcium channel blockers, and epinephrine
Adenosine. In REOPEN-AMI, 240 patients with STEMI and TIMI 0 or 1 flow were randomized after thrombus aspiration to adenosine, nitroprusside, or saline given distal to the occlusion. ST resolution over 70% occurred in 71% with adenosine, 54% with nitroprusside, and 51% with saline; angiographic microvascular obstruction (TIMI flow 2 or less, or TIMI 3 with blush grade below 2) occurred in 18%, 24%, and 30% (Niccoli 2013). REFLO-STEMI randomized 247 patients with single-vessel STEMI presenting within 6 hours to high-dose intracoronary adenosine (2 to 3 mg in total), nitroprusside (500 µg in total), or standard primary PCI. Neither drug reduced infarct size or microvascular obstruction on MRI, and, in the per-protocol analysis, adenosine was associated with larger infarcts, lower ejection fraction, and more major adverse cardiac events at 30 days and 6 months (Nazir 2016).
Nitroprusside. A meta-analysis of 7 trials and 781 patients undergoing primary PCI found that intracoronary nitroprusside reduced angiographic no-reflow (TIMI flow 2 or less; relative risk 0.47) and major adverse cardiac events (relative risk 0.43), with a nonsignificant trend in ST resolution (Zhao 2014). The largest trials, REOPEN-AMI and REFLO-STEMI, did not show a reduction in microvascular obstruction.
Calcium channel blockers. The evidence is observational. In a series of 1,919 interventions, intracoronary verapamil in total doses of 50 to 900 µg improved TIMI flow in 89% of no-reflow episodes and shortened the frame count from 91 to 38. In patients with a mechanical obstruction, it improved flow in only 19% (Piana 1994). Intracoronary nicardipine reversed no-reflow with TIMI 3 flow in 71 of 72 patients without adverse hemodynamic or chronotropic effects (Huang 2006).
Epinephrine. In the COAR trial, 201 normotensive patients with ACS and no-reflow were randomized to intracoronary epinephrine or adenosine as first-line therapy. Final TIMI 3 flow was more frequent with epinephrine (90.1% against 78%) and the corrected frame count lower (24 against 26.6). Blush grade 3, mortality, and major adverse cardiac events did not differ, and no ventricular fibrillation occurred (Khan 2022). In 90 patients with STEMI and no-reflow refractory to conventional therapy, intracoronary epinephrine restored TIMI 3 flow more often than conventional treatment alone (56% against 29%) and produced ST resolution over 50% more often (78% against 36%). It also reduced the extent of microvascular obstruction on MRI, without more life-threatening arrhythmia (Ryabov 2024).
The consensus statement concludes that intracoronary adenosine and nitroprusside have shown unclear benefit in improving microvascular flow (Cenko 2026). The vasodilators restore angiographic flow; whether that restoration changes infarct size or survival has not been demonstrated in a large trial.
Prevention of no-reflow: thrombus aspiration, glycoprotein IIb/IIIa inhibitors, direct and deferred stenting
Thrombus aspiration. Routine manual aspiration before primary PCI did not reduce mortality in TASTE (7,244 patients; death at 30 days 2.8% against 3.0%) (Fröbert 2013). In TOTAL (10,732 patients), it did not reduce the composite of cardiovascular death, recurrent MI, cardiogenic shock, or class IV heart failure (6.9% against 7.0%), and stroke at 30 days was more frequent with aspiration (0.7% against 0.3%) (Jolly 2015). Routine aspiration is not recommended, and selective aspiration is used for a large residual thrombus burden after flow is restored. The recommendation and trial detail are on the STEMI hub. The 2023 European Society of Cardiology (ESC) ACS guideline classifies routine aspiration as Class III (Level A) and allows selective use with a significant thrombus burden (Brugaletta 2026). An aspiration catheter also serves to deliver drugs distally.
Glycoprotein IIb/IIIa inhibitors. These are bailout agents for a large thrombus burden, slow flow, or no-reflow during PCI and are not given routinely; the US recommendation is on the NSTE-ACS hub. The 2023 ESC ACS guideline gives Class IIa (Level C) to their use when there is evidence of no-reflow or a thrombotic complication (Brugaletta 2026).
Direct stenting and deferred stenting. In primary PCI, small studies associate direct stenting with less no-reflow, and a meta-analysis of 3 small randomized trials suggests better procedural and clinical outcomes in STEMI. In elective PCI, direct stenting has shown no benefit (Brugaletta 2026). Deferred stenting restores flow, leaves the thrombus to resolve under antithrombotic therapy, and places the stent at a second procedure. In DANAMI-3-DEFER, 1,215 patients with STEMI were randomized to immediate stenting or stenting 48 hours later when stable flow had been obtained. The composite of death, heart failure hospitalization, recurrent MI, and target-vessel revascularization at a median of 42 months did not differ (18% against 17%; hazard ratio 0.99) (Kelbæk 2016). At 10 years, deferred stenting did not reduce death or the composite of death and heart failure hospitalization (hazard ratio 0.82; P = 0.08), although heart failure hospitalization alone was less frequent (odds ratio 0.58) (Marquard 2025). When TIMI flow 2 to 3 cannot be obtained before stenting, a published treatment algorithm includes deferral of the stent with glycoprotein IIb/IIIa inhibitor and heparin infusions for 24 to 48 hours (Brugaletta 2026).
Other adjuncts. In T-TIME, 440 patients presenting within 6 hours of STEMI were randomized to intracoronary alteplase 10 mg, alteplase 20 mg, or placebo, infused after reperfusion and before stent implantation. Low-dose alteplase did not reduce microvascular obstruction on cardiac MRI (3.5% of left ventricular mass with 20 mg against 2.3% with placebo) (McCartney 2019). Intracoronary supersaturated oxygen reduced infarct size in anterior STEMI in AMIHOT II and is approved by the FDA for delivery to the left anterior descending territory after PCI with stenting completed within 6 hours of the onset of anterior MI (Brugaletta 2026; FDA PMA P170027). Ischemic postconditioning, stent-retriever thrombectomy, and left ventricular unloading before reperfusion require validation in large trials (Cenko 2026).
Prognosis after no-reflow
No-reflow marks a larger infarct and a worse outcome. In the NCDR registry, in-hospital mortality was 12.6% with no-reflow and 3.8% without it (adjusted odds ratio 2.20), and lesion failure was 29.7% against 6.6% (Harrison 2013). In a primary PCI series, no-reflow was associated with higher peak creatine kinase, more moderate or severe left ventricular dysfunction (68% against 45%), and higher 6-month mortality (12.5% against 4.3%). No-reflow was an independent predictor of death (odds ratio 3.4) (Brosh 2007). On MRI, the extent of microvascular obstruction predicts death and heart failure hospitalization independently of infarct size (de Waha 2017), and an IMR above 40 after primary PCI predicts cardiac death at 5 years (El Farissi 2023).
Distal embolization of plaque and thrombus
Distal embolization is the passage of thrombus or atheromatous debris downstream during PCI, seen as abrupt cutoff of a distal branch, a filling defect, or slow flow. It is most frequent during PCI of thrombotic lesions in acute MI and of degenerated saphenous vein grafts, whose friable, lipid-rich plaque fragments readily. Stenting of vein graft lesions carried a 20% incidence of procedure-related complications before embolic protection, largely attributed to distal embolization (Baim 2002). Embolization produces periprocedural MI and no-reflow.
The response is aspiration of the embolus when it lodges in a vessel large enough to reach, a glycoprotein IIb/IIIa inhibitor for thrombus, distal vasodilators for the microvascular component, and support of perfusion pressure. Prevention depends on lesion selection. When a degenerated vein graft and its native target artery are both treatable, PCI of the native artery is prioritized whenever feasible. In a review of 26 observational studies with 366,060 patients after CABG, bypass graft PCI was associated with more short-term and long-term major adverse cardiac events than native artery PCI (Farag 2022). Graft angiography and graft failure are on the coronary angiography hub.
Embolic protection in saphenous vein graft PCI: distal occlusion, filters, and proximal occlusion
Embolic protection devices capture or aspirate debris released during vein graft PCI. The 2021 revascularization guideline classifies embolic protection in vein graft PCI as reasonable (Class 2a), downgraded from the Class 1 recommendation of earlier guidance (ACC 2022).
Distal occlusion and aspiration. A balloon on the wire is inflated beyond the lesion, the graft is stented while flow is arrested, and the stagnant column of blood and debris is aspirated before the balloon is deflated. In the SAFER trial, 801 patients undergoing vein graft stenting were randomized to this device or a conventional guidewire. Death, MI, emergency bypass, or target-lesion revascularization at 30 days occurred in 9.6% with protection and 16.5% without it, a 42% relative reduction driven by MI (8.6% against 14.7%) and no-reflow (3% against 9%). The benefit persisted in the 61% of patients who also received glycoprotein IIb/IIIa inhibitors (Baim 2002). The disadvantages are ischemia during occlusion and the need for a landing zone of normal graft beyond the lesion.
Distal filters. A filter basket on the wire is deployed beyond the lesion, preserving flow while capturing particles larger than its pores. In FIRE, 651 patients were randomized to a filter or the balloon occlusion and aspiration system. The 30-day composite of death, MI, or target-vessel revascularization was 9.9% with the filter and 11.6% with the occlusion device, meeting noninferiority (Stone 2003). Filters fail when the basket cannot cross the lesion, when no landing zone exists, or when debris overwhelms the basket and causes slow flow.
Proximal occlusion. A balloon on the guide occludes the graft proximal to the lesion, arresting antegrade flow before any device crosses the lesion; debris is aspirated before flow is restored. Proximal protection works with conventional guidewires and suits lesions near the distal anastomosis, where distal devices have no landing zone. In PROXIMAL, 594 patients were randomized to distal protection when possible or to proximal protection when possible. The 30-day composite of death, MI, or target-vessel revascularization was 10.0% with distal and 9.2% with proximal protection, meeting noninferiority; in lesions suitable for either approach, it was 12.2% with distal and 7.4% with proximal protection (Mauri 2007). Proximal occlusion requires a segment of graft proximal to the lesion for the occluding balloon.
| Device class | Principle | Trial | Result | Anatomic limits |
|---|---|---|---|---|
| Distal balloon occlusion and aspiration | Flow arrest beyond the lesion; aspiration of the stagnant column | SAFER (801 patients) | 30-day MACE 9.6% against 16.5% with no protection | Needs a distal landing zone; ischemia during occlusion |
| Distal filter | Basket captures particles; flow maintained | FIRE (651 patients) | 30-day MACE 9.9% against 11.6% with balloon occlusion; noninferior | Needs a distal landing zone; basket can fill and cause slow flow |
| Proximal occlusion | Flow arrest before the lesion is crossed; aspiration | PROXIMAL (594 patients) | 30-day MACE 9.2% against 10.0% with distal protection; noninferior | Needs a proximal segment of graft; unsuitable for ostial lesions |
Embolic protection devices for saphenous vein graft PCI (Baim 2002; Stone 2003; Mauri 2007). MACE, major adverse cardiac events, defined in the trials as composites of death, myocardial infarction, and repeat revascularization (with emergency bypass in SAFER).
Iatrogenic coronary dissection during PCI: mechanisms and management
Balloon angioplasty works by fracturing plaque, so a degree of dissection is part of the mechanism. Dissection becomes a complication when the tear extends into the media, the flap or false lumen compromises flow, or blood accumulates in the wall. There are three sources. The guide catheter tears the ostium or proximal vessel during deep or malaligned engagement and forceful injection. The guidewire enters the subintimal space, particularly in CTO PCI and in tortuous or diseased segments. The balloon or stent tears the vessel when oversized, inflated at high pressure, or expanded across a calcified segment, and the tear propagates from the edge of the stent into less diseased reference segments.
Angiographic severity is graded by the National Heart, Lung, and Blood Institute (NHLBI) classification into types A to F; the table of types is on the coronary angiography hub. In 691 dissections after balloon angioplasty, type B dissections did not increase morbidity or mortality, whereas types C to F were followed by acute closure in 31%, emergency bypass in 37%, MI in 13%, and repeat angioplasty in 24%, with clinical success in only 38% (Huber 1991). In the stent era, fewer patients needed emergency CABG for coronary dissection and abrupt vessel closure (Yang 2005).
Bailout stenting. A dissection that limits flow, a type C to F dissection, or one with a persisting false lumen or filling defect is covered with a stent from normal segment to normal segment. The wire is kept in the true lumen. When the wire is lost, the vessel is rewired and the true-lumen position is confirmed by intravascular imaging, because a stent deployed in a false lumen compresses the true lumen and closes the vessel. Small non-flow-limiting dissections (types A and B) beyond the stent can be observed.
Intramural hematoma. Blood can enter the media through a dissection with no re-entry and accumulate as a hematoma that compresses the lumen from outside. In an intravascular ultrasound study of 1,025 native coronary lesions, intramural hematoma followed 6.7% of PCIs; 46% involved the distal reference segment and 36% the proximal reference segment. On angiography, 60% looked like a dissection, 11% like a new stenosis, and 29% showed no significant abnormality. Non-Q-wave MI occurred in 26% of patients with a hematoma, with repeat revascularization and sudden death during the following year (Maehara 2002). An unexplained new narrowing at the stent edge or a fall in flow after a satisfactory result is imaged with intravascular ultrasound, which shows the hematoma behind the intima. A hematoma that compromises the lumen is treated with a stent covering the entry site.
Stent edge dissection. Dissection at the stent margin is assessed with intravascular imaging at the end of the procedure. In ILUMIEN IV, in which all 2,128 patients with a single treated lesion had final OCT, a proximal edge dissection was an independent predictor of 2-year target-lesion failure (hazard ratio 1.77) and of ischemia-driven target-lesion revascularization, together with a smaller minimal stent area (Landmesser 2024).
The angiographic and OCT features of spontaneous coronary artery dissection (SCAD), in which stenting propagates the hematoma, are on the SCAD hub; iatrogenic extension during angiography of a patient with SCAD is described there under angiography.
Catheter-induced aortocoronary dissection
A guide catheter can tear the coronary ostium, and the dissection can propagate retrograde into the sinus of Valsalva and the ascending aorta. In 43,143 catheterizations, coronary dissection extending into the aorta occurred in 0.02%; it was more common during treatment of acute MI (0.19% against 0.01%). Patients with limited aortic involvement were treated successfully by stenting the coronary entry point, whereas dissection extending more than 40 mm up the aorta from the coronary ostium required surgery (Dunning 2000). Incidence, predisposing factors (small ostium, ostial atheroma), precipitating factors (deep intubation, catheter malalignment, wedged injection), and mortality in a 76,104-procedure series are on the coronary angiography hub.
The extent of aortic involvement guides management.
| Aortic extent | Definition | Management in the series |
|---|---|---|
| Limited aortic involvement | Confined to the sinus or extending up the ascending aorta 40 mm or less from the coronary ostium | Stenting of the coronary entry point |
| Extensive aortic involvement | Extending more than 40 mm up the ascending aorta from the coronary ostium | Surgical repair |
Catheter-induced aortocoronary dissection by aortic extent, with the management reported in a series of 43,143 catheterizations (Dunning 2000).
Immediate disengagement of the catheter stops further contrast injection into the false lumen. The coronary artery is wired and the ostium stented to seal the entry point, and further contrast injection into the aortic root is minimized. Surgery is reserved for extensive or progressive aortic dissection and for hemodynamic instability. The surgical management of aortic dissection is on the acute aortic syndromes hub.
Abrupt vessel closure, side-branch occlusion, and periprocedural myocardial infarction
Abrupt vessel closure is the sudden occlusion of the treated artery during or soon after PCI, from dissection, thrombus, spasm, side-branch or plaque shift, or air. Before stents, it was the principal cause of emergency surgery. In 3,300 consecutive PCIs from 1994 to 2000, abrupt closure fell from 5.9% to 1.1% as the use of stents and glycoprotein IIb/IIIa inhibitors rose, and side-branch occlusion accounted for an increasing share of the closures that remained (9.0% of closures in 1995 against 28.0% in 2000) (Almeda 2002). The response is recrossing with a wire, imaging the mechanism, and stenting a dissection, aspirating or treating thrombus, or relieving spasm with nitroglycerin. Thrombotic closure of a stent within 24 hours of implantation is classified as acute stent thrombosis and treated as such.
Side-branch occlusion. Stenting across a bifurcation shifts plaque and the carina into the branch ostium. In the COBIS II registry, side-branch occlusion (TIMI flow below 3) occurred in 8.4% of 2,227 bifurcation lesions with a side branch of 2.3 mm or more after main-vessel stenting. Predictors were side-branch stenosis of 50% or more (odds ratio 2.34), proximal main-vessel stenosis of 50% or more (2.34), side-branch lesion length, and ACS (1.53). Flow returned spontaneously in 13.9% and after side-branch intervention in 55.1% but did not return in 31.0%; a jailed wire in the side branch was associated with flow recovery (74.8% against 57.8%). Cardiac death or MI was more frequent with side-branch occlusion (adjusted hazard ratio 2.34) (Hahn 2013). An important side branch is protected with a wire before main-vessel stenting.
Periprocedural myocardial infarction. Embolization, side-branch occlusion, and abrupt closure cause myocardial necrosis after PCI. The universal definition classifies PCI-related infarction as type 4a, with stent thrombosis as type 4b and restenosis as type 4c; the thresholds and the Fifth Universal Definition changes are on the troponin and type 2 myocardial infarction hub. An SCAI consensus document defines a "clinically relevant MI" after revascularization by biomarker thresholds linked to subsequent death or heart failure in clinical studies, in place of thresholds sensitive to small degrees of necrosis (Moussa 2013). Prevention of procedural infarction and colchicine before PCI are covered on the colchicine hub.
Coronary air embolism
Air enters the coronary circulation through an incompletely flushed manifold or catheter, during device exchange, or when a balloon ruptures. In 3,715 coronary angiograms and angioplasties at a teaching center, the overall incidence of air embolism was 0.27%. Significant air embolism occurred in 0.19% during the first months of training, and air embolism was more frequent during angioplasty than during diagnostic angiography (0.84% against 0.24%); no case was found at the end of training (Khan 1995). The manifestations range from a transient filling defect without symptoms to chest pain, ST elevation, hypotension, bradycardia, ventricular fibrillation, and arrest, depending on the volume of air and the size of the territory.
The treatment options are aspiration of the air through the guide or a catheter placed at the bubble, forceful injection of saline or blood to fragment and drive the air through the microcirculation, 100% oxygen to speed resorption, and supportive measures including an intra-aortic balloon pump, cardiopulmonary resuscitation, and defibrillation (Khan 1995).
Prevention depends on technique. The manifold and catheter are aspirated and flushed after insertion and after device exchanges, and the catheter is allowed to back-bleed before injection. The syringe is held tip down so that bubbles rise away from the catheter, and the system is kept closed during exchanges of balloons and stents through the hemostatic valve.
Coronary spasm during PCI
Wires, balloons, stents, and atherectomy devices provoke spasm of the treated vessel, which appears as smooth narrowing proximal or distal to the device and can mimic dissection, a new stenosis, or no-reflow. Intracoronary nitroglycerin reverses epicardial spasm and is given before a narrowing is treated as a fixed lesion. In the series that defined no-reflow during PCI, patients received intracoronary nitroglycerin first, and those with persisting no-reflow then received verapamil (Piana 1994). Spasm that persists after nitroglycerin and withdrawal of the wire is treated with intracoronary calcium channel blockers. Radial artery spasm and vasospastic angina are covered on the calcium channel blocker hub and the vasospastic angina hub.
Device entrapment, stent loss, and retrieval
Stent loss. A stent can be stripped from its delivery balloon in calcified or angulated anatomy, particularly when it is pulled back into the guide. In 11,773 PCIs with stents at one center, stent loss occurred in 0.32%, more often in calcified lesions and those with severe proximal angulation. Retrieval was attempted in 35 of 38 cases and succeeded in 30 (86%). The methods were a small balloon advanced through the stent, inflated, and withdrawn (45%), a loop snare (26%), biliary forceps (12%), a retained-fragment retriever (10%), twisting of 2 wires around the stent (5%), and a basket (2%). In 3 patients, the stent was crushed against the wall with another stent without an attempt at retrieval. Stent loss was associated with more transfusion (24% against 7%) and more emergency bypass surgery (5% against 0.4%), whereas no patient whose lost stent was crushed or deployed had a major cardiac complication (Brilakis 2005). A stent lost on the wire is left on the wire, which provides a rail for retrieval or deployment.
Burr entrapment. A rotational atherectomy burr can become lodged distal to a tight calcified lesion. In 3,195 patients treated with rotational atherectomy, burr entrapment occurred in 0.69%. Strong manual pullback extracted the burr in 91%, and balloon angioplasty at the entrapment site allowed withdrawal in the remainder; major adverse cardiac events occurred in 23%, tamponade needing pericardiocentesis in 9%, and no patient needed surgery or died in hospital (Morita 2023).
Entrapped guidewires, fractured wire tips, and retained device fragments are managed with the same tools, and surgical retrieval is needed when percutaneous techniques fail and the fragment threatens flow or embolization.
Complications of atherectomy and chronic total occlusion PCI
Atherectomy. Devices that ablate or remove tissue carry the highest rates of perforation. Perforation occurred in 1.3% of atherectomy and laser procedures against 0.1% of balloon angioplasty in the registry that defined perforation grades (Ellis 1994), and laser or rotational atherectomy remained an independent predictor of perforation in the NCDR registry (odds ratio 2.38) and of adverse events after perforation (odds ratio 2.5) (Nairooz 2020). The other characteristic complications are slow flow and no-reflow, burr entrapment, and dissection.
Chronic total occlusion PCI. CTO PCI has a different complication profile because of dissection and re-entry techniques, retrograde access through collaterals, and long procedures. In 10,454 CTO PCIs from a multicenter registry, perforation occurred in 4.9%, most often in the CTO target vessel (66%), and 47% arose from the retrograde approach. Technical success was lower in procedures with perforation (66% against 87%), and major adverse cardiovascular events were more frequent (18% against 1.3%) (Kostantinis 2022). In the NCDR registry, CTO PCI rose from 3% to 4% of PCI volume, and perforation during CTO PCI rose from 1.2% to 1.5% (Nairooz 2020). The other CTO-specific complications are collateral perforation, equipment entrapment, high radiation and contrast exposure, bleeding from dual arterial access, and donor-vessel dissection and thrombosis during retrograde work. Donor-vessel injury jeopardizes both the donor territory and the territory supplied through the collaterals. Predefined limits on contrast volume, radiation dose, and procedure time govern when a CTO procedure is stopped.
Stent thrombosis and in-stent restenosis: the two failures of the stented segment
Stent failure takes two forms. Stent thrombosis is thrombotic occlusion of the stent and presents abruptly, usually as STEMI, with high mortality. In-stent restenosis is gradual renarrowing of the stented segment by tissue growth and presents with recurrent angina or, less often, an ACS. The distinction shapes the urgency of care: suspected stent thrombosis is a reperfusion emergency, and suspected restenosis is evaluated electively with angiography and intravascular imaging. The SCAI consensus statement recommends image-guided stenting at the index procedure to reduce both, and strong consideration of intravascular imaging when either is encountered, because the mechanism determines the treatment (Klein 2023). The platelet biology that links stent thrombosis to dual antiplatelet therapy (DAPT) is on the DAPT hub.
Academic Research Consortium definitions of stent thrombosis
The ARC definitions were developed by academic research organizations in the United States and Europe, with representatives of the FDA and device manufacturers, to standardize end points in drug-eluting stent trials (Cutlip 2007). ARC-2 revised the clinical and angiographic end point definitions (Garcia-Garcia 2018). Stent thrombosis is classified by the certainty of the evidence and by the time from implantation.
| Category | Criteria |
|---|---|
| Definite, angiographic | Thrombus or thrombus-related occlusion originating in the stent or within 5 mm proximal or distal to it, with at least one of the following: acute ischemic symptoms at rest, new ischemic ECG changes, or a typical rise and fall of cardiac biomarkers |
| Definite, pathological | Recent thrombus in the stent at autopsy or in tissue retrieved by thrombectomy |
| Probable | Any unexplained death within 30 days of implantation; or MI with acute ischemia in the territory of the stent without angiographic confirmation and without another obvious cause |
| Possible | Any unexplained death from 30 days after implantation onward |
| Silent occlusion | Incidental angiographic occlusion of a stent without clinical signs or symptoms; not counted as stent thrombosis |
| Acute | 0 to 24 hours after implantation |
| Subacute | Over 24 hours to 30 days |
| Late | Over 30 days to 1 year |
| Very late | Over 1 year |
Academic Research Consortium classification of stent thrombosis by certainty of evidence and by timing (Cutlip 2007; Garcia-Garcia 2018). Acute and subacute stent thrombosis together form early stent thrombosis (0 to 30 days). Device trials commonly report definite or probable stent thrombosis as a safety end point. ECG, electrocardiogram; MI, myocardial infarction.
The probable and possible categories capture events in which angiography was not performed, so that deaths from stent thrombosis are not missed. They also include deaths from other causes, which makes definite stent thrombosis the most specific category. The universal definition of MI classifies stent thrombosis as type 4b infarction; the changes introduced by the Fifth Universal Definition are on the troponin hub.
ARC stent thrombosis classifier
The classifier applies the ARC certainty and timing criteria (Cutlip 2007; Garcia-Garcia 2018). One month is taken as 30.4375 days (365.25 divided by 12) and 1 year as 365.25 days; an event at exactly 24 hours is acute and an event at exactly 30 days is subacute.
Stent thrombosis: incidence, timing, risk factors, and outcome
With current drug-eluting stents, definite or probable stent thrombosis occurs in about 0.5% of PCIs in registries; the 30-day mortality approaches 25%, and mortality after the event exceeds 30% at 10 years (Flowers 2025). In ILUMIEN IV, in which all patients had final OCT, the 2-year rate was 0.9% (Landmesser 2024). Earlier series in the era of bare-metal and first-generation drug-eluting stents reported higher rates. In the Dutch Stent Thrombosis Registry, 437 of 21,009 patients (2.1%) had definite stent thrombosis: 140 acute, 180 subacute, 58 late, and 59 very late (van Werkum 2009). Most stent thromboses therefore occur in the first 30 days.
Stent thrombosis presents as STEMI in most patients. In 106 consecutive patients with angiographically proven stent thrombosis, 78.3% presented with STEMI, and 78.3% were taking DAPT at the time of the event. In-hospital mortality was 17.9%, 1-year mortality 23.8%, and mortality at a mean of 65 months 35.6%; recurrent definite stent thrombosis occurred in 10.9% during follow-up. Cardiogenic shock, kidney failure, and the TIMI flow grade after intervention were independent predictors of death or recurrent thrombosis (Almalla 2013).
The risk factors fall into four groups.
- Procedural factors. Stent undersizing, residual dissection, TIMI flow below 3 at the end of the procedure, bifurcation lesions, and intermediate disease proximal and distal to the stent were associated with stent thrombosis in the Dutch registry (van Werkum 2009). In ILUMIEN IV, smaller minimal stent expansion on final OCT was the independent predictor of stent thrombosis (Landmesser 2024).
- Antiplatelet therapy. The absence of clopidogrel therapy at the time of the event was the strongest predictor in the Dutch registry: hazard ratio 36.5 in the first 30 days, 4.6 from 30 days to 6 months, and 5.9 beyond 6 months (van Werkum 2009). In PARIS, the reason for stopping DAPT determined its risk. Physician-recommended discontinuation was not associated with excess risk, whereas disruption from nonadherence or bleeding increased major adverse cardiac events (hazard ratio 1.50), with the highest risk in the first 7 days after disruption (hazard ratio 7.04) (Mehran 2013). High platelet reactivity on clopidogrel predicted stent thrombosis in a cohort of 804 patients (8.6% in nonresponders against 2.3% in responders; hazard ratio 3.08) (Buonamici 2007).
- Patient factors. Malignancy, ejection fraction below 30%, younger age, and STEMI at the index procedure are associated with stent thrombosis (van Werkum 2009; Buonamici 2007).
- Late biology. Very late stent thrombosis is associated with neoatherosclerosis, malapposition, and uncovered struts (Souteyrand 2016; Joner 2018).
Allergic stent thrombosis (Kounis syndrome type III) is covered on the toxicology hub, and stent thrombosis after omission of aspirin in patients taking oral anticoagulants on the atrial fibrillation and PCI hub.
Mechanisms of stent thrombosis on intravascular imaging
Angiography shows the occlusion; intravascular imaging shows why it happened. In the French PESTO registry of 120 patients with confirmed stent thrombosis imaged with OCT, an underlying abnormality was found in 97%: strut malapposition in 34%, neoatherosclerosis in 22%, major underexpansion in 11%, coronary evagination in 8%, isolated uncovered struts in 8%, edge-related disease progression in 8%, and neointimal hyperplasia in 4%. Acute and subacute thrombosis was related mainly to malapposition (48%) and underexpansion (26%), and late and very late thrombosis to malapposition (31%) and neoatherosclerosis (28%) (Souteyrand 2016).
In the PRESTIGE consortium, 134 patients with very late stent thrombosis were imaged with OCT. Rupture of neoatherosclerotic plaque inside the stent was the most frequent cause overall (31%) and the cause in 69% of patients with neoatherosclerosis, whereas uncovered struts were the most frequent cause in patients without it (29%) (Joner 2018). Imaging after flow is restored therefore separates the mechanical causes, which are corrected with balloons or stents during the procedure, from the biological ones.
| Mechanism | Imaging appearance | Typical timing | Correction |
|---|---|---|---|
| Underexpansion | Minimal stent area well below the reference lumen | Acute and subacute | High-pressure noncompliant balloon; lesion modification when calcium prevents expansion |
| Malapposition | Struts separated from the vessel wall with blood behind them | All periods | Balloon sized to the vessel to appose the struts |
| Edge dissection or edge disease | Flap, hematoma, or plaque at the stent margin | Acute (dissection), late (progression) | Additional stent to cover the segment |
| Uncovered struts | Struts without tissue coverage long after implantation | Late and very late | Antiplatelet therapy review |
| Neoatherosclerosis with rupture | Lipid-laden neointima with a ruptured cap and thrombus | Very late | Treatment as a new plaque rupture |
| Coronary evagination | Outward bulging of the wall between struts | More frequent after drug-eluting stents (12% against 2% after bare-metal stents) | Treatment of the associated thrombus |
Mechanisms of stent thrombosis on optical coherence tomography and their correction (Souteyrand 2016; Joner 2018; Klein 2023).
Management of stent thrombosis: emergency PCI, intravascular imaging, and antiplatelet review
Stent thrombosis presenting as STEMI is managed as STEMI: emergency angiography and primary PCI, with the STEMI system of care described on the STEMI hub. The procedure has several aims.
- Restoration of flow. Prompt PCI that restores coronary flow is the cornerstone of treatment (Cecchi 2026). The thrombosed stent is crossed with a wire and dilated with a balloon. As in primary PCI, aspiration thrombectomy is used selectively for a large thrombus burden, and a glycoprotein IIb/IIIa inhibitor is used for a thrombotic complication or no-reflow (Brugaletta 2026).
- Identification of the mechanism. IVUS or OCT after flow is restored defines underexpansion, malapposition, edge dissection or disease, neoatherosclerosis, or uncovered struts (Souteyrand 2016; Klein 2023).
- Correction of the mechanism. Underexpansion and malapposition are treated with high-pressure balloon dilation sized to the vessel, edge problems with an additional stent, and neoatherosclerotic rupture as a new plaque rupture. A new stent is avoided when the cause is a correctable mechanical problem of the existing stent.
- Antiplatelet review. Adherence, interruption for surgery or bleeding, drug interactions, and absorption are reviewed. High on-treatment platelet reactivity with clopidogrel predicts stent thrombosis (Buonamici 2007), and platelet function testing can identify it. The choice of P2Y12 inhibitor and switching between agents are on the DAPT hub.
Recurrent stent thrombosis occurred in 10.9% of patients during long-term follow-up in one series (Almalla 2013), so the mechanism and antiplatelet regimen are both addressed before discharge.
Bioresorbable scaffold thrombosis
Bioresorbable vascular scaffolds were designed to dissolve after supporting the vessel, leaving no permanent metal. In AIDA, 1,845 patients undergoing routine PCI were randomized to an everolimus-eluting bioresorbable scaffold or an everolimus-eluting metallic stent. Target-vessel failure did not differ at 2 years (11.7% against 10.7%). Definite or probable device thrombosis occurred in 3.5% with the scaffold and 0.9% with the metallic stent (hazard ratio 3.87), and the data and safety monitoring board recommended early reporting because of safety concerns (Wykrzykowska 2017).
In-stent restenosis: definition, incidence, and mechanisms
In-stent restenosis is renarrowing of the stented segment by tissue growth inside the stent or at its edges. Trials measure it angiographically and clinically, as ischemia-driven target-lesion revascularization.
Drug-eluting stents reduced restenosis substantially. In SIRIUS, 1,058 patients with complex native lesions were randomized to a sirolimus-eluting or a bare-metal stent; target-lesion revascularization at 270 days fell from 16.6% to 4.1%, and target-vessel failure from 21.0% to 8.6% (Moses 2003). Because the number of patients with stents has grown, restenosis remains a large clinical problem. In the NCDR CathPCI Registry from 2009 to 2017, 10.6% of 5,100,394 PCIs treated in-stent restenosis. Restenosis of bare-metal stents declined from 2.6% to 0.9% of PCIs, while restenosis of drug-eluting stents rose from 5.4% to 6.3%. About 25% of patients with restenosis presented with acute MI, and restenosis was treated most often with another stent (Moussa 2020).
The mechanisms are biological and mechanical.
- Neointimal hyperplasia. Proliferating smooth muscle cells and extracellular matrix accumulate within the struts, typically in the first year after implantation. Diabetes is associated with more extensive patterns and more recurrence (Mehran 1999).
- Neoatherosclerosis. Lipid-laden foamy macrophages accumulate within the neointima and can form a necrotic core and a thin-cap fibroatheroma. In 299 autopsies with 406 stented lesions, neoatherosclerosis was found in 31% of drug-eluting stents against 16% of bare-metal stents, and it appeared earlier with drug-eluting stents (median 420 against 2,160 days) (Nakazawa 2011). Neoatherosclerosis causes late restenosis and very late stent thrombosis.
- Underexpansion. A stent that never reached its intended area restricts the lumen from the day of implantation. It is a mechanical problem that drugs on a balloon or a second stent do not correct.
- Stent fracture and edge injury. Fracture of the struts and disease at untreated or injured edges cause focal restenosis.
Angiographic patterns of in-stent restenosis
The angiographic classification of in-stent restenosis (ISR) describes the distribution of intimal hyperplasia relative to the stent. It was developed in 288 lesions in 245 patients and validated with intravascular ultrasound (Mehran 1999). The pattern predicts recurrence after treatment.
| Pattern | Definition | Frequency | Prior recurrent ISR | Target-lesion revascularization after treatment |
|---|---|---|---|---|
| I, focal | Lesion 10 mm or shorter | 42% | 9% | 19% |
| II, diffuse intrastent | Over 10 mm, confined to the stent | 21% | 20% | 35% |
| III, diffuse proliferative | Over 10 mm, extending beyond the stent edges | 30% | 34% | 50% |
| IV, occlusive | Total occlusion of the stent | 7% | 50% | 83% |
Angiographic patterns of in-stent restenosis (ISR) after bare-metal stenting, with their frequency, the proportion with previously recurrent ISR, and target-lesion revascularization after treatment (Mehran 1999). Diabetes, previously recurrent ISR, and the ISR class were independent predictors of repeat revascularization.
The SCAI consensus statement proposed a new classification of in-stent restenosis that incorporates time from implantation and mechanism, because the timing of restenosis carries mechanistic implications (Klein 2023). Multilayer restenosis, within 2 or more layers of stent, carries higher rates of recurrence: in AGENT IDE, 44% of patients had multilayer restenosis, and their target-lesion failure at 1 year was 29.0% against 15.7% with single-layer restenosis (Kirtane 2025).
Stent fracture
Stent fracture is a complete or partial separation of stent struts. In a meta-analysis of 46 studies, the incidence of coronary drug-eluting stent fracture was 5.5% of patients, 4.8% of lesions, and 4.9% of stents; the reported incidence has risen over 20 years, and it was influenced by stent type and location in the right coronary artery (Chen 2022). An earlier meta-analysis of 8 studies (5,321 patients) found fracture mostly with sirolimus-eluting stents and in the right coronary artery (56.4% of fractures). Fracture was more frequent with overlapping stents (7.5% against 2.1%) and long stents (mean 46 against 32.5 mm). Fractured segments had more restenosis (38% against 8.2%) and target-lesion revascularization (17% against 5.6%), and fracture was more frequent in lesions with restenosis (12.8% against 2.1%) (Chakravarty 2010). Fracture is seen on fluoroscopy or enhanced stent visualization as a gap or displacement of struts and is confirmed with intravascular imaging.
Treatment of in-stent restenosis: intravascular imaging, drug-coated balloons, repeat stenting, and brachytherapy
Treatment begins with the mechanism. Intravascular imaging distinguishes underexpansion, which needs high-pressure dilation or modification of the calcium behind the stent, from neointimal hyperplasia or neoatherosclerosis, which needs an antiproliferative drug (Klein 2023). Imaging also defines the number of stent layers and the vessel size.
Underexpansion. Noncompliant balloons at high pressure expand most underexpanded stents. When calcium behind the stent prevents expansion, intravascular lithotripsy and other lesion-modification devices are used. In the IVL-DRAGON registry of 62 patients, intravascular lithotripsy increased stent expansion on OCT from 37.5% to 86.0% and achieved a relative expansion over 80% in 72.6% of patients, with 1 cardiac death at 30 days (Wańha 2022). The use of lithotripsy inside stents is off label.
Drug-coated balloon. A paclitaxel-coated balloon delivers drug to the neointima without adding a metal layer. In AGENT IDE, the first US trial of a coronary drug-coated balloon, 600 patients with restenosis (lesion length below 26 mm, vessel diameter over 2.0 mm and up to 4.0 mm) were randomized 2:1 to a paclitaxel-coated or uncoated balloon. Target-lesion failure at 1 year was 17.9% against 28.6% (hazard ratio 0.59), driven by target-lesion revascularization (13.0% against 24.7%) and target-vessel MI (5.8% against 11.1%), without a significant difference in cardiac death (2.9% against 1.6%) (Yeh 2024).
Repeat drug-eluting stent. In DAEDALUS, a pooled analysis of individual patient data from all 10 randomized trials comparing drug-coated balloon angioplasty with repeat drug-eluting stenting for restenosis, the two treatments were similar for bare-metal stent restenosis. For drug-eluting stent restenosis, target-lesion revascularization at 3 years was higher with the drug-coated balloon (20.3% against 13.4%; hazard ratio 1.58), and the composite of death, MI, or target-lesion thrombosis was numerically lower (9.5% against 13.3%; hazard ratio 0.69). Target-lesion revascularization was lower after bare-metal than after drug-eluting stent restenosis, whichever treatment was used (9.7% against 17.0%) (Giacoppo 2020). A repeat drug-eluting stent is the more effective treatment for drug-eluting stent restenosis, and a drug-coated balloon avoids another layer of metal. In the multilayer subgroup of AGENT IDE, target-lesion failure was 23.8% with the paclitaxel-coated balloon against 40.0% with an uncoated balloon (hazard ratio 0.55) (Kirtane 2025).
Intravascular brachytherapy. Beta radiation delivered within the stent suppresses neointimal proliferation. In a meta-analysis of 5 studies (1,375 patients), drug-eluting stents reduced target-lesion revascularization at 2 to 5 years compared with brachytherapy (odds ratio for brachytherapy 2.37), without differences in MI, stent thrombosis, or mortality (Benjo 2016). Brachytherapy remains in use for recurrent drug-eluting stent restenosis: in a multicenter series of 101 patients with a mean of 1.9 stent layers, target-lesion revascularization at 1 year was 10.9% (Bali 2025).
CABG. Recurrent diffuse restenosis in a large territory is a reason for heart team review of surgical revascularization.
| Treatment | Best use | Evidence | Limitations |
|---|---|---|---|
| Noncompliant balloon, lithotripsy | Underexpanded stent | IVL-DRAGON: expansion 37.5% to 86.0% on OCT | Off-label inside stents; observational evidence |
| Paclitaxel-coated balloon | Restenosis in vessels over 2.0 mm and up to 4.0 mm, including multilayer restenosis | AGENT IDE: TLF 17.9% against 28.6% with uncoated balloon | Less effective than repeat DES for DES restenosis |
| Repeat drug-eluting stent | DES restenosis without many prior layers | DAEDALUS: TLR 13.4% against 20.3% with drug-coated balloon at 3 years | Adds a metal layer |
| Intravascular brachytherapy | Recurrent multilayer restenosis | Meta-analysis: more TLR than DES at 2 to 5 years; TLR 10.9% at 1 year in a multilayer series | Observational data in the drug-eluting stent era |
| CABG | Recurrent diffuse restenosis in a large territory | Heart team decision | Surgical risk |
Treatment of in-stent restenosis (Klein 2023; Wańha 2022; Yeh 2024; Kirtane 2025; Giacoppo 2020; Benjo 2016; Bali 2025). DES, drug-eluting stent; OCT, optical coherence tomography; TLF, target-lesion failure; TLR, target-lesion revascularization.
Systemic complications after PCI: stroke, kidney injury, bleeding, and access-site injury
Stroke. In 4,910,430 PCIs in a nationwide German cohort from 2006 to 2021, acute ischemic stroke occurred in 0.08%, and its incidence rose over the period. In-hospital mortality was 18.11% with stroke against 3.29% without it. Carotid disease, prior stroke, atrial fibrillation, presentation with MI, and coronary thrombectomy were the strongest associations (Bay 2024). A focal deficit during or after PCI is a stroke alert with immediate brain imaging; the management of procedural stroke is on the cardioembolic stroke hub.
Contrast-associated kidney injury. Acute kidney injury after PCI and its prevention are covered on the contrast hub.
Bleeding and access-site complications. Radial access reduces bleeding, vascular complications, and death in ACS compared with femoral access; the trial evidence is on the STEMI hub. Retroperitoneal hemorrhage, pseudoaneurysm, arteriovenous fistula, and radial artery occlusion are described on the coronary angiography hub, and the bleeding scales used in PCI trials, including the Bleeding Academic Research Consortium (BARC) classification, are on the DAPT hub.
Sources of error in managing PCI complications
- Attributing hypotension during or after PCI to vagal tone or sedation without echocardiography for tamponade and imaging for retroperitoneal bleeding.
- Withdrawing the guidewire from a dissected or perforated artery before the complication is controlled.
- Delaying balloon occlusion of a grade III perforation while the covered stent is prepared.
- Reversing heparin with protamine while a fresh stent, wire, and guide remain in an artery that still needs treatment, or giving protamine rapidly.
- Continuing a glycoprotein IIb/IIIa inhibitor infusion after a perforation is recognized.
- Discharging a patient after a grade I or II perforation without repeat echocardiography, although late tamponade carries the same mortality as acute tamponade.
- Choosing a covered stent for a distal wire perforation that only embolization can reach, or embolizing a large vessel whose perforation a covered stent could seal.
- Treating no-reflow with vasodilators before excluding dissection, thrombus, spasm, guide damping, or residual stenosis.
- Injecting vasodilators through the guide catheter into a slow-flow artery when a microcatheter or aspiration catheter could deliver them distally.
- Giving verapamil or adenosine to a patient with marked bradycardia or heart block without pacing available, or nitroprusside to a hypotensive patient.
- Relying on intracoronary nitroglycerin to reverse microvascular no-reflow.
- Performing routine thrombus aspiration in primary PCI, which has not reduced mortality and was associated with stroke in TOTAL.
- Intervening on a degenerated vein graft without considering the native artery, or without embolic protection when the anatomy allows it.
- Stenting a dissection without confirming that the wire is in the true lumen.
- Repeating contrast injection through a catheter that has caused an ostial dissection.
- Stenting a spontaneous coronary artery dissection as if it were an iatrogenic flap.
- Flushing a manifold incompletely or allowing air into the system during device exchange.
- Forcing stent delivery or withdrawal through calcified, angulated segments, where stent loss is most frequent.
- Classifying an incidental stent occlusion without symptoms as stent thrombosis, or an unexplained late death as definite stent thrombosis.
- Treating stent thrombosis with a new stent before imaging has excluded underexpansion or malapposition of the existing stent.
- Omitting review of antiplatelet adherence, interruption, and response after stent thrombosis.
- Placing a second stent inside an underexpanded stent without first expanding it.
- Treating drug-eluting stent restenosis by plain balloon angioplasty alone.
- Choosing among treatments for restenosis without intravascular imaging to define its mechanism.
References
- Lawton JS, Tamis-Holland JE, Bangalore S, et al. 2021 ACC/AHA/SCAI guideline for coronary artery revascularization: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2022;79:e21–e129 (corrections: J Am Coll Cardiol 2022;79:1547 and 2024;84:771). doi:10.1016/j.jacc.2021.09.006
- Rao SV, O'Donoghue ML, Ruel M, et al. 2025 ACC/AHA/ACEP/NAEMSP/SCAI guideline for the management of patients with acute coronary syndromes: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2025;151:e771–e862 (corrections: Circulation 2025;151:e865, 151:e1098, and 152:e402). doi:10.1161/CIR.0000000000001309
- American College of Cardiology. Key takeaways from the 2021 coronary revascularization guidelines. ACC.org Latest in Cardiology. 2022. acc.org
- Cutlip DE, Windecker S, Mehran R, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344–2351. doi:10.1161/CIRCULATIONAHA.106.685313
- Garcia-Garcia HM, McFadden EP, Farb A, et al. Standardized end point definitions for coronary intervention trials: the Academic Research Consortium-2 consensus document. Circulation. 2018;137:2635–2650. doi:10.1161/CIRCULATIONAHA.117.029289
- Klein LW, Nathan S, Maehara A, et al. SCAI expert consensus statement on management of in-stent restenosis and stent thrombosis. J Soc Cardiovasc Angiogr Interv. 2023;2:100971. doi:10.1016/j.jscai.2023.100971
- Nairooz R, Parzynski CS, Curtis JP, et al. Contemporary trends, predictors and outcomes of perforation during percutaneous coronary intervention (from the NCDR Cath PCI Registry). Am J Cardiol. 2020;130:37–45. doi:10.1016/j.amjcard.2020.06.014
- Harrison RW, Aggarwal A, Ou FS, et al. Incidence and outcomes of no-reflow phenomenon during percutaneous coronary intervention among patients with acute myocardial infarction. Am J Cardiol. 2013;111:178–184. doi:10.1016/j.amjcard.2012.09.015
- Yang EH, Gumina RJ, Lennon RJ, et al. Emergency coronary artery bypass surgery for percutaneous coronary interventions: changes in the incidence, clinical characteristics, and indications from 1979 to 2003. J Am Coll Cardiol. 2005;46:2004–2009. doi:10.1016/j.jacc.2005.06.083
- Pancholy SB, Patel GA, Patel NR, et al. Trends, outcomes, and predictive score for emergency coronary artery bypass graft surgery after elective percutaneous coronary intervention (from a nationwide dataset). Am J Cardiol. 2021;144:46–51. doi:10.1016/j.amjcard.2020.12.060
- Castro-Dominguez YS, Wang Y, Minges KE, et al. Predicting in-hospital mortality in patients undergoing percutaneous coronary intervention. J Am Coll Cardiol. 2021;78:216–229. doi:10.1016/j.jacc.2021.04.067
- Doll JA, Hira RS, Kearney KE, et al. A practical approach to the management of complications during percutaneous coronary intervention. JACC Cardiovasc Interv. 2018;11:1797–1810. doi:10.1016/j.jcin.2018.05.052
- Mikhail P, Howden N, Monjur M, et al. Coronary perforation incidence, outcomes and temporal trends (COPIT): a systematic review and meta-analysis. Open Heart. 2022;9:e002076. doi:10.1136/openhrt-2022-002076
- Shimony A, Joseph L, Mottillo S, Eisenberg MJ. Coronary artery perforation during percutaneous coronary intervention: a systematic review and meta-analysis. Can J Cardiol. 2011;27:843–850. doi:10.1016/j.cjca.2011.04.014
- Ellis SG, Ajluni S, Arnold AZ, et al. Increased coronary perforation in the new device era: incidence, classification, management, and outcome. Circulation. 1994;90:2725–2730. doi:10.1161/01.cir.90.6.2725
- Harnek J, James S, Lagerqvist B. Coronary artery perforation and tamponade: incidence, risk factors, predictors and outcomes from 12 years' data of the SCAAR registry. Circ J. 2019;84:43–53. doi:10.1253/circj.CJ-19-0757
- Kostantinis S, Simsek B, Karacsonyi J, et al. Incidence, mechanisms, treatment, and outcomes of coronary artery perforation during chronic total occlusion percutaneous coronary intervention. Am J Cardiol. 2022;182:17–24. doi:10.1016/j.amjcard.2022.07.004
- US Food and Drug Administration. Humanitarian device exemption H000001: Jomed Jostent coronary stent graft (Abbott Vascular Devices). Decision date January 10, 2001. accessdata.fda.gov
- US Food and Drug Administration. Humanitarian device exemption H170004: PK Papyrus covered coronary stent system (Biotronik AG). Decision date September 14, 2018. accessdata.fda.gov
- Bartuś J, Januszek R, Hudziak D, et al. Clinical outcomes following large vessel coronary artery perforation treated with covered stent implantation: comparison between polytetrafluoroethylene- and polyurethane-covered stents (CRACK-II registry). J Clin Med. 2021;10:5441. doi:10.3390/jcm10225441
- Röther J, Tröbs M, Ludwig J, et al. Treatment and outcome of coronary artery perforations using a dual guiding catheter technique. Int J Cardiol. 2015;201:479–483. doi:10.1016/j.ijcard.2015.08.138
- Shemisa K, Karatasakis A, Brilakis ES. Management of guidewire-induced distal coronary perforation using autologous fat particles versus coil embolization. Catheter Cardiovasc Interv. 2017;89:253–258. doi:10.1002/ccd.26542
- Fischell TA, Moualla SK, Mannem SR. Intracoronary thrombin injection using a microcatheter to treat guidewire-induced coronary artery perforation. Cardiovasc Revasc Med. 2011;12:329–333. doi:10.1016/j.carrev.2010.12.002
- Hashemi A, Serati A, Ahmadieh A, et al. High success rate in sealing distal coronary artery perforations using absorbable gelatin sponge. Int J Angiol. 2026;35:130–135 (published online 2024). doi:10.1055/s-0044-1800856
- Fresenius Kabi USA. Protamine sulfate injection, USP: prescribing information. DailyMed, US National Library of Medicine. dailymed.nlm.nih.gov
- Accord Healthcare. Bivalirudin for injection: prescribing information. DailyMed, US National Library of Medicine. dailymed.nlm.nih.gov
- Baxter Healthcare. Eptifibatide injection: prescribing information. DailyMed, US National Library of Medicine. dailymed.nlm.nih.gov
- Brosh D, Assali AR, Mager A, et al. Effect of no-reflow during primary percutaneous coronary intervention for acute myocardial infarction on six-month mortality. Am J Cardiol. 2007;99:442–445. doi:10.1016/j.amjcard.2006.08.054
- Brugaletta S, Ortega-Paz L, Gómez-Lara J, et al. Slow flow and no reflow after percutaneous coronary intervention. EuroIntervention. 2026;22:e473–e488. doi:10.4244/EIJ-D-25-01346
- Cenko E, Badimon L, Vadalà G, et al. Pathophysiology, prevention, and management of coronary microvascular obstruction. Eur Heart J. 2026;47:4215–4241 (correction: Eur Heart J 2026;ehag897). doi:10.1093/eurheartj/ehag334
- Piana RN, Paik GY, Moscucci M, et al. Incidence and treatment of 'no-reflow' after percutaneous coronary intervention. Circulation. 1994;89:2514–2518. doi:10.1161/01.cir.89.6.2514
- Kaplan BM, Benzuly KH, Kinn JW, et al. Treatment of no-reflow in degenerated saphenous vein graft interventions: comparison of intracoronary verapamil and nitroglycerin. Cathet Cardiovasc Diagn. 1996;39:113–118. doi:10.1002/(SICI)1097-0304(199610)39:2<113::AID-CCD1>3.0.CO;2-I
- Niccoli G, Rigattieri S, De Vita MR, et al. Open-label, randomized, placebo-controlled evaluation of intracoronary adenosine or nitroprusside after thrombus aspiration during primary percutaneous coronary intervention for the prevention of microvascular obstruction in acute myocardial infarction: the REOPEN-AMI study. JACC Cardiovasc Interv. 2013;6:580–589. doi:10.1016/j.jcin.2013.02.009
- El Farissi M, Zimmermann FM, De Maria GL, et al. The index of microcirculatory resistance after primary PCI: a pooled analysis of individual patient data. JACC Cardiovasc Interv. 2023;16:2383–2392. doi:10.1016/j.jcin.2023.08.030
- de Waha S, Patel MR, Granger CB, et al. Relationship between microvascular obstruction and adverse events following primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: an individual patient data pooled analysis from seven randomized trials. Eur Heart J. 2017;38:3502–3510. doi:10.1093/eurheartj/ehx414
- Ryabov V, Dil S, Vyshlov E, et al. Efficiency and safety of intracoronary epinephrine administration in patients with ST-elevation myocardial infarction with refractory coronary no-reflow. Am J Cardiol. 2024;226:118–127. doi:10.1016/j.amjcard.2024.07.011
- Khan KA, Qamar N, Saghir T, et al. Comparison of intracoronary epinephrine and adenosine for no-reflow in normotensive patients with acute coronary syndrome (COAR trial). Circ Cardiovasc Interv. 2022;15:e011408. doi:10.1161/CIRCINTERVENTIONS.121.011408
- Nazir SA, McCann GP, Greenwood JP, et al. Strategies to attenuate micro-vascular obstruction during P-PCI: the randomized reperfusion facilitated by local adjunctive therapy in ST-elevation myocardial infarction trial. Eur Heart J. 2016;37:1910–1919. doi:10.1093/eurheartj/ehw136
- Zhao S, Qi G, Tian W, et al. Effect of intracoronary nitroprusside in preventing no reflow phenomenon during primary percutaneous coronary intervention: a meta-analysis. J Interv Cardiol. 2014;27:356–364. doi:10.1111/joic.12133
- Huang RI, Patel P, Walinsky P, et al. Efficacy of intracoronary nicardipine in the treatment of no-reflow during percutaneous coronary intervention. Catheter Cardiovasc Interv. 2006;68:671–676. doi:10.1002/ccd.20885
- Fröbert O, Lagerqvist B, Olivecrona GK, et al. Thrombus aspiration during ST-segment elevation myocardial infarction. N Engl J Med. 2013;369:1587–1597 (correction: N Engl J Med 2014;371:786). doi:10.1056/NEJMoa1308789
- Jolly SS, Cairns JA, Yusuf S, et al. Randomized trial of primary PCI with or without routine manual thrombectomy. N Engl J Med. 2015;372:1389–1398. doi:10.1056/NEJMoa1415098
- Kelbæk H, Høfsten DE, Køber L, et al. Deferred versus conventional stent implantation in patients with ST-segment elevation myocardial infarction (DANAMI 3-DEFER): an open-label, randomised controlled trial. Lancet. 2016;387:2199–2206. doi:10.1016/S0140-6736(16)30072-1
- Marquard JM, Engstrøm T, Kelbæk H, et al. 10-year outcomes of deferred or conventional stent implantation in patients with STEMI (DANAMI-3-DEFER). Circ Cardiovasc Interv. 2025;18:e015369. doi:10.1161/CIRCINTERVENTIONS.125.015369
- Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts (SAFER). Circulation. 2002;105:1285–1290. PMID 11901037
- Stone GW, Rogers C, Hermiller J, et al. Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts (FIRE). Circulation. 2003;108:548–553. doi:10.1161/01.CIR.0000080894.51311.0A
- Mauri L, Cox D, Hermiller J, et al. The PROXIMAL trial: proximal protection during saphenous vein graft intervention using the Proxis Embolic Protection System: a randomized, prospective, multicenter clinical trial. J Am Coll Cardiol. 2007;50:1442–1449. doi:10.1016/j.jacc.2007.06.039
- Huber MS, Mooney JF, Madison J, Mooney MR. Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. Am J Cardiol. 1991;68:467–471. doi:10.1016/0002-9149(91)90780-o
- Maehara A, Mintz GS, Bui AB, et al. Incidence, morphology, angiographic findings, and outcomes of intramural hematomas after percutaneous coronary interventions: an intravascular ultrasound study. Circulation. 2002;105:2037–2042. doi:10.1161/01.cir.0000015503.04751.bd
- Landmesser U, Ali ZA, Maehara A, et al. Optical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial. Eur Heart J. 2024;45:4630–4643. doi:10.1093/eurheartj/ehae521
- Dunning DW, Kahn JK, Hawkins ET, O'Neill WW. Iatrogenic coronary artery dissections extending into and involving the aortic root. Catheter Cardiovasc Interv. 2000;51:387–393. doi:10.1002/1522-726x(200012)51:4<387::aid-ccd3>3.0.co;2-b
- Almeda FQ, Nathan S, Calvin JE, et al. Frequency of abrupt vessel closure and side branch occlusion after percutaneous coronary intervention in a 6.5-year period (1994 to 2000) at a single medical center. Am J Cardiol. 2002;89:1151–1155. doi:10.1016/s0002-9149(02)02295-6
- Hahn JY, Chun WJ, Kim JH, et al. Predictors and outcomes of side branch occlusion after main vessel stenting in coronary bifurcation lesions: results from the COBIS II Registry. J Am Coll Cardiol. 2013;62:1654–1659. doi:10.1016/j.jacc.2013.07.041
- Moussa ID, Klein LW, Shah B, et al. Consideration of a new definition of clinically relevant myocardial infarction after coronary revascularization: an expert consensus document from the Society for Cardiovascular Angiography and Interventions (SCAI). J Am Coll Cardiol. 2013;62:1563–1570. doi:10.1016/j.jacc.2013.08.720
- Khan M, Schmidt DH, Bajwa T, Shalev Y. Coronary air embolism: incidence, severity, and suggested approaches to treatment. Cathet Cardiovasc Diagn. 1995;36:313–318. doi:10.1002/ccd.1810360406
- Brilakis ES, Best PJ, Elesber AA, et al. Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv. 2005;66:333–340. doi:10.1002/ccd.20449
- Morita Y, Kashima Y, Yasuda Y, et al. Burr entrapment in a percutaneous coronary intervention during rotational atherectomy: an experience with 3195 cases. J Invasive Cardiol. 2023;35(10). doi:10.25270/jic/23.00174
- Flowers A, Evenhuis B, Gabanic B, et al. Stent thrombosis: a contemporary guide to definitions, risk factors, and management. Front Cardiovasc Med. 2025;12:1622235. doi:10.3389/fcvm.2025.1622235
- van Werkum JW, Heestermans AA, Zomer AC, et al. Predictors of coronary stent thrombosis: the Dutch Stent Thrombosis Registry. J Am Coll Cardiol. 2009;53:1399–1409. doi:10.1016/j.jacc.2008.12.055
- Almalla M, Schröder J, Hennings V, et al. Long-term outcome after angiographically proven coronary stent thrombosis. Am J Cardiol. 2013;111:1289–1294. doi:10.1016/j.amjcard.2013.01.268
- Mehran R, Baber U, Steg PG, et al. Cessation of dual antiplatelet treatment and cardiac events after percutaneous coronary intervention (PARIS): 2 year results from a prospective observational study. Lancet. 2013;382:1714–1722. doi:10.1016/S0140-6736(13)61720-1
- Buonamici P, Marcucci R, Migliorini A, et al. Impact of platelet reactivity after clopidogrel administration on drug-eluting stent thrombosis. J Am Coll Cardiol. 2007;49:2312–2317. doi:10.1016/j.jacc.2007.01.094
- Souteyrand G, Amabile N, Mangin L, et al. Mechanisms of stent thrombosis analysed by optical coherence tomography: insights from the national PESTO French registry. Eur Heart J. 2016;37:1208–1216. doi:10.1093/eurheartj/ehv711
- Joner M, Koppara T, Byrne RA, et al. Neoatherosclerosis in patients with coronary stent thrombosis: findings from optical coherence tomography imaging (a report of the PRESTIGE Consortium). JACC Cardiovasc Interv. 2018;11:1340–1350. doi:10.1016/j.jcin.2018.02.029
- Wykrzykowska JJ, Kraak RP, Hofma SH, et al. Bioresorbable scaffolds versus metallic stents in routine PCI (AIDA). N Engl J Med. 2017;376:2319–2328. doi:10.1056/NEJMoa1614954
- Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery (SIRIUS). N Engl J Med. 2003;349:1315–1323. doi:10.1056/NEJMoa035071
- Moussa ID, Mohananey D, Saucedo J, et al. Trends and outcomes of restenosis after coronary stent implantation in the United States. J Am Coll Cardiol. 2020;76:1521–1531. doi:10.1016/j.jacc.2020.08.002
- Mehran R, Dangas G, Abizaid AS, et al. Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation. 1999;100:1872–1878. doi:10.1161/01.cir.100.18.1872
- Nakazawa G, Otsuka F, Nakano M, et al. The pathology of neoatherosclerosis in human coronary implants: bare-metal and drug-eluting stents. J Am Coll Cardiol. 2011;57:1314–1322. doi:10.1016/j.jacc.2011.01.011
- Kirtane AJ, Shlofmitz R, Moses J, et al. Paclitaxel-coated balloon for the treatment of multilayer in-stent restenosis: AGENT IDE subgroup analysis. J Am Coll Cardiol. 2025;86:502–511. doi:10.1016/j.jacc.2025.05.062
- Chen Y, Li D, Liao Y, et al. Incidence of coronary drug-eluting stent fracture: a systematic review and meta-analysis. Front Cardiovasc Med. 2022;9:925912. doi:10.3389/fcvm.2022.925912
- Chakravarty T, White AJ, Buch M, et al. Meta-analysis of incidence, clinical characteristics and implications of stent fracture. Am J Cardiol. 2010;106:1075–1080. doi:10.1016/j.amjcard.2010.06.010
- Wańha W, Tomaniak M, Wańczura P, et al. Intravascular lithotripsy for the treatment of stent underexpansion: the multicenter IVL-DRAGON registry. J Clin Med. 2022;11:1779. doi:10.3390/jcm11071779
- Yeh RW, Shlofmitz R, Moses J, et al. Paclitaxel-coated balloon vs uncoated balloon for coronary in-stent restenosis: the AGENT IDE randomized clinical trial. JAMA. 2024;331:1015–1024. doi:10.1001/jama.2024.1361
- Giacoppo D, Alfonso F, Xu B, et al. Drug-coated balloon angioplasty versus drug-eluting stent implantation in patients with coronary stent restenosis (DAEDALUS). J Am Coll Cardiol. 2020;75:2664–2678. doi:10.1016/j.jacc.2020.04.006
- Benjo A, Cardoso RN, Collins T, et al. Vascular brachytherapy versus drug-eluting stents in the treatment of in-stent restenosis: a meta-analysis of long-term outcomes. Catheter Cardiovasc Interv. 2016;87:200–208. doi:10.1002/ccd.25998
- Bali AD, Lebrun S, Adi A, et al. Intravascular brachytherapy for the management of drug-eluting in-stent restenosis. J Invasive Cardiol. 2025;37(8). doi:10.25270/jic/24.00341
- Bay B, Goßling A, Remmel M, et al. Temporal trends and outcomes of acute ischaemic strokes in patients hospitalised for percutaneous coronary intervention. EuroIntervention. 2024;20:e1098–e1106. doi:10.4244/EIJ-D-24-00189
- US Food and Drug Administration. Premarket approval P170027: TherOx DownStream System (Zoll Circulation). Decision date April 2, 2019. accessdata.fda.gov
- McCartney PJ, Eteiba H, Maznyczka AM, et al. Effect of low-dose intracoronary alteplase during primary percutaneous coronary intervention on microvascular obstruction in patients with acute myocardial infarction: a randomized clinical trial. JAMA. 2019;321:56–68. doi:10.1001/jama.2018.19802