Library › Imaging › Structural heart imaging
Interventional imaging for structural heart procedures
Imaging before, during, and after transcatheter structural heart procedures in adults: CT planning, transesophageal and intracardiac echocardiographic guidance, recognition of complications, follow-up, and the training and safety of the interventional imager.
Gated contrast computed tomography (CT) plans most transcatheter valve and appendage procedures: it measures the annulus or landing zone, maps coronary arteries and access routes, and predicts obstruction. Transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE) then guides the device in real time, confirms the result, and detects complications. For mitral edge-to-edge repair, the 2026 American Society of Echocardiography (ASE) guideline sets a transseptal height of about 4.5–5.0 cm above the planned point of device deployment. It prefers a residual mean gradient below 5 mm Hg with a residual valve area of at least 2.0 cm².
The interventional imager and communication with the heart team
Transcatheter structural procedures are performed on a beating heart through catheters that the operator cannot see. Fluoroscopy shows wires, sheaths, and radiopaque frames, but it shows neither soft tissue nor blood flow. Any decision that depends on leaflets, the atrial septum, the appendage ostium, or flow therefore depends on the imager. The interventional echocardiographer is a procedural partner who anticipates the next decision and acquires the views that answer it. Examples are the site of septal puncture, coaxial alignment of the delivery system, capture of both leaflets, seal of an occluder, and stability of a device before release. An exhaustive diagnostic survey during a procedure prolongs the procedure, adds probe manipulation, and contributes little.
Communication follows a fixed structure. The imager names the view, the structure, and the finding in anatomic terms (anterior, posterior, medial, lateral, superior, inferior). Screen terms are avoided because screen left and right change with any rotation of a transducer or catheter. Measurements are stated with the conditions that alter them: heart rate for transmitral gradients, blood pressure for regurgitation, and inotrope or vasopressor use for outflow gradients. The imager also states whether the image is adequate for the decision being made (Little 2023). "Residual mitral regurgitation (MR) is moderate, arising lateral to the device, with a mean gradient of 4 mm Hg at 70 beats per minute" defines the lesion, its location, and the trade-off for a second device in one sentence. A finding that changes the procedure, such as a new pericardial effusion, is stated at once and repeated until the operator acknowledges it.
The 2026 ASE guideline for mitral edge-to-edge repair was written to standardize this exchange. It defines the imaging content that must be communicated at all procedural steps and the formats used to show it: two-dimensional, biplane, three-dimensional volume, and three-dimensional multiplanar reconstruction (Little 2026). Most of its recommendations rest on writing-group consensus and observational data, because randomized evidence for individual procedural steps does not exist.
Before the procedure the heart team integrates the clinical indication with three imaging questions: whether the lesion is what the referral says it is, whether the anatomy suits the planned device, and which complications the anatomy predicts. After the procedure the imager hands off findings that change care, records baseline measurements for later comparison, and plans surveillance. Indications for the individual procedures, trial outcomes, and antithrombotic therapy belong to the disease pages: aortic stenosis, mitral regurgitation, atrial fibrillation, atrial septal defect and patent foramen ovale, and prosthetic heart valves.
Choice of imaging modality by procedure
A modality is chosen for what it shows of the target and the likely complications. TEE gives high spatial and temporal resolution of left-sided structures and three-dimensional en face views of the mitral valve and appendage. It usually requires general anesthesia or deep sedation when used for long procedures. ICE is placed and steered by the operator from the femoral vein, permits conscious sedation, and replaces or supplements TEE for septal, appendage, electrophysiology, and some tricuspid procedures. Transthoracic echocardiography (TTE) monitors transfemoral aortic valve replacement under sedation and is the standard follow-up test. Gated CT supplies annular, coronary, access, and outflow geometry before the procedure and characterizes leaflet thrombosis and device position afterward.
| Procedure | Planning | Intraprocedural guidance | Principal imaging end points | Follow-up imaging |
|---|---|---|---|---|
| Transcatheter aortic valve replacement (TAVR) | TTE for severity; gated CT for annulus, root, coronary heights, access | Fluoroscopy with TTE or TEE | Valve position and depth, paravalvular regurgitation, gradient, effusion, wall motion, mitral apparatus | TTE baseline and annually; CT for suspected leaflet thrombosis |
| Mitral edge-to-edge repair | Screening TEE with three-dimensional imaging | Two- and three-dimensional TEE | Transseptal height, alignment, leaflet insertion, residual MR, gradient, orifice area, iatrogenic ASD | TTE |
| Transcatheter mitral replacement, valve-in-valve, valve-in-ring | Gated CT for annulus and predicted neo-LVOT; TEE | Two- and three-dimensional TEE | Outflow and transmitral gradients, paravalvular regurgitation, stability | TTE; CT for leaflet thrombosis |
| Tricuspid repair or replacement | TTE and TEE for mechanism; CT for annulus, right coronary artery, leads | TEE, often with ICE or TTE | Leaflet capture, residual TR, diastolic gradient, lead position | TTE |
| Left atrial appendage occlusion (LAAO) | TEE or CT | TEE or ICE | Thrombus exclusion, landing zone, compression, seal, effusion | TEE or CT at 45–90 days |
| ASD or PFO closure | TTE, TEE, or ICE | TEE or ICE | Rims, disc position, residual shunt, impingement | TTE with contrast |
| Paravalvular leak closure | Three-dimensional TEE; CT for complex defects | Two- and three-dimensional TEE | Defect map, wire crossing, residual leak, leaflet or occluder interference | TTE |
| Balloon mitral valvuloplasty | TTE and TEE (Wilkins features, appendage thrombus) | TEE or ICE with fluoroscopy | Commissural split, valve area, gradient, new MR | TTE |
| Alcohol septal ablation | TTE | TTE with myocardial contrast | Perforator territory, gradient, systolic anterior motion | TTE |
Imaging by structural procedure, after the 2023 ASE competency recommendations, the 2022 ASE screening standards, the 2026 ASE guideline for mitral transcatheter edge-to-edge repair (M-TEER), and the 2025 Society for Cardiovascular Angiography and Interventions (SCAI) and Heart Rhythm Society (HRS) LAAO guideline. MR, mitral regurgitation; TR, tricuspid regurgitation; ASD, atrial septal defect; PFO, patent foramen ovale; LVOT, left ventricular outflow tract.
The general features of TEE (views, contraindications, sedation, and complication rates) are covered on the transesophageal echocardiography page, and the physics of matrix arrays and intracardiac catheters on the echocardiography physics page.
Screening transesophageal echocardiography before structural intervention
A screening TEE before a structural procedure differs from a diagnostic study. The 2022 ASE standards define it as procedure specific. It establishes the mechanism and severity of the lesion, measures the dimensions that select the device, and identifies adjacent structures at risk. It also assesses the access path (the atrial septum for transseptal procedures) and excludes contraindications such as left atrial or appendage thrombus, endocarditis, or anatomy that no available device can treat (Hahn 2022). The report answers the heart team's question for a named procedure.
For mitral edge-to-edge repair, the screening study maps the diseased scallops and measures leaflet length at the intended grasping site, flail gap and width, and the valve area by three-dimensional planimetry. In secondary MR it also measures coaptation depth and length. The baseline mean gradient is recorded at a stated heart rate. The study also describes calcium and clefts in the grasping zone. For appendage occlusion it measures the ostium, landing zone, and depth in several planes and describes lobes and thrombus. For tricuspid procedures it defines leaflet number and morphology, coaptation gap, annular size, the relation of pacemaker or defibrillator leads to the leaflets, and right ventricular function. For paravalvular leaks it locates all defects on a clock face. For septal closure it measures the defect and all rims. In all cases the screening study records the window quality, because a valve that is poorly seen from the esophagus during screening will be poorly seen during the procedure.
Transesophageal echocardiography during procedures: anesthesia, safety, and esophageal injury
Intraprocedural TEE differs from diagnostic TEE in duration and probe manipulation. A mitral or tricuspid repair can keep the probe in the esophagus for hours with repeated flexion and transgastric positioning, often in an anticoagulated patient. In a prospective study of 50 patients who underwent esophagogastroduodenoscopy before and immediately after TEE-guided mitral, tricuspid, appendage, and paravalvular leak procedures, 86% had a new esophageal or gastric injury, and 40% had complex lesions (intramural hematoma or mucosal laceration). Imaging time raised the odds of a complex lesion (odds ratio 1.27 per 10-minute increment), as did poor or suboptimal image quality (odds ratio 4.93). Complex lesions were associated with more postprocedural dysphagia or odynophagia (Freitas-Ferraz 2020). These findings support minimizing probe manipulation, relaxing flexion when imaging is not needed, and keeping the probe tip in neutral between steps. The rates of complications in diagnostic and intraoperative series, the gastrointestinal contraindications, and probe care are on the transesophageal echocardiography page.
General anesthesia for TEE-guided procedures secures the airway, eliminates patient movement, and allows breath-holds during three-dimensional acquisition. It also lowers afterload and preload, which makes MR appear smaller, increases dynamic outflow obstruction, and alters gradients. Residual regurgitation after a repair is therefore graded with blood pressure restored toward awake values when possible, the approach also used for intraoperative TEE in cardiac surgery (Nicoara 2020).
TEE-guided TAVR compared with sedation and TTE. Early TAVR programs used general anesthesia with TEE. Many transfemoral procedures now use local anesthesia with conscious sedation, fluoroscopy, and TTE. In the randomized SOLVE-TAVI trial (447 patients, 2 × 2 factorial design), conscious sedation was equivalent to general anesthesia for the 30-day composite of death, stroke, myocardial infarction, infection requiring antibiotics, and acute kidney injury (27.2% with conscious sedation and 26.4% with general anesthesia). Vasopressors or inotropes were used far less often with conscious sedation (62.8%) than with general anesthesia (97.3%) (Thiele 2020). TEE remains useful when transthoracic windows are poor, when valve position or paravalvular regurgitation is uncertain, in valve-in-valve and bicuspid cases at some centers, and whenever a complication is suspected. TTE under sedation is limited by the supine position and the sterile field. The parasternal and apical windows are often partial, so the transthoracic imager works quickly from off-axis views.
Three-dimensional TEE, biplane imaging, and multiplanar reconstruction
Three-dimensional TEE changed structural guidance by showing the mitral valve, appendage ostium, and atrial septum en face, as a surgeon sees them, and by showing catheters in relation to their target in one volume. Three formats are used during procedures:
- Biplane (simultaneous multiplane) imaging displays two orthogonal two-dimensional planes at full two-dimensional frame rate. During mitral repair, the intercommissural view and the orthogonal long-axis (left ventricular outflow tract) view together show medial–lateral and anterior–posterior position of the device without moving the probe.
- Live three-dimensional and three-dimensional zoom volumes display the en face "surgical view" of the mitral valve, with the aortic valve at 12 o'clock and the appendage at 9 o'clock. They also show the device arms relative to the line of coaptation and the tissue bridge after grasping. A zoom box drawn closely around the target keeps volume rate and line density high; an oversized box lowers both.
- Three-dimensional multiplanar reconstruction (MPR) reslices a volume along any three orthogonal planes. It aligns a measurement plane exactly with the leaflet tips for planimetry of a double orifice, measures leaflet length at the true grasping site, and sizes an iatrogenic atrial septal defect. The 2026 ASE guideline recommends three-dimensional modalities for transseptal puncture and treats MPR as the reference method for orifice area after edge-to-edge repair (Little 2026).
Multibeat full-volume acquisition stitches narrow subvolumes from several gated beats into a wide field. Arrhythmia, respiration, and probe or catheter motion produce stitching artifacts, so single-beat acquisition is used during atrial fibrillation and during active device manipulation. Three-dimensional color Doppler lowers the volume rate further and is acquired in a narrow sector. The principles of volume rate and stitching are covered on the echocardiography physics page.
Intracardiac echocardiography: catheters, views, and limitations
ICE places a miniaturized transducer on the tip of a steerable catheter. The catheter is usually inserted through a femoral venous sheath of 8 to 10 French and positioned in the right atrium, the right ventricle, or, after septal crossing, the left atrium (Leuzzi 2026). It is manipulated by the interventional operator, so a second imaging physician and general anesthesia are not required. ICE is standard in many electrophysiology procedures and is increasingly used for septal closure, appendage occlusion, tricuspid repair, and transseptal access for mitral procedures. A 2025 SCAI position statement describes ICE as giving real-time, high-resolution images without general anesthesia. It proposes standardized protocols and views for the individual procedures and calls for comparative studies and payment models that reflect the work involved (Eleid 2025).
| Catheter type | Image format | Principal uses | Limitations |
|---|---|---|---|
| Phased-array two-dimensional | Steerable sector, typically 5–10 MHz, with color, pulsed-wave, and continuous-wave Doppler | Transseptal puncture, septal closure, appendage occlusion, electrophysiology, effusion surveillance | Single plane; far-field resolution limited; orientation depends on catheter position |
| Rotational (mechanical) | 360° radial image perpendicular to the catheter, high frequency | Historically electrophysiology and septal imaging | Limited depth and steering; no Doppler; largely superseded |
| Three-dimensional and four-dimensional (matrix array) | Live volumes, biplane, and multiplanar reconstruction from the catheter tip | Appendage occlusion, tricuspid and mitral repair, septal closure | Narrower volumes and lower resolution than three-dimensional TEE; larger catheters; cost |
Intracardiac echocardiography catheter types. Commercial phased-array systems include AcuNav, ViewFlex, SoundStar, and VeriSight Pro; volumetric catheters are available from several manufacturers.
Views. ICE planes depend on catheter position, rotation, and tip deflection, so orientation comes from anatomic landmarks. With a phased-array catheter in the mid right atrium in neutral position, the "home view" shows the tricuspid valve, right ventricle, and right ventricular outflow tract. Clockwise rotation brings the aortic valve, then the interatrial septum with the left atrium and mitral valve, then the left atrial appendage and the left pulmonary veins into view; the sequence varies with system and anatomy. Posterior deflection with clockwise rotation shows the septum in a long-axis plane for transseptal puncture. Advancing the catheter toward the tricuspid annulus or into the right ventricle shows the left ventricle, pericardium, and tricuspid leaflets. After transseptal crossing, an ICE catheter placed in the left atrium gives close, high-quality images of the appendage ostium, landing zone, and device. At many centers this provides appendage imaging comparable with TEE.
ICE compared with TEE. ICE avoids esophageal intubation, the airway risks of prolonged sedation, and the esophageal injury described above, and it frees the imaging physician for other cases. It allows conscious sedation in patients who prefer to avoid general anesthesia or who have esophageal disease. Its limitations are a narrower field of view, lower far-field resolution, a second venous access with its vascular risks, single-use catheter cost, and a learning curve in which orientation errors are common. The catheter tip can perforate the atrium if it is advanced without being seen, so the tip is kept in view during manipulation.
For appendage occlusion, comparative data are observational. In the prospective ICE LAA study, 100 patients received a Watchman FLX under ICE guidance from the left atrium after planning CT or TEE within 7 days. Technical success was 100%, no patient required conversion to TEE, and no peridevice leak larger than 5 mm was present on 45-day TEE (Nielsen-Kudsk 2023). In the US SURPASS registry, ICE guided 5.7% of 39,759 attempted procedures; complete occlusion was high with both modalities, but ICE was associated with more pericardial effusions requiring intervention (Ferro 2023). A 2026 meta-analysis of 27 observational studies found comparable procedural success, shorter procedure time with ICE in adjusted analyses (mean difference about 21 minutes), and more in-hospital effusions requiring intervention with ICE (adjusted odds ratio 1.74) (Yaser 2026). The 2025 SCAI/HRS guideline suggests either ICE or TEE during appendage occlusion (conditional recommendation, low certainty), noting that patients who prefer to avoid general anesthesia and TEE would reasonably choose ICE (Goldsweig 2025). An ICE-guided implant depends on prior TEE or CT, because ICE from the right atrium cannot reliably exclude appendage thrombus.
Echocardiography–fluoroscopy fusion, CT overlay, and computational modeling
Fusion imaging registers live TEE or ICE images to the fluoroscopic projection, so that the operator sees the echocardiographic image, or markers placed on it, in the same orientation as the fluoroscopic catheter. Commercial systems track the TEE probe position on fluoroscopy and overlay the echo sector or user-placed markers on the live fluoroscopic image. Examples of markers are the transseptal target, the center of a mitral orifice, and the edges of a paravalvular defect. Fusion reduces the mental translation between imaging coordinate systems and has been used for transseptal puncture, edge-to-edge repair, valve-in-valve implantation, and paravalvular leak closure; its benefit on outcomes has not been tested in randomized trials. CT-derived three-dimensional models can also be overlaid on fluoroscopy to show the annular plane, coronary ostia, or appendage contour. Registration error and changes in loading and respiration between scan and procedure mean the overlay is verified against live imaging.
Physical models (three-dimensional printing) and computational simulation predict how a device will interact with patient-specific anatomy: neo-left ventricular outflow tract area after mitral replacement, frame-to-root interaction and coronary risk after aortic valve-in-valve, and appendage device fit. Their predictions depend on segmentation, assumed device geometry, implant depth, and tissue deformation, so a simulation is an estimate of future anatomy and not a guarantee (Faza 2024). Artificial intelligence tools for automated annular segmentation, view recognition, and three-dimensional reconstruction are in early clinical use.
Transseptal puncture: site selection by procedure
Transseptal access is the first step of mitral repair and replacement, appendage occlusion, many paravalvular leak closures, and left-sided ablation. Devices travel different paths to their targets, so the puncture site is chosen for the procedure. The needle raises a "tent" in the fossa ovalis before it crosses, and imaging locates the tent in three dimensions. The 2026 ASE guideline requires confirmation in three planes about 60° apart (Little 2026). The bicaval view shows superior–inferior position, the aortic valve short-axis view shows anterior–posterior position, and the four-chamber view (about 0°–15°) shows height above the mitral coaptation plane. A tent directed toward the aortic root risks aortic puncture, and one against the posterior atrial wall risks exit from the heart. A thick, lipomatous, or aneurysmal septum, a previous closure device or surgical patch, and a very small or very large left atrium alter the approach. After crossing, a new pericardial effusion is excluded.
| Procedure | Preferred puncture site | Reason |
|---|---|---|
| Mitral edge-to-edge repair | Posterior, mid to superior; about 4.5–5.0 cm above the planned point of device deployment | Room to steer the guide down to the coaptation line coaxially; a medial target usually needs at least 4.5 cm, and a lateral target tolerates less height |
| Transcatheter mitral replacement and valve-in-valve | Posterior and inferior to mid, with height for the delivery system | Coaxial delivery of a large valve to the mitral annulus |
| Left atrial appendage occlusion | Inferior and posterior | Alignment of the delivery sheath with the anterosuperiorly directed appendage axis |
| PFO closure | Through the PFO tunnel (no puncture) | The device is placed across the tunnel; puncture is used only when the tunnel is long or cannot be crossed |
| Pulmonary vein isolation | Inferior and posterior or mid | Reach to all four vein ostia |
Transseptal puncture sites by procedure, after the 2026 ASE M-TEER guideline and the 2023 ASE competency recommendations. Heights are measured in the four-chamber view and confirmed on a two-dimensional image.
The required height for mitral repair depends on the mechanism and the target. In secondary MR with tethered leaflets, the device is deployed below the annulus; in primary MR with prolapse, it is deployed at or slightly above the annular plane. Height is gained by clockwise rotation of the transseptal catheter toward the mid and superior fossa, while an anterior, "aorta-hugging" trajectory is avoided (Little 2026). When height is measured from the coaptation point instead of the annulus, the guideline gives an ideal distance of 4.0 to 4.5 cm, at the higher end for medial lesions (Little 2026). Complications of transseptal puncture include tamponade, aortic puncture, and embolism. In a multicenter survey of 5,520 transseptal catheterizations for arrhythmia ablation, complications occurred in 0.74% to 0.79% (De Ponti 2006). Tamponade occurred in 5 of 393 transseptal procedures in a single-operator series, all during atrial fibrillation ablation (Katritsis 2013), and inadvertent aortic puncture in 0.05% of 4,305 punctures in a single-center series (Wasmer 2017).
CT planning for TAVR: the annular plane, cardiac phase, and sizing
Contrast-enhanced, ECG-synchronized CT of the aortic root with a run-off acquisition of the aorta, iliac, and femoral arteries is the standard planning study for TAVR (Blanke 2019). Small measurement errors change device selection and procedural risk. The sequence is fixed: the annular plane is constructed first, and all root and coronary measurements are made relative to it. Valve calcium scoring, coronary CT angiography before TAVR, and the clinical components of the TAVR report are on the aortic stenosis page.
The annular plane. The aortic "annulus" is a virtual ring through the lowest hinge points of the three cusps. It is constructed by double-oblique multiplanar reconstruction through the three basal hinge points, orthogonal to the root centerline. An annulus traced on a scanner axial image is an oblique section through an ellipse and overestimates area. A noncontrast calcium scan shows calcium well but cannot define the hinge points, so formal sizing uses the contrast-enhanced gated dataset.
Cardiac phase. The annulus changes size and shape through the cardiac cycle and is usually largest in early to mid systole. The Society of Cardiovascular Computed Tomography (SCCT) consensus prefers systolic measurements for device sizing. When multiple phases are reconstructed, the phase with the largest annulus of adequate image quality is measured, and a fixed diastolic phase is not adopted without comparison (Blanke 2019).
Area and perimeter. Area and perimeter are the primary sizing measurements, preferred over isolated diameters (Blanke 2019). Minimum and maximum diameters describe the shape. An oval annulus of 20 × 28 mm has a mean diameter of 24 mm, but its area and perimeter may select a different valve size than that mean diameter would. Area-derived and perimeter-derived diameters assume a circle; the perimeter traced around a jagged contour is inflated unless the contour is smoothed. Sizing follows the current manufacturer's device-specific tables, which differ between devices and generations, and no universal annular cutoff exists.
Valve morphology and calcium. The report describes the number of cusps, fusion pattern, raphe, commissural orientation, and the amount and location of leaflet, annular, and outflow tract calcium. In bicuspid valves, an elliptical annulus, a calcified raphe, and asymmetric sinuses change anchoring and frame expansion, and the supra-annular level (intercommissural distance) is often measured as well. Calcium is reported by location, extent, protrusion, and asymmetry, because location predicts the complication. Bulky subannular or outflow tract calcium predicts annular rupture, paravalvular regurgitation, and, near the membranous septum, conduction injury. A total calcium score without spatial distribution omits what the operator needs.
Membranous septum. The membranous septum lies below the commissure between the right and noncoronary cusps, above the conduction axis. A short membranous septum measured on coronal CT, and an implant depth that approaches or exceeds its length, are associated with atrioventricular block after TAVR (Hamdan 2015). Membranous septal length is therefore part of the planning report and informs target implant depth.
| Step | Measurement | Source of error |
|---|---|---|
| 1 | Construct the plane through the three basal hinge points | Scanner axial image; oblique section overestimates area |
| 2 | Review reconstructed phases and choose the largest adequate annulus, usually systolic | Fixed diastolic phase undersizes |
| 3 | Trace the blood-pool–tissue interface and report area and perimeter | Jagged contour inflates perimeter; calcium included or excluded inconsistently |
| 4 | Report minimum and maximum diameters as shape descriptors | Sizing from one diameter |
| 5 | Measure coronary heights perpendicular to the annular plane and sinus and sinotubular junction dimensions | Measurement along the curved wall |
| 6 | Describe valve morphology, calcium location, and membranous septal length | Total calcium score only |
| 7 | Assess aorta, iliac, and femoral arteries; derive coplanar fluoroscopic angles | Single iliac diameter without location or calcium |
| 8 | Apply the current device-specific sizing table | Universal cutoffs; mixing area-based and perimeter-based oversizing |
A measurement sequence for TAVR planning CT, after the 2019 SCCT expert consensus.
TAVR annulus and oversizing calculator
Oversizing is the nominal measurement of the transcatheter valve divided by the matching annular measurement, minus one, expressed as a percentage. Area oversizing is compared with area-based targets and perimeter oversizing with perimeter-based targets; the two differ for the same device and are never mixed. In a case–control study of aortic root rupture during balloon-expandable TAVR, moderate or severe outflow tract or subannular calcification (odds ratio 10.92) and annular area oversizing of 20% or more (odds ratio 8.38) were independently associated with rupture (Barbanti 2013).
Area-derived diameter = 2 × √(area ÷ π); perimeter-derived diameter = perimeter ÷ π; mean diameter = (minimum + maximum) ÷ 2; eccentricity index = 1 − minimum ÷ maximum diameter. Oversizing (%) = (valve nominal measurement ÷ annular measurement − 1) × 100, using the same measurement type. The default values describe an oval annulus (area 430 mm², perimeter 75 mm) and a valve (nominal area 531 mm², nominal perimeter 81.7 mm). These give area oversizing of 23.5% and perimeter oversizing of 8.9%. Nominal device dimensions and sizing ranges come from the current instructions for use.
Root anatomy, coronary obstruction risk, and valve-in-valve planning
Coronary obstruction occurs when the transcatheter valve displaces a native or surgical leaflet outward against a coronary ostium or seals the sinus at the sinotubular junction. In a multicenter registry of 6,688 TAVR procedures, symptomatic coronary obstruction occurred in 0.66%, mostly of the left coronary artery (88.6%), and was more frequent in women, with balloon-expandable valves, and in valve-in-valve procedures. Patients with obstruction had a lower left coronary ostium (mean 10.6 compared with 13.4 mm) and a smaller mean sinus of Valsalva diameter (28.1 compared with 31.9 mm) (Ribeiro 2013). Pre-TAVR CT reports coronary height, mean sinus diameter, and sinotubular junction height and diameter (Blanke 2019).
Coronary height is measured separately for the left and right coronary ostia, along a line perpendicular to the annular plane, from the plane to the lower edge of the ostium. Measurement along the curved aortic wall or from an oblique plane gives a falsely high value. Low coronary height (below 10 mm) and a mean sinus diameter below 30 mm are risk markers, and TAVR remains an option when they are present (Shatila 2017); sinus width, leaflet length and bulk, and the valve design modify the risk. A left main height of 10 mm with wide sinuses and a short leaflet differs from the same height with narrow sinuses and a long, bulky leaflet whose tip lies above the ostium.
Valve-in-valve. Planning begins with identification of the surgical valve: model, labeled size, true internal diameter, frame height, leaflet mounting (inside or outside the stent posts), and radiopacity. The labeled size of a surgical valve is not its internal diameter. In stented surgical valves whose posts extend above the coronary ostia, the intended transcatheter valve is simulated as a cylinder within the surgical frame. The virtual transcatheter valve-to-coronary distance (VTC) is measured from the simulated frame to the ostium, and a VTC below 4 mm identifies high risk. Stentless valves and root replacements have no rigid frame and are assessed with native-style coronary height and sinus dimensions. A narrow, low sinotubular junction can pin the displaced leaflets against the aortic wall and occlude the whole sinus (sinus sequestration), and its diameter and height are reported separately from the sinus diameter (Lederman 2019). In high-risk anatomy, the leaflet in front of the threatened ostium can be lacerated with an electrified wire before implantation (BASILICA, bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction). Alternatively, a coronary stent can be positioned to protect the ostium. Outcomes of valve-in-valve treatment are on the prosthetic heart valves page.
| Feature | Higher-risk finding | Interpretation |
|---|---|---|
| Coronary height (native valve) | Below 10 mm | Risk marker integrated with sinus width and leaflet geometry |
| Mean sinus of Valsalva diameter | Below 30 mm | Risk marker integrated with coronary height |
| Leaflet length and bulk | Leaflet tip above a low ostium; bulky calcified leaflet | Mechanism of direct ostial obstruction |
| Sinotubular junction | Narrow, low, or calcified | Sinus sequestration, especially in valve-in-valve |
| Virtual transcatheter valve-to-coronary distance (VTC) | Below 4 mm | High risk in stented surgical valve-in-valve with posts above the ostia |
| Surgical valve design | Externally mounted leaflets; stentless valve | Higher obstruction rates than internally mounted designs |
Anatomic features associated with coronary obstruction during TAVR, after the 2019 SCCT consensus, the multicenter coronary obstruction registry, and the 2019 review of CT prediction and leaflet laceration, with the coronary height cutoff from Shatila 2017. Criteria by valve type are given under coronary obstruction risk from planning CT.
Future coronary access is also part of planning in younger patients. A tall frame with a high skirt and commissures misaligned with the coronary ostia can make later coronary catheterization or a second transcatheter valve difficult. Commissural alignment techniques and CT assessment of the projected neoskirt plane reduce this difficulty.
Access route assessment and fluoroscopic projections
CT assesses the aorta and the iliac and common femoral arteries for minimal luminal diameter, calcification (circumferential calcium limits vessel expansion), tortuosity, aneurysm, dissection, and the level of the femoral bifurcation relative to the femoral head. The minimal vessel diameter required depends on the outer diameter of the current sheath and delivery system. No single cutoff applies, and a common femoral artery of 5.5 mm may be suitable for one system and not for another. A single iliac diameter reported without location or calcium distribution is insufficient for planning. When transfemoral access is unsuitable, CT evaluates subclavian or axillary, transcarotid, transcaval (the relationship of the inferior vena cava to a calcium-free window in the abdominal aorta), and transapical or transaortic routes. Pulmonary findings, aortic atheroma, and incidental masses on the run-off acquisition are reported.
CT also predicts fluoroscopic projections. The annular plane defines an S-shaped curve of coplanar angles. A coplanar view lines up the three cusp nadirs. A cusp-overlap view (right and left cusps overlapping, noncoronary cusp isolated) elongates the outflow tract and reduces parallax during deployment of self-expanding valves. The angles are reported as right or left anterior oblique and cranial or caudal values. They guide the procedure and do not measure anatomy.
Intraprocedural imaging during TAVR: position, paravalvular regurgitation, and gradients
Before deployment, echocardiography confirms severity when grading was discordant, records left ventricular function, septal hypertrophy, mitral regurgitation, and the baseline pericardium, and documents any aortic regurgitation for later comparison. Gated CT is the current sizing method and has replaced two-dimensional TEE annular diameter. During deployment, fluoroscopy and aortography are primary. TEE, when used, shows the frame relative to the annulus and the anterior mitral leaflet in the long-axis view.
After deployment, imaging confirms valve position, leaflet motion, and the absence of new effusion or wall motion abnormality, and it grades regurgitation. Implant depth is the distance from the native annulus to the ventricular end of the frame on the noncoronary and left coronary sides, compared with the device-specific target; a low valve presses on the conduction system and the anterior mitral leaflet, and a high valve risks embolization and paravalvular regurgitation. Paravalvular regurgitation after TAVR is usually multiple and eccentric. Jets are located in short axis at and just below the frame and are confirmed as paravalvular by flow convergence outside the frame. Grading integrates the combined circumferential extent with vena contracta width, diastolic flow reversal in the descending aorta, and left ventricular findings (Zoghbi 2019; Zoghbi 2024). A combined circumferential extent below 10% is consistent with mild, 10% to 29% with moderate, and 30% or more with severe regurgitation. The full grading table and the outcome data are on the prosthetic heart valves page. Moderate or severe regurgitation at this stage can be treated during the same procedure by balloon postdilation, a second valve, or a plug. It is reported at once with its location and mechanism (underexpansion next to calcium, malposition, or undersizing).
The postprocedural gradient and effective orifice area are recorded as the baseline for surveillance. Gradients measured during the procedure are affected by anesthesia, pacing, and high-output states, so the early TTE at stable loading becomes the formal baseline. The Valve Academic Research Consortium 3 (VARC-3) document defines valve hemodynamic performance, paravalvular regurgitation, and bioprosthetic valve dysfunction for clinical research (Généreux 2021).
Complications of TAVR recognized by imaging
Sudden hypotension during or after deployment is investigated systematically, because the causes have distinct imaging signatures and different treatments.
| Complication | Imaging findings | Predisposing anatomy |
|---|---|---|
| Annular or root rupture | New effusion, hematoma around the root, contrast extravasation; occasionally a new jet into another chamber | Bulky subannular or outflow tract calcium, area oversizing ≥20%, balloon postdilation |
| Ventricular perforation by the stiff wire | New effusion with chamber collapse; normal root | Small, hypertrophied ventricle; wire position at the apex |
| Coronary obstruction | New regional wall motion abnormality, usually anterior and lateral; loss of coronary flow on color Doppler | Low coronary height, narrow sinus, long bulky leaflet, valve-in-valve |
| Severe aortic regurgitation | Large paravalvular or central jet; holodiastolic flow reversal; rising ventricular diastolic pressure | Undersizing, malposition, asymmetric calcium, stuck leaflet |
| Aortic dissection | Intimal flap in the ascending aorta or arch | Atheroma, root dilation, aggressive balloon dilation |
| Valve embolization or migration | Frame displaced into the aorta or ventricle | Undersizing, high or low implantation, minimal calcium |
| Mitral apparatus injury | New MR from anterior leaflet perforation or chordal entrapment by the wire | Low implantation, wire course through chordae |
| Dynamic outflow obstruction | Late-peaking outflow velocity, systolic anterior motion after relief of afterload | Septal hypertrophy, small cavity, hypovolemia |
Causes of hemodynamic deterioration during TAVR and their imaging findings.
A new effusion with right ventricular diastolic collapse identifies tamponade, and imaging then guides pericardiocentesis. Mild paravalvular regurgitation does not explain hypotension, and unchanged regional wall motion argues against coronary obstruction. The management of tamponade and the technique of echocardiographically guided pericardiocentesis are on the pericardial effusion and tamponade page. Conduction disturbance is among the most frequent complications of TAVR and is detected by ECG monitoring, although CT anatomy (membranous septal length and calcium below the noncoronary–right commissure) predicts it.
Screening for mitral edge-to-edge repair: feasibility by anatomy
The 2026 ASE guideline grades the anatomy for M-TEER from optimal through complex and very complex to likely prohibitive, and stresses that the minimum leaflet length is device specific (Little 2026). Anatomic selection for the procedure, its trial evidence, and its indications are on the mitral regurgitation page; the imaging thresholds that the imager reports are summarized here.
| Feature | Optimal | Complex | Very complex | Likely prohibitive |
|---|---|---|---|---|
| Location of pathology | A2/P2 | A1/P1 or A3/P3 | Multiple scallops | Cleft or perforation; endocarditis |
| Mitral valve area (three-dimensional planimetry) | >4.0 cm² | 3.5–4.0 cm² | 3.0–3.5 cm² | <3.0 cm² |
| Baseline mean gradient (60–80 beats/min) | <5 mm Hg | — | — | >5 mm Hg unless attributable to MR flow |
| Posterior leaflet length | >10 mm | 8–10 mm | 6–8 mm | <6 mm |
| Minimum leaflet length by device | ≥6 mm for MitraClip NT/NTW; ≥9 mm for MitraClip XT/XTW; ≥8 mm for PASCAL | |||
| Flail (primary MR) | Width <15 mm, gap <10 mm | Width >15 mm, gap >10 mm | — | — |
| Calcification | None | Annular calcification without leaflet involvement | Leaflet calcification outside the grasping zone | Severe leaflet calcification in the grasping zone |
| Subvalvular apparatus and prior intervention | Chord-free grasping zone | Minimal chords in the grasping zone | Annuloplasty ring; previous single-leaflet device attachment; hypertrophic cardiomyopathy | Severely calcified subvalvular apparatus, including chords |
| Leaflet mobility and thickness | Normal | Normal or excessive leaflet mobility and thickness | Excessive or slightly restricted mobility; Barlow disease; increased thickness | Rheumatic thickening and restriction |
Echocardiographic feasibility of mitral edge-to-edge repair, after Figures 2 and 3 of the 2026 ASE M-TEER guideline. Complex and very complex anatomy is considered at experienced centers; the guideline text adds that a valve area below 3.5 cm² is often a contraindication. A raised gradient in severe MR may reflect high transmitral flow and is interpreted with the valve area.
Leaflet length is measured at the intended site of device implantation, in a long-axis view, from a bicommissural biplane view, or by three-dimensional MPR aligned to the planned device orientation. The posterior leaflet is radially shorter than the anterior, so its length is usually the limiting measurement. A baseline gradient is reported with the heart rate, because the same valve gives a higher gradient at a faster rate.
Intraprocedural imaging for mitral edge-to-edge repair
The procedure is a sequence of imaging-defined steps with end points that the imager confirms before the operator proceeds (Little 2026).
| Step | Views and formats | Imaging end point |
|---|---|---|
| Baseline | Two- and three-dimensional TEE; Doppler | Mechanism and location of MR, valve area, mean gradient with heart rate, pulmonary venous flow, left atrial and appendage thrombus excluded, baseline effusion |
| Transseptal puncture | Bicaval, aortic short-axis, and four-chamber views about 60° apart; biplane or three-dimensional | Posterior, mid to superior site within the fossa ovalis; height about 4.5–5.0 cm above the deployment point; no effusion after crossing |
| Guide and delivery system in the left atrium | Biplane or three-dimensional; tracking toward the annulus | Catheter tip away from the left atrial wall and appendage; coaxial approach to the valve |
| Device steering and orientation | Intercommissural view (about 60°) for medial–lateral position; long-axis view (about 120°) for anterior–posterior position; three-dimensional en face or MPR | Device centered over the origin of the jet; arms perpendicular to the line of coaptation |
| Entry into the ventricle | Long-axis and intercommissural views | Arms open below the leaflets, free of chordae; orientation preserved |
| Leaflet grasp | Long-axis view, biplane, partial closure, transgastric or three-dimensional en face | Leaflets drape over the arms; residual leaflet immobile at the grasp; leaflet shortened at the device; tissue bridge on en face imaging |
| Before release | Color Doppler, continuous-wave Doppler, pulmonary venous Doppler, three-dimensional MPR planimetry | Residual MR, mean gradient with heart rate, orifice area, stroke volume, device stability |
| After release and septal crossing | Color Doppler of the septum; pericardial survey | Iatrogenic atrial septal defect size and shunt direction; no new effusion |
Imaging steps during mitral edge-to-edge repair, after the 2026 ASE M-TEER guideline.
One two-dimensional plane can hide device rotation in the other, so medial–lateral and anterior–posterior position are confirmed together. The three-dimensional en face view confirms that the arms cross the coaptation line perpendicularly for most lesions. The open device is withdrawn from the ventricle toward the leaflets without entangling chordae; a device that rotates on withdrawal has usually caught a chord.
Leaflet insertion. The 2026 ASE guideline lists four signs of adequate insertion: draping of the leaflets over the device arms or paddles, immobility of the residual leaflet tissue at the grasp, shortening of visible leaflet tissue at the device compared with the tissue immediately medial and lateral to it, and a tissue bridge on three-dimensional or transgastric en face imaging. The base of the tissue bridge on both leaflets should be about twice as wide as the central device; a narrow base suggests tenuous insertion and prompts biplane interrogation of both leaflets. A fall in color jet area does not prove capture, because a device attached to one leaflet can coexist with a smaller jet in one view. Single-leaflet device attachment and leaflet tear are recognized by a freely moving leaflet beside the device and new or recurrent regurgitation, and they limit later options, including transcatheter replacement.
Residual MR, gradient, and orifice area after edge-to-edge repair
Grading residual MR after edge-to-edge repair is difficult. The device creates a double (or multiple) orifice, jets are eccentric and arise beside the device, and the device casts acoustic shadows. Jet area, a single vena contracta width, and the proximal isovelocity surface area method are therefore unreliable, and a multiparametric approach is recommended (Zoghbi 2019; Little 2026). The principal parameters are:
- Color Doppler of all residual jets in several planes, with their origins located relative to the device (medial, lateral, or through the device).
- Pulmonary venous flow, in which disappearance of baseline systolic flow reversal, or a return to systolic predominance, supports meaningful reduction and persistent systolic reversal indicates significant residual MR.
- Continuous-wave Doppler density and contour of the MR signal.
- Stroke volume in the left ventricular outflow tract, which rises after successful reduction of MR under similar loading conditions.
- Three-dimensional vena contracta area by MPR for the individual jets; misalignment overestimates it.
Anesthesia lowers afterload and makes residual MR look smaller, so the result is assessed with blood pressure near awake values.
Iatrogenic stenosis. Devices reduce orifice area. The mean transmitral gradient is measured by continuous-wave Doppler and reported with the heart rate. Orifice area is measured by three-dimensional MPR planimetry of the orifices one at a time, with the plane realigned for the orifice being measured, and the areas are summed. Pressure half-time is not used to estimate area after the procedure. The 2026 ASE guideline prefers a residual mean gradient below 5 mm Hg and a residual valve area of at least 2.0 cm², while noting that age and functional status influence the acceptable result (Little 2026). A decision on a second device weighs the residual MR against the gradient: a trial grasp measures both before commitment, and the report states both results with heart rates. A second device that eliminates moderate MR but more than doubles the gradient, to above 5 mm Hg, trades regurgitation for stenosis.
Left ventricular function commonly falls after abrupt elimination of MR because the regurgitant low-impedance outlet is closed; a new regional wall motion abnormality has other causes and is reported separately.
Iatrogenic atrial septal defect after transseptal procedures
Transseptal procedures leave a septal defect, and large-bore systems for mitral repair and replacement leave larger ones. After mitral edge-to-edge repair, persistent iatrogenic defects at 6 months are common: about 27% on TTE and nearly 50% on TEE (Little 2026). Larger catheter size, longer procedures, extensive sheath movement, high left atrial pressure, and left ventricular hypertrophy are associated with persistence. In one series, persistent defects after edge-to-edge repair were associated with worse clinical outcomes (Schueler 2015). In the randomized MITHRAS trial, routine device closure of a significant iatrogenic defect after mitral repair did not improve exercise capacity at short-term follow-up (Lurz 2021). The 2026 ASE guideline does not recommend routine closure (Little 2026).
At the end of the procedure the imager reports the size and shape of the defect (by three-dimensional MPR, reviewed in systole and diastole), the direction of shunting, and the right ventricular size. The 2026 ASE guideline lists right-to-left or bidirectional shunting, pulmonary hypertension, and new right ventricular dysfunction or severe TR as indications for closure at the time of the procedure (Little 2026). The guideline also states that defects larger than 1.0 cm are generally closed after case-by-case review. A large left-to-right shunt with right ventricular volume overload on follow-up is an indication for later closure. The defect also matters for later procedures, because it may provide or complicate future transseptal access.
Transcatheter mitral valve replacement and prediction of outflow obstruction
Transcatheter mitral replacement can be performed in a native valve, a failed surgical bioprosthesis (valve-in-valve), an annuloplasty ring (valve-in-ring), or severe mitral annular calcification (MAC; valve-in-MAC). In all these settings the new valve displaces the anterior mitral leaflet, or the leaflets of the surgical valve, toward the septum. The residual channel between the displaced leaflet or valve frame and the septum is the neo-left ventricular outflow tract (neo-LVOT). Its obstruction is the defining hazard of mitral replacement and is predicted by CT before the procedure. Devices available in the United States and their indications are on the mitral regurgitation page.
CT planning. The mitral annulus is saddle shaped, so its dimensions are measured on a three-dimensional reconstruction across systolic phases with the annular definition used by the planned device. Many workflows exclude the anterior horn near the aorto-mitral curtain and close the contour with a line between the fibrous trigones (the D-shaped annulus). The full saddle contour and the D-shaped contour give different areas in the same patient. For valve-in-valve and valve-in-ring procedures the surgical valve or ring is identified, including whether a ring is complete or incomplete and rigid or flexible. For valve-in-MAC procedures the circumferential extent, thickness, and continuity of calcium determine anchoring, and gaps near the trigones predict incomplete anchoring. The circumflex artery, which can lie within a few millimeters of the posterior annulus, and the coronary sinus are mapped. CT also defines the transseptal trajectory.
Neo-LVOT prediction. A virtual valve of the intended size and implant depth is placed in the CT dataset, and the cross-sectional area of the predicted neo-LVOT is measured at its smallest, usually in early to mid systole. In a validation study of a CT computer-aided design tool, a predicted neo-LVOT area of 189.4 mm² (1.89 cm²) or less predicted obstruction with 100% sensitivity and 96.8% specificity (Wang 2018). In a multicenter registry of 194 patients, an estimated neo-LVOT of 1.7 cm² or less predicted obstruction with 96.2% sensitivity and 92.3% specificity (Yoon 2019). No universal threshold applies; the risk depends on the device, the indication, implant depth, and the phase measured (Reid 2021).
| Factor | Effect on predicted neo-LVOT |
|---|---|
| Long anterior mitral leaflet | Displaced leaflet extends into the outflow tract; a major mechanism of obstruction in native-valve replacement |
| Acute aorto-mitral angle | Valve axis directed toward the septum narrows the channel |
| Basal septal hypertrophy and small cavity | Less distance from annulus to septum |
| Deeper ventricular implant and larger valve | Frame projects farther into the outflow tract; the same annulus can give an acceptable area at one depth and a high-risk area at a deeper one |
| Phase of measurement | The neo-LVOT is smallest in systole; a diastolic measurement underestimates risk |
| Valve-in-valve or valve-in-ring | Surgical leaflets are pinned open by the frame; risk depends on the surgical valve height and orientation |
Determinants of the predicted neo-left ventricular outflow tract, after the 2021 expert recommendations on neo-LVOT and transcatheter mitral replacement.
When the predicted neo-LVOT is small, mitigation includes intentional laceration of the anterior mitral leaflet with an electrified wire before implantation (LAMPOON, laceration of the anterior mitral leaflet to prevent outflow obstruction). Preemptive septal reduction by alcohol septal ablation or radiofrequency ablation is an alternative that enlarges the outflow tract over weeks. During the procedure, TEE guides transseptal access and deployment and then measures the outflow tract gradient, the transmitral gradient, paravalvular regurgitation, device stability, and the pericardium. A new outflow gradient after deployment is compared with the CT prediction and the baseline.
Tricuspid edge-to-edge repair and transcatheter tricuspid replacement
In the TRILUMINATE Pivotal trial of 350 patients with severe tricuspid regurgitation, edge-to-edge repair reduced TR severity and improved quality of life compared with medical therapy. At 1 year there was no difference in death, tricuspid surgery, or heart failure hospitalization (Sorajja 2023). In TRISCEND II, transcatheter tricuspid replacement with a self-expanding valve improved a hierarchical composite driven by symptoms and quality of life (Hahn 2025). The US Food and Drug Administration has approved both device types. The tricuspid valve is a difficult target for intraprocedural imaging, and imaging quality is a principal determinant of feasibility.
Screening. TTE and TEE establish the mechanism (primary leaflet disease, ventricular or atrial secondary TR, or lead-related TR), the number and arrangement of leaflets (more than three leaflets are common), and the coaptation gap and its location. They also measure annular dimensions, right ventricular size and function, and pulmonary artery pressure, and they show the relationship of pacemaker or defibrillator leads to the leaflets. A lead that impinges on the septal leaflet may occupy the planned grasping zone and is part of the planning question. A very large coaptation gap, dense chordae, and poor transesophageal windows reduce the feasibility of repair.
CT adds annular geometry in the phase required by a replacement device (the tricuspid annulus is dynamic, nonplanar, and usually dilated and elliptical in severe TR). It also maps the course of the right coronary artery in the atrioventricular groove next to the annulus and shows lead position. CT further defines right atrial and caval anatomy and the angle between the inferior vena cava and the annulus that governs the delivery trajectory. CT does not grade TR severity.
Intraprocedural imaging. The tricuspid valve lies in the far field of midesophageal TEE views and is shadowed by leads, calcium, and prosthetic mitral or aortic valves. Deep esophageal and transgastric views give the best en face and short-axis images of the leaflets, and transgastric short-axis imaging is often the primary view for grasping. Three-dimensional TEE, biplane imaging, and MPR are combined. When transesophageal views are inadequate, ICE from the right atrium (two- or three-dimensional) or TTE supplements them; three-dimensional ICE gives septal, anterior, and posterior leaflet views, with resolution somewhat below TEE (Leuzzi 2026). After the procedure, residual TR, the diastolic gradient, lead position and function, right ventricular function, and the pericardium are assessed. Residual TR is graded with the same multiparametric approach as after mitral repair, and an iatrogenic gradient is uncommon at the large tricuspid orifice. After replacement, paravalvular regurgitation, valve stability, and right ventricular afterload mismatch are assessed; right ventricular function can fall abruptly when severe TR is eliminated.
Left atrial appendage occlusion: planning, guidance, and surveillance
Percutaneous appendage occlusion places a self-expanding occluder (a plug-type device such as Watchman FLX or a lobe-and-disc device such as Amulet) in the appendage through transseptal access. Patient selection, trials, and antithrombotic therapy are on the atrial fibrillation page. The imaging rules come from the 2025 SCAI/HRS clinical practice guideline, which uses the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, and from the 2023 SCAI/HRS expert consensus statement (Goldsweig 2025; Saw 2023).
Before the procedure. The 2025 guideline suggests TEE or CT before the day of the procedure over omitting preprocedural imaging (conditional recommendation, very low certainty; Goldsweig 2025). Imaging excludes thrombus, selects the device and sheath, plans the transseptal puncture, and determines whether ICE can be used. TEE measures the ostium and landing zone at 0°, 45°, 90°, and 135° and the usable depth, and characterizes lobes and thrombus. CT gives three-dimensional landing-zone dimensions on double-oblique reconstructions at the device-specific level, measured in the phase of maximal appendage filling. Because the appendage may fill incompletely on the arterial phase and mimic thrombus, a delayed acquisition about 60 seconds after peak opacification distinguishes slow flow from thrombus, with reported sensitivity of 100% and specificity of 98% to 100% (Korsholm 2020). CT landing-zone dimensions are generally larger than TEE dimensions, so a sizing table built on one modality is not applied to the other. Volume loading enlarges the appendage, and underfilled measurements undersize the device. Morphology labels (chicken wing, windsock, cactus, cauliflower) aid communication but do not select a device (Jain 2025); landing-zone size, usable depth, lobe anatomy, and the axis of the appendage relative to the septum do.
During the procedure. The guideline suggests either ICE or TEE (conditional recommendation, low certainty), chosen by expertise, the anesthesia plan, and the ability to see the septum, device, and pericardium (Goldsweig 2025); fluoroscopy alone is inadequate. Imaging guides an inferior and posterior septal puncture, excludes thrombus, measures the landing zone, follows sheath position to avoid perforation of the thin appendage wall, and confirms device release criteria in several planes. For the Watchman FLX the release criteria are position, anchor (tug test), size (compression), and seal, summarized as PASS, and the recommended compression range is 10% to 30% (Nielsen-Kudsk 2023). For lobe-and-disc devices, the lobe is coaxial with the neck, the disc covers the ostium with concavity, and the lobe shows a tire shape under compression. Before release, the circumflex artery and left upper pulmonary vein are examined for impingement by a disc, color Doppler maps peridevice flow, and the pericardium is surveyed. Air embolism through large sheaths is a recognized risk under sedation and is prevented by careful de-airing.
After the procedure. A predischarge TTE detects effusion and device displacement or embolization. It cannot exclude device-related thrombus or grade peridevice leak. The 2025 guideline suggests follow-up TEE or CT over no follow-up imaging (conditional recommendation, very low certainty) without specifying timing (Goldsweig 2025). The 2023 consensus statement recommends TEE or CT at 45 to 90 days (Saw 2023), and many programs repeat imaging at about 1 year. A 2024 position statement from European and North American specialists recommends CT at 6 to 24 weeks and suggests a further study at 12 months (Korsholm 2024).
| Phase | Imaging question | Modality and method |
|---|---|---|
| Before | Thrombus | TEE multiplane sweep; CT with delayed acquisition about 60 seconds after peak opacification |
| Before | Landing zone and depth | TEE at four angles; CT double-oblique at the device-specific level in the phase of maximal filling |
| Before | Septum and trajectory | TEE or CT: septal thickness, prior devices, appendage axis |
| During | Puncture and sheath position | TEE or ICE: inferior–posterior tent; sheath tip within the appendage, away from the wall |
| During | Release criteria | Position, anchor, size (compression), and seal in several planes; impingement on circumflex artery, pulmonary vein, or mitral valve |
| During | Complications | Pericardial effusion; device instability; air embolism |
| Before discharge | Effusion, embolization | TTE |
| 45–90 days | Device-related thrombus, peridevice leak | TEE or CT |
Imaging for left atrial appendage occlusion, after the 2025 SCAI/HRS guideline, the 2023 SCAI/HRS consensus statement, and the 2020 CT planning recommendations.
Device-related thrombus and peridevice leak after appendage occlusion
Device-related thrombus is a discrete echodensity or low-attenuation mass on the atrial surface of the device, distinct from the device fabric and the normal healing layer, that persists in more than one plane. On TEE it is mobile or sessile and of soft-tissue density. On CT, a 2024 position statement grades hypoattenuated thickening by location, extent, morphology, and device design, and treats high-grade thickening (thickness greater than 3 mm, a pedunculated shape, or an irregular surface) as thrombus (Korsholm 2024). Low-grade thin, smooth thickening is considered part of endothelialization. A deep implant (more than 10 mm below the ridge between the appendage and the left upper pulmonary vein) leaves an uncovered pocket and is associated with thrombus. About one-third of device thrombi are diagnosed more than 6 months after implantation. The 2025 guideline suggests oral anticoagulation for device-related thrombus (conditional recommendation, very low certainty) and makes no recommendation about its duration or the timing of repeat imaging (Goldsweig 2025). Repeat imaging at 45- to 90-day intervals documents resolution in practice (Saw 2023).
Peridevice leak is flow around the device into the appendage. On TEE its width is measured with color Doppler in all imaging planes; leaks larger than 5 mm were considered significant in the original device trials and remain the threshold for "effective" closure in recent studies (Nielsen-Kudsk 2023). On CT, contrast in the appendage beyond the device indicates incomplete occlusion, and the leak is reported by location, area, and diameters. CT detects more and larger leaks than TEE. Malalignment of the device with the main lobe is the usual mechanism. Small leaks are associated with thromboembolic events in registry data, but the 2025 guideline identifies the management of leaks (anticoagulation, imaging frequency, or closure with plugs or coils) as a knowledge gap and makes no recommendation (Goldsweig 2025).
Atrial septal defect and patent foramen ovale closure: rims and device position
Device closure of a secundum atrial septal defect or patent foramen ovale is guided by TEE or ICE with fluoroscopy. Indications, anatomic selection, and complications are on the atrial septal defect and patent foramen ovale page; the imaging steps are described here.
Defect anatomy and rims. Imaging confirms a secundum defect (and excludes sinus venosus, primum, and coronary sinus defects and anomalous pulmonary venous drainage), measures the defect in several planes or by three-dimensional en face imaging, identifies multiple or fenestrated defects, and measures the rims of septal tissue surrounding the defect. The 2015 ASE/SCAI guideline names six rims: aortic (anterosuperior), superior vena caval (superior), posterior, inferior vena caval (inferior), atrioventricular valve (anteroinferior), and posterosuperior toward the right upper pulmonary vein (Silvestry 2015). A rim shorter than 5 mm is deficient, and a single defect larger than 38 mm is generally unsuitable for a device. A deficient retroaortic rim is common and usually acceptable, because the discs splay around the aorta, although an absent aortic rim combined with an oversized device is the setting most associated with erosion. Deficient inferior caval or posterior rims give less support and favor surgery. For a PFO, imaging measures tunnel length and the separation of septum primum from secundum, identifies an atrial septal aneurysm and a Eustachian valve or Chiari network, and confirms right-to-left shunting with agitated saline when needed.
Balloon sizing and deployment. A compliant balloon is inflated across the defect until color flow stops, and the waist is measured (stop-flow diameter). The imager then confirms four findings before release. The left atrial disc opens in the left atrium away from the mitral valve and pulmonary veins. The right atrial disc lies on the right side, with septal tissue between the discs on both edges in at least two orthogonal views (the "sandwich" sign). The discs do not impinge on the aortic root, the atrioventricular valves, the coronary sinus, or the venous inflows. The device is stable on a push–pull maneuver. After release, residual shunt, device position, and the pericardium are assessed, and later surveillance uses TTE with color Doppler or agitated saline. ICE views from the right atrium (the septal long-axis and aortic short-axis views) display the posterior and inferior rims and the aortic rim, respectively, and allow closure under conscious sedation.
Paravalvular leak closure: defect mapping and device guidance
Transcatheter closure of a paravalvular leak around a surgical mitral or aortic prosthesis requires a map of all defects. Percutaneous repair is reasonable at a Comprehensive Valve Center in patients with intractable hemolysis or New York Heart Association (NYHA) class III or IV symptoms who are at high or prohibitive surgical risk and have suitable anatomy (Class 2a; Otto 2021). Three-dimensional TEE is the standard method for mapping the defects and guiding the procedure (Zoghbi 2019; Little 2023). In the surgical en face view of a mitral prosthesis, with the aortic valve at 12 o'clock and the appendage at 9 o'clock, defects are assigned a clock-face position, length, width, and shape (often crescentic). The relation of the defects to the sewing ring, the leaflets or occluders of the prosthesis, and calcium is also described. Rocking of the prosthesis suggests a large dehiscence, and a new leak late after surgery raises the possibility of endocarditis, which is excluded first. CT complements TEE for complex, calcified, or aortic defects and for planning the access route (antegrade transseptal, retrograde across the aortic valve, or transapical).
During the procedure, three-dimensional TEE guides wire crossing of the defect, shows the delivery sheath and occluder (most often a vascular plug), and confirms residual regurgitation, the transprosthetic gradient, and free leaflet or occluder motion before release. An occluder can impinge on a mechanical disc or bioprosthetic leaflet. Grading of paravalvular regurgitation and the indications for closure are on the prosthetic heart valves page.
Balloon mitral valvuloplasty and the Wilkins score
Percutaneous balloon mitral commissurotomy splits fused commissures in rheumatic mitral stenosis. It suits pliable leaflets with little calcium, no more than mild MR, and no left atrial thrombus. The 2020 American College of Cardiology/American Heart Association (ACC/AHA) guideline recommends it for symptomatic severe rheumatic mitral stenosis with favorable morphology, less than moderate MR, and no left atrial thrombus, at a Comprehensive Valve Center (Class 1; Otto 2021). Calcific (degenerative) stenosis has no fused commissure to split and does not respond.
Before the procedure, TEE with a multiplane sweep of the appendage excludes thrombus, and the valve is scored. The Wilkins score grades four features on a scale of 1 to 4, for a total of 4 to 16 (Wilkins 1988) (morphology scores in mitral stenosis).
| Feature | Grade 1 | Grade 2 | Grade 3 | Grade 4 |
|---|---|---|---|---|
| Leaflet mobility | Highly mobile; only leaflet tips restricted | Mid and basal portions normal mobility | Valve moves forward in diastole, mainly from the base | No or minimal forward movement in diastole |
| Leaflet thickening | Near normal (4–5 mm) | Mid-leaflets normal; margins thickened (5–8 mm) | Thickening throughout the leaflet (5–8 mm) | Considerable thickening of all leaflet tissue (>8–10 mm) |
| Subvalvular thickening | Minimal, just below the leaflets | Up to one-third of chordal length | Extending to the distal third of the chords | Extensive thickening and shortening of all chords to the papillary muscles |
| Calcification | Single area of increased brightness | Scattered bright areas at leaflet margins | Brightness extending into the mid-leaflets | Extensive brightness throughout much of the leaflet |
Wilkins echocardiographic score for balloon mitral valvuloplasty (Wilkins 1988). In a later series of 879 patients, a total of 8 or less was associated with the best immediate and long-term results (Palacios 2002).
The score omits commissural calcification and preexisting MR, which predict a poor split and severe regurgitation after dilation, so two valves with equal totals can differ in suitability; asymmetric or bilateral commissural calcium is reported separately. During the procedure, TEE or ICE guides transseptal puncture and balloon position. After an inflation, imaging measures the mean gradient, the valve area by planimetry, commissural splitting, and new or worsening MR. Dilation stops when the commissures are split and the valve area is adequate, or earlier when MR increases. Severe MR from leaflet tear and tamponade are the principal complications. Pressure half-time is unreliable immediately after dilation because atrial and ventricular compliance change abruptly.
Alcohol septal ablation, pericardiocentesis, and endomyocardial biopsy
Alcohol septal ablation for obstructive hypertrophic cardiomyopathy (candidacy and outcomes on the hypertrophic cardiomyopathy page) uses myocardial contrast echocardiography to choose the septal perforator. An ultrasound-enhancing agent injected into the candidate branch opacifies its territory before alcohol is given. A suitable branch opacifies the basal septum at the point of mitral–septal contact. Opacification of a papillary muscle, the right ventricle, the moderator band, or a distant wall excludes the branch. Afterward, imaging reassesses the gradient, systolic anterior motion, MR, and the pericardium, and the resting and provoked gradients fall further over weeks as the septum thins.
Pericardiocentesis is guided by TTE: the site is chosen where the collection is thickest and nearest the skin, with no interposed liver, lung, or internal mammary vessel. Agitated saline through the needle opacifies the pericardial space when the needle is correctly placed; opacification of the right ventricle indicates an intracardiac needle. The technique is on the pericardial effusion and tamponade page.
Endomyocardial biopsy and electrophysiology procedures use echocardiography or ICE to localize catheters and detect complications. A new effusion is treated as perforation until another cause is shown, and new severe TR after right ventricular biopsy suggests chordal or leaflet injury.
Pericardial effusion and other complications during structural procedures
A change in hemodynamics during any structural procedure prompts a survey for all complications, because hypotension after septal closure, for example, can reflect tamponade, device embolization, or new obstruction. The imager compares the findings with the baseline images recorded before the first catheter crossed the septum or valve.
| Complication | Echocardiographic findings | Typical settings |
|---|---|---|
| Pericardial effusion and tamponade | New or enlarging effusion; right atrial and right ventricular diastolic collapse; plethoric inferior vena cava | Transseptal puncture, appendage sheaths, wires in the left ventricle, ablation, biopsy |
| Device embolization | Device absent from its site or displaced into a chamber or vessel | Appendage occlusion, septal closure, TAVR |
| New valve lesion | New regurgitant jet; rise in gradient from baseline | Valve repair or replacement; wire or device entanglement |
| Coronary compromise | New regional wall motion abnormality in a coronary distribution | TAVR, mitral procedures near the circumflex, air |
| Chamber or aortic injury | Intimal flap, hematoma, new jet between chambers, or effusion | TAVR, large sheaths, balloon dilation |
| Air embolism | Mobile bright echoes in the left heart; inferior wall and right ventricular dysfunction when air enters the right coronary artery | Large-bore sheaths, catheter exchanges |
| Dynamic outflow obstruction | Systolic anterior motion; late-peaking outflow jet | Mitral replacement, hypovolemia, inotropes, small hypertrophied ventricle |
| Thrombus on catheters or devices | Mobile echodensity on sheaths or device surfaces | Long left atrial procedures; subtherapeutic anticoagulation |
| Iatrogenic atrial septal defect | Septal defect with shunt; direction by color Doppler | All transseptal procedures |
Complications of structural procedures and their echocardiographic findings.
Pericardial effusion is the most important. A small effusion present at baseline is documented before the procedure, so that a new effusion is recognized. Effusion detected during a procedure is measured, monitored at intervals, and reported at once when it enlarges. Its location (posterior, around the right atrium, or localized) is described. The transgastric view or ICE from the right ventricle shows it during TEE- or ICE-guided procedures. Tamponade from perforation during an anticoagulated procedure can develop within minutes.
Shadowing, reverberation, and other device artifacts
Metal frames, occluder discs, catheters, and calcium reflect almost all ultrasound energy, so the region beyond them is shadowed, and a finding that is not seen within a shadow cannot be considered absent. A mitral bioprosthesis or ring shadows the left ventricular outflow tract on TEE and the left atrium on TTE, which is why the transthoracic and transesophageal approaches are complementary after mitral procedures. Catheters and wires produce parallel reverberation lines and side-lobe artifacts that can mimic thrombus, a flap, or a septal defect. A reverberation moves with the catheter and disappears with a slight change in angle, whereas thrombus keeps its attachment and borders in several planes. ICE images show near-field saturation that obscures tissue close to the transducer. Three-dimensional datasets add dropout (thin leaflets or septum disappear at low gain and resemble perforations or defects), blooming of metal and calcium (devices appear thicker), and stitching artifacts. Color Doppler beyond a device is attenuated, and flow acceleration around a device can be mistaken for a leak. Imaging from a second window, a change of plane, and reduction of gain or use of a narrower sector distinguish artifact from anatomy. Artifacts on transesophageal imaging are covered on the transesophageal echocardiography page.
Cardiac magnetic resonance before structural intervention
Cardiac magnetic resonance (CMR) supplements echocardiography when severity, ventricular size, or tissue character determines candidacy. It quantifies regurgitant volume and fraction by combining phase-contrast flow with volumetric measurements, and it measures left and right ventricular volumes and ejection fraction without geometric assumptions. In chronic primary MR, CMR is indicated (Class 1) to assess ventricular volumes, function, or MR severity when TTE is insufficient (Otto 2021). Before tricuspid interventions, right ventricular volumes and ejection fraction by CMR describe the ventricle that will receive the full stroke volume after regurgitation is eliminated. Late gadolinium enhancement identifies scar and fibrosis that influence expected recovery. In hypertrophic cardiomyopathy, CMR also shows septal thickness, mitral apparatus anomalies, and scar before the choice between myectomy and alcohol septal ablation. CMR can also measure aortic regurgitation by phase-contrast flow in the ascending aorta.
CMR has limits in this population: arrhythmia degrades gated acquisitions, many patients have pacemakers or defibrillators (devices labeled as conditional for magnetic resonance imaging permit scanning under defined conditions), and metal frames and occluders cause susceptibility artifacts that obscure adjacent structures after the procedure. CMR does not replace CT for annular sizing, coronary heights, or access.
Follow-up imaging after structural procedures
Follow-up imaging establishes a baseline, detects device-specific complications, and documents remodeling.
| Procedure | Baseline and early study | Later imaging | Principal findings sought |
|---|---|---|---|
| TAVR | TTE within the first weeks at stable loading | TTE at 1 year and then annually; multiphase CT when leaflet thrombosis is suspected | Gradient and effective orifice area against baseline, paravalvular regurgitation, leaflet thickening and motion, structural valve deterioration |
| Mitral edge-to-edge repair | TTE before discharge and at 30 days | TTE at 1 year and annually | Residual or recurrent MR, gradient, device detachment, iatrogenic septal defect, left ventricular remodeling |
| Transcatheter mitral replacement | TTE | TTE; CT for leaflet thrombosis | Gradients, outflow obstruction, paravalvular regurgitation, thrombosis |
| Tricuspid repair or replacement | TTE | TTE | Residual TR, gradient, right ventricular function, lead function |
| Left atrial appendage occlusion | TTE before discharge | TEE or CT at 45–90 days; often at 1 year | Device-related thrombus, peridevice leak, device position |
| ASD or PFO closure | TTE before discharge | TTE with color Doppler or agitated saline at 6–12 months | Residual shunt, device position, erosion (new effusion), right ventricular size |
Typical imaging schedule after structural procedures, after the 2020 ACC/AHA valve guideline, the 2024 ASE prosthetic valve guideline, and the 2023 SCAI/HRS appendage consensus statement. Surveillance after valve replacement is detailed on the prosthetic valve page.
After TAVR, hypoattenuated leaflet thickening on contrast CT, graded by the fraction of the leaflet involved (in quartiles), with or without reduced leaflet motion, represents thin leaflet thrombus. Routine CT screening is not performed. CT is obtained when the mean gradient rises or an embolic event occurs. A high gradient is not attributed to structural deterioration until leaflet thickening and motion have been imaged, because thrombosis responds to anticoagulation. The diagnosis and treatment are on the prosthetic heart valves page. After mitral repair, a rising gradient with leaflet restriction or new MR from partial device detachment is the principal late finding, and TEE defines the mechanism.
Content of the procedural imaging report and handoff
The written report of a guided procedure states the procedure and device, the imaging modality, baseline findings, all measurements with heart rate, blood pressure, and vasoactive drugs, the result, all complications including those resolved, and the limitations of the study. A mitral edge-to-edge repair report gives the number and location of devices, the residual MR and its location, the mean gradient with heart rate, the orifice area by MPR, the pulmonary venous flow pattern, the iatrogenic septal defect with its shunt direction, and the pericardial status. A TAVR report gives valve position and depth, the gradient, paravalvular regurgitation with its location and circumferential extent, ventricular function, and the pericardium. An appendage occlusion report gives the device and size, compression, seal, any peridevice flow with its width, and the pericardium.
A procedure-ready CT planning report reads: "Annular area 430 mm² and perimeter 75 mm at the 30% phase; left main height 9 mm; mean sinus diameter 27 mm; bulky calcium in the left coronary cusp extending below the annulus; common femoral minimum lumen 6.1 mm on the right with posterior calcium." Numbers without phase or plane cannot be reproduced. Critical findings, such as a displaced leaflet covering the left main ostium on a postprocedural CT, are communicated immediately. The handoff to the recovery or intensive care team repeats all findings that change management.
Training, competency, and certification in interventional echocardiography
The 2023 ASE recommendations define special competency in echocardiographic guidance of structural interventions (Little 2023). Cardiology trainees enter interventional echocardiography training after a 3-year general cardiology fellowship. They have met the procedural volume for level II competency in adult echocardiography and have achieved, or are eligible for, National Board of Echocardiography testamur status. Anesthesiology trainees enter after 12 months of adult cardiothoracic anesthesiology fellowship. The recommended pathway for cardiology trainees is an additional 9 to 12 months of advanced echocardiography training. Training is competency based: procedure-specific knowledge, skills, and communication are assessed by supervising faculty, and the stated volumes are minimums based on consensus.
| Procedure or skill | Minimum number |
|---|---|
| Echocardiographic guidance of interventional procedures (total) | 75 |
| Structural valvular interventions | 30 |
| Transseptal catheterization guidance | 10 |
| Percutaneous closure of septal defects and paravalvular leaks | 15 |
| Alcohol septal ablation | 10 |
| Left atrial appendage exclusion devices | 10 |
| Intraoperative TEE (total) | 75 |
| Surgical valve repair or replacement | 50 |
| Ventricular assist device placement and assessment | 20 |
| Intracardiac echocardiography | 10 |
Minimum procedural volumes for level III interventional echocardiography, from the 2019 ACC/AHA/ASE advanced training statement as reproduced in the 2023 ASE recommendations. Additional supervised cases are needed for complex anatomy and new devices.
Simulation and three-dimensional models support training in transseptal puncture and device steering. Interventional cardiologists who perform ICE-guided procedures acquire imaging competence by the same competency-based approach: the operator must recognize views, artifacts, and complications without a separate imager.
Radiation exposure and ergonomics of the interventional imager
The interventional echocardiographer stands at the head of the table, close to the x-ray tube and the scatter from the patient, often without the table-mounted and ceiling-mounted shields that protect the operator. In a study of 60 appendage occlusion and mitral repair procedures, the median personal dose equivalent per case was 10.6 μSv for interventional echocardiographers compared with 2.1 μSv for interventional cardiologists. The imager's dose was about 3-fold the operator's dose during appendage occlusion and 11.7-fold during mitral repair (McNamara 2022). An earlier study found that TEE operators received doses at least as high as the primary operator and that an additional ceiling-suspended lead shield significantly reduced their dose (Crowhurst 2018).
The 2023 ASE recommendations call for radiation safety training and the "as low as reasonably achievable" principle for all interventional imagers. The recommended equipment is a lead apron with at least 0.25-mm lead equivalence at the back and 0.5 mm at the front, a thyroid collar, lead goggles, and a personal dosimeter that is regularly monitored and reported. A ceiling-suspended or mobile lead acrylic shield of 0.5-mm lead equivalence is placed between the imager and the tube (Little 2023). Greater distance from the tube, positioning outside the primary beam, avoidance of steep angulations when the imager is on the tube side, and collimation by the operator reduce exposure further. ICE removes the imager from the field for appendage and septal procedures.
Ergonomic hazards are the second occupational burden. Imagers stand for hours in lead, hold a TEE probe with a sustained grip and the arm abducted over the patient around the C-arm and drapes, and rotate the neck toward monitors placed for the operator. In a multisite survey of 1,543 employees, workers involved in procedures using radiation reported work-related musculoskeletal pain more often than unexposed colleagues, and the burden was highest among nonphysician staff (Orme 2015). Lighter two-piece or suspended lead systems, a dedicated monitor at the imager's eye level, a stool or support for the probe arm, rotation of imaging responsibility in long cases, and placement of the echocardiography machine within reach reduce strain. The 2023 ASE competency document lists ergonomic considerations among the skills required of the interventional echocardiographer (Little 2023).
Coding and reimbursement for structural imaging
In the United States, real-time TEE guidance of a transcatheter intracardiac or great vessel structural intervention is reported with Current Procedural Terminology (CPT) code 93355. The code is reported once per intervention, and only by a physician who is not performing the interventional procedure. It includes probe placement, real-time image acquisition and interpretation, Doppler, color flow, three-dimensional imaging, and contrast when performed. The documentation names the indication, the specific structural intervention, and the imaging findings and measurements (ASE coding review). ICE is reported with an add-on code by the physician who performs it. The 2025 SCAI position statement argues that current add-on coding does not reflect the complexity of ICE-guided structural procedures or the role of the interventional imager (Eleid 2025).
The cost of single-use ICE catheters is balanced against the costs of general anesthesia, an anesthesia team, a second imaging physician, and recovery time with TEE; the net effect depends on local staffing and practice (Leuzzi 2026). The time an interventional echocardiographer spends in long procedures, often away from other clinical work, is also a workforce and staffing issue for structural heart programs.
Sources of error in structural interventional imaging
- An annulus measured on a scanner axial image or an oblique plane: the ellipse is larger than the true annulus, and the valve may be oversized. The annulus is measured in the double-oblique plane through the three basal hinge points.
- A fixed diastolic phase for annular sizing: the annulus is smaller in diastole, and an undersized valve risks paravalvular regurgitation. The largest adequate annulus, usually systolic, is measured.
- Mixing measurement types: area oversizing compared with a perimeter-based target, or the mean diameter of an oval annulus used to select the valve.
- Coronary height measured along the curved aortic wall: the value is falsely high, and a low ostium is missed. Height is measured perpendicular to the annular plane to the lower edge of the ostium.
- A total calcium score reported without location: subannular calcium near the membranous septum or below the left coronary cusp predicts rupture and conduction injury and is described by site.
- The labeled size of a surgical valve used as its internal diameter in valve-in-valve planning.
- A neo-LVOT measured in diastole, at a shallower simulated depth than intended, or with a different device: the risk of obstruction is underestimated.
- Capture of both leaflets inferred from a smaller color jet in one plane: single-leaflet attachment coexists with a smaller jet. Insertion is confirmed by the four anatomic signs in more than one view.
- Grading residual MR after edge-to-edge repair by jet area or a single vena contracta: multiple eccentric jets and shadowing make these unreliable, and anesthesia lowers afterload. Pulmonary venous flow, continuous-wave density, stroke volume, and three-dimensional vena contracta area are integrated at near-awake blood pressure.
- A transmitral gradient reported without heart rate, or orifice area by pressure half-time after a device: neither result can be interpreted.
- One transseptal site for all procedures: a high posterior puncture suits mitral repair but misaligns the appendage sheath; a low puncture makes mitral steering impossible.
- An early filling defect on arterial-phase CT diagnosed as appendage thrombus without a delayed acquisition: slow flow mimics thrombus and leads to unnecessary cancellation.
- Applying a TEE-based appendage sizing table to CT diameters, or sizing from an underfilled appendage.
- Reliance on predischarge TTE to exclude device-related thrombus or peridevice leak after appendage occlusion.
- An echodensity seen only in the near field of an ICE image, or one that moves with the catheter, interpreted as thrombus: reverberation and near-field saturation are excluded by changing the angle and plane.
- Absence of a finding within the acoustic shadow of a frame, ring, or occluder taken as evidence of absence.
- Attributing hypotension after TAVR to mild paravalvular regurgitation without a survey for effusion, wall motion abnormality, dissection, and mitral injury.
- A new effusion during a procedure not compared with a recorded baseline, so that a preexisting effusion is misread as perforation or a new one is missed.
References
- Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143:e72–e227. doi:10.1161/CIR.0000000000000923
- Little SH, Rigolin VH, Garcia-Sayan E, et al. Recommendations for special competency in echocardiographic guidance of structural heart disease interventions: from the American Society of Echocardiography. J Am Soc Echocardiogr. 2023;36:350–365. doi:10.1016/j.echo.2023.01.014
- Little SH, Quader N, Brady M, et al. Guidelines for the intraprocedural imaging for mitral valve transcatheter edge-to-edge repair (M-TEER): recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026;39:529–550. doi:10.1016/j.echo.2026.03.003
- Hahn RT, Saric M, Faletra FF, et al. Recommended standards for the performance of transesophageal echocardiographic screening for structural heart intervention: from the American Society of Echocardiography. J Am Soc Echocardiogr. 2022;35:1–76. doi:10.1016/j.echo.2021.07.006
- Zoghbi WA, Asch FM, Bruce C, et al. Guidelines for the evaluation of valvular regurgitation after percutaneous valve repair or replacement: a report from the American Society of Echocardiography. J Am Soc Echocardiogr. 2019;32:431–475. doi:10.1016/j.echo.2019.01.003
- Zoghbi WA, Jone PN, Chamsi-Pasha MA, et al. Guidelines for the evaluation of prosthetic valve function with cardiovascular imaging: a report from the American Society of Echocardiography. J Am Soc Echocardiogr. 2024;37:2–63. doi:10.1016/j.echo.2023.10.004
- Silvestry FE, Cohen MS, Armsby LB, et al. Guidelines for the echocardiographic assessment of atrial septal defect and patent foramen ovale: from the American Society of Echocardiography and Society for Cardiac Angiography and Interventions. J Am Soc Echocardiogr. 2015;28:910–958. doi:10.1016/j.echo.2015.05.015
- Nicoara A, Skubas N, Ad N, et al. Guidelines for the use of transesophageal echocardiography to assist with surgical decision-making in the operating room: a surgery-based approach. J Am Soc Echocardiogr. 2020;33:692–734. doi:10.1016/j.echo.2020.03.002
- Blanke P, Weir-McCall JR, Achenbach S, et al. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr. 2019;13:1–20. doi:10.1016/j.jcct.2018.11.008
- Généreux P, Piazza N, Alu MC, et al. Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research. J Am Coll Cardiol. 2021;77:2717–2746. doi:10.1016/j.jacc.2021.02.038
- Goldsweig AM, Glikson M, Joza J, et al. 2025 SCAI/HRS clinical practice guidelines on transcatheter left atrial appendage occlusion. J Soc Cardiovasc Angiogr Interv. 2025;4:103783. doi:10.1016/j.jscai.2025.103783
- Saw J, Holmes DR, Cavalcante JL, et al. SCAI/HRS expert consensus statement on transcatheter left atrial appendage closure. J Soc Cardiovasc Angiogr Interv. 2023;2:100577. doi:10.1016/j.jscai.2022.100577
- Korsholm K, Berti S, Iriart X, et al. Expert recommendations on cardiac computed tomography for planning transcatheter left atrial appendage occlusion. JACC Cardiovasc Interv. 2020;13:277–292. doi:10.1016/j.jcin.2019.08.054
- Korsholm K, Iriart X, Saw J, et al. Position statement on cardiac computed tomography following left atrial appendage occlusion. JACC Cardiovasc Interv. 2024;17:1747–1764. doi:10.1016/j.jcin.2024.04.050
- Jain R, Wessly P, Saric M, et al. Multimodality imaging in evaluating and guiding percutaneous left atrial appendage occlusion. J Am Soc Echocardiogr. 2025;38:1198–1218. doi:10.1016/j.echo.2025.07.009
- Eleid MF, Chung CJ, Daniels MJ, et al. SCAI position statement on intracardiac echocardiography to guide structural heart disease interventions. J Soc Cardiovasc Angiogr Interv. 2025;4:103946. doi:10.1016/j.jscai.2025.103946
- Leuzzi F, Formisano C, Cerrato E, et al. Intracardiac echocardiography in structural heart interventions: a comprehensive overview. J Clin Med. 2026;15:926. doi:10.3390/jcm15030926
- Nielsen-Kudsk JE, Berti S, Caprioglio F, et al. Intracardiac echocardiography to guide Watchman FLX implantation: the ICE LAA study. JACC Cardiovasc Interv. 2023;16:643–651. doi:10.1016/j.jcin.2022.10.024
- Ferro EG, Alkhouli M, Nair DG, et al. Intracardiac vs transesophageal echocardiography for left atrial appendage occlusion with Watchman FLX in the U.S. JACC Clin Electrophysiol. 2023;9:2587–2599. doi:10.1016/j.jacep.2023.08.004
- Yaser H, Yaser S, Mohammed HE, et al. Intracardiac versus transesophageal echocardiography for left atrial appendage occlusion: a meta-analysis. JACC Adv. 2026;5:102815. doi:10.1016/j.jacadv.2026.102815
- Thiele H, Kurz T, Feistritzer HJ, et al. General versus local anesthesia with conscious sedation in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. Circulation. 2020;142:1437–1447. doi:10.1161/CIRCULATIONAHA.120.046451
- Freitas-Ferraz AB, Bernier M, Vaillancourt R, et al. Safety of transesophageal echocardiography to guide structural cardiac interventions. J Am Coll Cardiol. 2020;75:3164–3173. doi:10.1016/j.jacc.2020.04.069
- Ribeiro HB, Webb JG, Makkar RR, et al. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol. 2013;62:1552–1562. doi:10.1016/j.jacc.2013.07.040
- Barbanti M, Yang TH, Rodès Cabau J, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128:244–253. doi:10.1161/CIRCULATIONAHA.113.002947
- Hamdan A, Guetta V, Klempfner R, et al. Inverse relationship between membranous septal length and the risk of atrioventricular block in patients undergoing transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2015;8:1218–1228. doi:10.1016/j.jcin.2015.05.010
- Lederman RJ, Babaliaros VC, Rogers T, et al. Preventing coronary obstruction during transcatheter aortic valve replacement: from computed tomography to BASILICA. JACC Cardiovasc Interv. 2019;12:1197–1216. doi:10.1016/j.jcin.2019.04.052
- Wang DD, Eng MH, Greenbaum AB, et al. Validating a prediction modeling tool for left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). Catheter Cardiovasc Interv. 2018;92:379–387. doi:10.1002/ccd.27447
- Yoon SH, Bleiziffer S, Latib A, et al. Predictors of left ventricular outflow tract obstruction after transcatheter mitral valve replacement. JACC Cardiovasc Interv. 2019;12:182–193. doi:10.1016/j.jcin.2018.12.001
- Reid A, Ben Zekry S, Turaga M, et al. Neo-LVOT and transcatheter mitral valve replacement: expert recommendations. JACC Cardiovasc Imaging. 2021;14:854–866. doi:10.1016/j.jcmg.2020.09.027
- Faza NN, Harb SC, Wang DD, et al. Physical and computational modeling for transcatheter structural heart interventions. JACC Cardiovasc Imaging. 2024;17:428–440. doi:10.1016/j.jcmg.2024.01.014
- Schueler R, Öztürk C, Wedekind JA, et al. Persistence of iatrogenic atrial septal defect after interventional mitral valve repair with the MitraClip system: a note of caution. JACC Cardiovasc Interv. 2015;8:450–459. doi:10.1016/j.jcin.2014.10.024
- Lurz P, Unterhuber M, Rommel KP, et al. Closure of iatrogenic atrial septal defect after transcatheter mitral valve repair: the randomized MITHRAS trial. Circulation. 2021;143:292–294. doi:10.1161/CIRCULATIONAHA.120.051989
- Sorajja P, Whisenant B, Hamid N, et al. Transcatheter repair for patients with tricuspid regurgitation. N Engl J Med. 2023;388:1833–1842. doi:10.1056/NEJMoa2300525
- Hahn RT, Makkar R, Thourani VH, et al. Transcatheter valve replacement in severe tricuspid regurgitation. N Engl J Med. 2025;392:115–126. doi:10.1056/NEJMoa2401918
- Wilkins GT, Weyman AE, Abascal VM, et al. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J. 1988;60:299–308. doi:10.1136/hrt.60.4.299
- Crowhurst JA, Scalia GM, Whitby M, et al. Radiation exposure of operators performing transesophageal echocardiography during percutaneous structural cardiac interventions. J Am Coll Cardiol. 2018;71:1246–1254. doi:10.1016/j.jacc.2018.01.024
- McNamara DA, Chopra R, Decker JM, et al. Comparison of radiation exposure among interventional echocardiographers, interventional cardiologists, and sonographers during percutaneous structural heart interventions. JAMA Netw Open. 2022;5:e2220597. doi:10.1001/jamanetworkopen.2022.20597
- Orme NM, Rihal CS, Gulati R, et al. Occupational health hazards of working in the interventional laboratory: a multisite case control study of physicians and allied staff. J Am Coll Cardiol. 2015;65:820–826. doi:10.1016/j.jacc.2014.11.056
- Pontes ÍCM, Guimarães CPBF, Fonseca EKUN, et al. Computed tomography angiography in the planning of transcatheter aortic valve replacement: a step-by-step approach. Radiol Bras. 2022;55:373–379. doi:10.1590/0100-3984.2021.0156
- American Society of Echocardiography. Interventional transesophageal echocardiography: background and coding review. 2021. asecho.org
- Shatila W, Krajcer Z. A cardiologist's nightmare: coronary obstruction during transcatheter aortic valve implantation: how to identify patients at highest risk for this complication. Catheter Cardiovasc Interv. 2017;90:1198–1199. doi:10.1002/ccd.27425
- Palacios IF, Sanchez PL, Harrell LC, et al. Which patients benefit from percutaneous mitral balloon valvuloplasty? Prevalvuloplasty and postvalvuloplasty variables that predict long-term outcome. Circulation. 2002;105:1465–1471. doi:10.1161/01.cir.0000012143.27196.f4
- De Ponti R, Cappato R, Curnis A, et al. Trans-septal catheterization in the electrophysiology laboratory: data from a multicenter survey spanning 12 years. J Am Coll Cardiol. 2006;47:1037–1042. doi:10.1016/j.jacc.2005.10.046
- Katritsis GD, Siontis GC, Giazitzoglou E, et al. Complications of transseptal catheterization for different cardiac procedures. Int J Cardiol. 2013;168:5352–5354. doi:10.1016/j.ijcard.2013.08.004
- Wasmer K, Zellerhoff S, Köbe J, et al. Incidence and management of inadvertent puncture and sheath placement in the aorta during attempted transseptal puncture. Europace. 2017;19:447–457. doi:10.1093/europace/euw037