Transcatheter aortic valve replacement

Transcatheter aortic valve replacement in adults from referral and planning through valve choice, access, procedure, complications, aftercare, reintervention, lifetime management, and US coverage rules.

Transcatheter aortic valve replacement (TAVR) implants a bioprosthetic valve inside the diseased native valve or a failed bioprosthesis through a catheter, most often from the femoral artery. In the 2020 American College of Cardiology/American Heart Association (ACC/AHA) guideline, transfemoral TAVR is recommended in preference to surgery for symptomatic severe aortic stenosis in patients older than 80 years with suitable anatomy. Either procedure is recommended between 65 and 80 years after shared decision-making. A heart team plans the procedure with computed tomography (CT) gated to the electrocardiogram (ECG), chooses the valve and access route, and anticipates conduction injury, coronary obstruction, and later reintervention before the first valve is placed.

Development of transcatheter aortic valve replacement

The first human transcatheter aortic valve was implanted in 2002 in a 57-year-old man with calcific aortic stenosis, cardiogenic shock, and multiple noncardiac illnesses for whom surgery had been declined and balloon valvuloplasty had failed. The device, three bovine pericardial leaflets sewn inside a balloon-expandable stent, was delivered antegrade through a transseptal puncture. It functioned well for 4 months, and the patient died of noncardiac complications 17 weeks after implantation (Cribier 2002). The retrograde transfemoral route, the transapical route, and a self-expanding nitinol platform followed within a few years.

US approval tracked the randomized trials. The balloon-expandable valve was approved in 2011 for patients who could not undergo surgery (PARTNER 1B) and in 2012 for high surgical risk (PARTNER 1A); approval of the self-expanding valve followed the CoreValve US Pivotal trials. Intermediate-risk approval came in 2016 for the balloon-expandable SAPIEN XT and SAPIEN 3 valves and in 2017 for the self-expanding Evolut platform, after PARTNER 2A and SURTAVI. In 2019, both platforms were approved for patients at low surgical risk after PARTNER 3 and Evolut Low Risk. In May 2025, the SAPIEN 3 family became the first transcatheter valve approved for asymptomatic severe aortic stenosis, on the basis of EARLY TAVR. In March 2026, a dedicated valve (JenaValve Trilogy) became the first approved for symptomatic severe native aortic regurgitation at high surgical risk.

Device generations changed the complication profile more than the concept. Lower-profile delivery systems moved most procedures to percutaneous transfemoral access; outer sealing skirts reduced paravalvular regurgitation; repositionable and recapturable self-expanding systems improved positioning; and CT-based sizing replaced two-dimensional echocardiographic annular diameters. Mechanically expanded valves (Lotus) produced little paravalvular regurgitation but high pacemaker rates and were withdrawn from the market in 2020. The ACURATE neo2 valve failed noninferiority against commercial valves in a randomized trial and was withdrawn worldwide in 2025.

Growth of TAVR relative to surgical aortic valve replacement in the United States

The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) Registry records US TAVR procedures; from 2011 to 2019 it collected data on 276,316 patients at sites in all US states. TAVR volume increased annually and in 2019 exceeded the volume of all forms of surgical aortic valve replacement (SAVR) (72,991 versus 57,626 procedures). In that year, femoral access was used in 95.3% of procedures, the median hospital stay was 2 days, and 90.3% of patients were discharged home. Between 2011 and 2019, 30-day mortality fell from 7.2% to 2.5% and stroke from 2.75% to 2.3%, whereas the need for a new pacemaker was unchanged (10.9% and 10.8%) (Carroll 2020).

Contemporary registry patients are younger and at lower predicted risk than in the early years. Among 210,495 patients treated at 786 US hospitals from 2019 to March 2022, the median age was 79 years, 43.4% were women, and the median STS predicted risk of mortality (STS PROM) was 3.3%. Unadjusted 30-day mortality was 2.4% at the start of that period and 2.2% at its end. After adjustment for patient and procedural factors, the odds of 30-day death increased modestly (odds ratio 1.09 per year), and no site, patient, or process factor explained the change (Arnold 2024). The growth of TAVR in younger and lower-risk patients is the reason durability, coronary access, and the second valve now enter the planning of the first.

Indications for TAVR and the choice between TAVR and SAVR

TAVR treats severe aortic stenosis that meets an indication for aortic valve replacement. The indications themselves (symptomatic severe stenosis, stage C2 disease, and the asymptomatic triggers), the grading of low-flow, low-gradient stenosis, and the use of the aortic valve calcium score in discordant grading are on the aortic stenosis page. The choice between SAVR and TAVR, with the anatomic and clinical factors that favor one procedure, is covered under surgical versus transcatheter aortic valve replacement. The 2020 ACC/AHA guideline assigns patients to SAVR or TAVR by age, life expectancy, and anatomy.

Patient group (bioprosthesis appropriate)2020 ACC/AHA recommendationClass (level of evidence)
Younger than 65 years or life expectancy more than 20 yearsSAVR1 (A)
65 to 80 years, no anatomic contraindication to transfemoral TAVREither SAVR or transfemoral TAVR after shared decision-making about longevity and durability1 (A)
Older than 80 years, or younger with life expectancy less than 10 years, no anatomic contraindicationTransfemoral TAVR in preference to SAVR1 (A)
High or prohibitive surgical risk at any ageTAVR if predicted post-TAVR survival exceeds 12 months with acceptable quality of life1 (A)
Valve or vascular anatomy unsuitable for transfemoral TAVRSAVR1 (A)
Predicted survival less than 12 months or minimal expected improvement in quality of lifePalliative care after shared decision-making1 (C-LD)

Choice of aortic valve replacement in symptomatic severe aortic stenosis in the 2020 ACC/AHA valve guideline. The 2025 European Society of Cardiology/European Association for Cardio-Thoracic Surgery (ESC/EACTS) guideline uses a single threshold: transfemoral TAVR is recommended at 70 years or older with a trileaflet valve and suitable anatomy (Class 1, A), and SAVR below 70 years at low surgical risk.

The age bands are surrogates for life expectancy set against known valve durability, and comorbidity, frailty, and patient values move individual patients across them. The European threshold of 70 years reflects randomized data in which most low-risk trial patients were in their 70s with trileaflet valves. NOTION-2 (low-risk patients aged 75 years or younger, mean age 71.1 years) and DEDICATE (mean age 74 years), discussed under lifetime management, also enrolled patients mostly in their 70s. The randomized trials of TAVR against surgery by risk stratum (PARTNER 1 through PARTNER 3, CoreValve High Risk, SURTAVI, and Evolut Low Risk) are tabulated in the randomized trials of TAVR versus surgery section. Trials of early TAVR in asymptomatic severe stenosis (EARLY TAVR) and of TAVR in moderate stenosis with reduced ejection fraction (TAVR UNLOAD) are covered under early intervention trials.

Medicare coverage for asymptomatic severe stenosis is narrower than the SAPIEN 3 approval. Under the 2026 national coverage determination, TAVR for asymptomatic severe aortic stenosis is covered only under coverage with evidence development (see US coverage).

The TAVR evaluation pathway from referral to procedure

The 2017 ACC Expert Consensus Decision Pathway for TAVR organizes the work-up as a sequence that begins with confirmation of severe symptomatic aortic stenosis and ends with a shared decision and a procedural plan (Otto 2017). The heart team includes at least an interventional cardiologist and a cardiac surgeon, with imaging specialists, anesthesiologists, the valve program coordinator, and, as needed, geriatric, palliative care, and other consultants. The evaluation answers four questions: whether the valve explains the symptoms, whether the patient will benefit, which procedure carries less risk for this anatomy, and what the patient values.

DomainComponentsQuestion answered
Severity and symptomsTransthoracic echocardiography with confirmation of stage; dobutamine echocardiography or CT calcium score when grading is discordant; exercise testing when symptoms are uncertainIs the stenosis severe and responsible for symptoms?
Surgical and procedural riskSTS PROM; frailty (gait speed, grip strength, activities of daily living); cognition; nutrition; major organ compromise; procedure-specific impedimentsWhich procedure is safer, and is either futile?
AnatomyECG-gated CT of the root with run-off to the femoral arteries; annular size and shape, calcium, coronary heights, sinus and sinotubular junction dimensions, membranous septal length, access vesselsIs transfemoral TAVR feasible, with which valve and which risks?
Coronary diseaseCoronary CT angiography in the planning scan when pretest probability is low; invasive angiography otherwiseIs revascularization indicated before or with valve replacement?
Conduction systemBaseline ECG for right bundle branch block, first-degree atrioventricular block, and bradycardia; ambulatory monitoring when symptoms suggest arrhythmiaWhat is the pacemaker risk, and does it change valve choice or implant depth?
ComorbidityKidney function, lung disease, liver disease, cancer, bleeding history, anemia, dental infection, other valve disease, cardiac amyloidosis when suspectedWill comorbidity limit benefit or change the procedure?
Goals and expectationsExpected symptom relief, recovery, durability, need for future procedures, end-of-life preferencesWhich strategy fits what the patient wants?

Domains of the heart team evaluation before TAVR, after the 2017 ACC Expert Consensus Decision Pathway and the 2020 ACC/AHA guideline.

The STS PROM categories (low below 3%, intermediate 3% to 8%, high above 8%, and prohibitive) and their frailty and organ system modifiers are defined under STS risk categories and the TAVR trials. Frailty, cognition, and nutrition as predictors of futility are measured as described in frailty before structural intervention. Program structure (Primary and Comprehensive Valve Centers) is described under valve center levels. Transfemoral TAVR is performed at both levels. Transcatheter valve-in-valve replacement for severely symptomatic bioprosthetic aortic stenosis at high or prohibitive surgical risk is reasonable (Class 2a) and is a Comprehensive Valve Center procedure.

Risk prediction for TAVR: the TVT in-hospital mortality model and futility

Surgical risk models predict death after SAVR. They were derived in surgical populations and do not include the access route; their limitations are discussed under STS PROM and EuroSCORE II. The first model derived in a TAVR population came from the STS/ACC TVT Registry. In it, 13,718 consecutive US patients treated from November 2011 to February 2014 (mean age 82.1 years) formed the development sample, and 6,868 patients treated later in 2014 formed the validation sample. In-hospital mortality was 5.3% (Edwards 2016). The model is the basis of the ACC TAVR in-hospital mortality risk calculator.

Predictor in the TVT in-hospital mortality modelOdds ratio (95% CI)
Age1.13 (1.06–1.20)
Glomerular filtration rate, per 5-unit increment0.93 (0.91–0.95)
Hemodialysis3.25 (2.42–4.37)
New York Heart Association (NYHA) class IV1.25 (1.03–1.52)
Severe chronic lung disease1.67 (1.35–2.05)
Nonfemoral access1.96 (1.65–2.33)
Procedural acuity category 21.57 (1.20–2.05)
Procedural acuity category 32.70 (2.05–3.55)
Procedural acuity category 43.34 (1.59–7.02)

Covariates of the STS/ACC TVT Registry model for in-hospital mortality after TAVR (Edwards 2016). C statistic 0.67 in development and 0.66 in validation; calibration did not differ significantly from ideal.

The model discriminates modestly (C statistic 0.66 to 0.67), which is typical of procedural mortality models in elderly populations with low event rates. Its uses are counseling, comparison of observed with expected mortality for program quality, and national monitoring. Because it predicts TAVR risk only, it has no role in the choice between SAVR and TAVR. Apart from procedural acuity, hemodialysis (odds ratio 3.25) and nonfemoral access (1.96) carry the highest odds ratios, consistent with the registry data on TAVR in dialysis.

Futility and poor outcome. Death is an incomplete outcome in this population, because survival without improvement in symptoms or function is not a benefit. In the PARTNER trial and its continued access registry (2,137 patients at high or prohibitive risk), 33% had a poor 6-month outcome, defined as death, a Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS) below 45, or a decrease of 10 points or more. A model built from baseline characteristics identified 10% of patients with a 50% or greater likelihood of a poor outcome, with moderate discrimination (C index 0.66 in development and 0.64 in validation) (Arnold 2014). The 2020 ACC/AHA guideline states that TAVR is not recommended when life expectancy is less than 1 year even with a successful procedure, or when the chance of survival with benefit at 2 years is less than 25%. The usual causes of futility are severe frailty unlikely to improve; advanced dementia; severe lung, liver, or kidney disease; and multiorgan compromise. Palliative management is described under severe aortic stenosis and futility of TAVR.

Planning CT and its effect on device and access choice

Contrast-enhanced, ECG-gated CT of the aortic root with a run-off acquisition of the aorta, iliac, and femoral arteries is the standard planning study (Blanke 2019). The root is acquired with retrospective gating or a wide systolic window, because the annulus is largest in early to mid systole and systolic measurements are preferred for sizing. The run-off of the aorta and iliofemoral arteries is acquired without gating. Protocol design is covered under CT protocol design by clinical question, and the measurement sequence (annular plane, area and perimeter, coronary heights, sinus and sinotubular junction, membranous septum) under CT planning for TAVR. The TAVR annulus and oversizing calculator applies the measurements to device sizing.

Planning CT findings shape valve choice, implant depth, and access. Annular area and perimeter select the valve size from the manufacturer's tables, and an annulus at the edge of two sizes, or one larger or smaller than any valve, may favor a particular platform or surgery. Bulky subannular or outflow tract calcium is managed with less oversizing or a self-expanding valve, because balloon-expandable oversizing in that setting is the main anatomic predictor of annular rupture. A low coronary ostium with a narrow sinus and a long, bulky leaflet raises the question of coronary protection or leaflet laceration (see coronary obstruction). A short membranous septum or baseline right bundle branch block moves the target implant depth higher. Minimal luminal diameter, calcium, and tortuosity of the iliofemoral arteries decide between transfemoral and alternative access (see access routes). In patients with a low pretest probability of coronary disease, coronary CT angiography in the same acquisition is an accepted alternative to invasive angiography, as described under CT for TAVR planning.

Coronary artery disease and PCI before TAVR

Coronary disease is common in TAVR candidates. The indications for coronary angiography before valve replacement are covered under invasive hemodynamics and coronary assessment. Before transcatheter replacement, percutaneous revascularization of significant left main or proximal disease is reasonable in the 2020 ACC/AHA guideline (Class 2a). In complex multivessel or left main disease with a SYNTAX score above 33, SAVR with coronary artery bypass grafting is reasonable and preferred over TAVR with percutaneous coronary intervention (PCI).

TrialPopulation and comparisonPrincipal result
ACTIVATION (2021)235 patients with severe aortic stenosis, significant coronary disease, and Canadian Cardiovascular Society class 2 or lower angina; PCI versus no PCI before TAVRDeath or rehospitalization at 1 year 41.5% versus 44.0%; noninferiority not met; more bleeding with PCI; mortality 13.4% versus 12.1%
NOTION-3 (2024)455 patients (median age 82 years) with at least one stenosis with fractional flow reserve 0.80 or less or diameter stenosis 90% or more; PCI versus conservative treatment, all undergoing TAVRDeath, myocardial infarction, or urgent revascularization over a median of 2 years 26% versus 36% (hazard ratio 0.71); bleeding 28% versus 20% (hazard ratio 1.51); PCI complications in 3%

Randomized trials of PCI in patients undergoing TAVR. Rates are PCI versus no PCI.

The two trials define the trade-off. Routine PCI of angiographic stenoses in patients with few anginal symptoms did not meet noninferiority in ACTIVATION and increased bleeding (Patterson 2021). PCI of physiologically significant or very severe stenoses in NOTION-3 reduced the composite of death, myocardial infarction, and urgent revascularization, with more bleeding (Lønborg 2024). PCI can be staged before TAVR, performed in the same procedure, or performed after TAVR; when it follows TAVR, the coronary ostia are engaged through the valve frame (see commissural alignment). Antiplatelet therapy after combined PCI and TAVR follows the coronary indication and is kept as short as the stent requires.

Transcatheter valve platforms and their design trade-offs

Transcatheter valves differ in how the frame expands, where the leaflets sit relative to the annulus, frame height, skirt design, and whether the valve can be recaptured. These features predict residual gradient, paravalvular regurgitation, conduction injury, coronary access, and the feasibility of a second transcatheter valve. The general taxonomy of prosthetic valves is under mechanical, bioprosthetic, and transcatheter valves, and their radiographic appearance under prosthetic valves and transcatheter devices on the chest radiograph.

FeatureBalloon-expandable, intra-annular (SAPIEN 3 family; Myval)Self-expanding, supra-annular (Evolut family)Self-expanding, intra-annular (Navitor)
Frame and deploymentCobalt-chromium frame expanded by balloon inflation under rapid ventricular pacing; position fixed once inflation beginsNitinol frame that expands as the capsule is withdrawn; recapturable and repositionable before releaseNitinol frame released gradually; recapturable before release
Leaflet positionWithin the annulusAbove the annulusWithin the annulus
Frame height and coronary accessShort frame below the coronary ostia in most anatomy; coronary re-engagement usually straightforwardTall frame extending into the ascending aorta; commissures and skirt can face the ostiaLarge frame cells; frame extends above the annulus
HemodynamicsHigher gradients and more mismatch in small annuliLower gradients and larger effective orifice area, especially in small annuliIntermediate
Paravalvular sealingOuter fabric skirt; radial force adapts poorly to bulky asymmetric calciumOuter pericardial wrap on current generationsActive outer fabric cuff
Conduction injuryLower pacemaker rates in most seriesHistorically higher; reduced by high implantation and cusp-overlap deploymentDepends on implant depth
Annular ruptureHigher risk with oversizing and subannular calciumLowLow

Design characteristics of contemporary transcatheter aortic valve platforms. Design and trial data are device specific, and sizing follows the current manufacturer tables for the generation in use. Myval was studied in the LANDMARK trial and offers sizes in 1.5-mm increments.

The choice of platform is made from the planning CT and the lifetime plan. A small annulus favors a supra-annular self-expanding valve for hemodynamics. Bulky outflow tract calcium, a horizontal aorta, or a low coronary ostium with need for later access calls for a design matched to the problem: limited oversizing for calcium, a valve that can be recaptured for difficult positioning, and a short frame with predictable commissures for future coronary access and redo TAVR. A balloon-expandable valve is often chosen for valve-in-valve and redo TAVR because its frame position is predictable, and a supra-annular self-expanding valve inside a small surgical valve yields a lower gradient.

Randomized comparisons of transcatheter valve platforms

Head-to-head trials have shown that platforms are not interchangeable and that the comparison depends on the end point chosen: clinical events, valve hemodynamics, or pacemaker implantation.

TrialPopulation and comparisonPrincipal result
SMART (2024)716 patients with annulus area 430 mm² or less (87% women, mean age 80 years); supra-annular self-expanding versus balloon-expandable valveDeath, disabling stroke, or heart failure rehospitalization at 12 months 9.4% versus 10.6% (noninferior); bioprosthetic valve dysfunction 9.4% versus 41.6%; mean gradient 7.7 versus 15.7 mm Hg; effective orifice area 1.99 versus 1.50 cm²; moderate or severe mismatch at 30 days 11.2% versus 35.3%
LANDMARK (2024)768 patients (mean age 80 years); Myval balloon-expandable valve versus SAPIEN or Evolut30-day Valve Academic Research Consortium 3 (VARC-3) composite 25% versus 27% (noninferior); no difference in individual components
ACURATE IDE (2025)1,500 patients at any surgical risk; ACURATE neo2 versus SAPIEN 3 or EvolutDeath, stroke, or rehospitalization at 1 year 14.8% versus 9.1% (hazard ratio 1.71); noninferiority not met; valve underexpansion associated with events

Randomized comparisons of transcatheter valve platforms. Rates are the first-named device versus comparator.

SMART established that, in small annuli, the supra-annular self-expanding valve gives better hemodynamics without worse 1-year clinical outcomes (Herrmann 2024). Whether the hemodynamic difference translates into fewer late clinical events remains open. Patient–prosthesis mismatch is defined and discussed on the prosthetic valve page. ACURATE IDE showed that a valve with acceptable registry results can perform worse in a randomized trial (Makkar 2025, Lancet). In a post hoc core laboratory analysis, 21.6% of implanted valves were underexpanded, a finding associated with heavier leaflet and annular calcium and with more death, stroke, or rehospitalization at 1 year (18.7% versus 11.8%) (Makkar 2025, J Am Coll Cardiol). LANDMARK showed noninferiority of a balloon-expandable valve with finer size increments at 30 days (Baumbach 2024).

Access routes for TAVR and their outcomes

Transfemoral access is the default route and was used in 95.3% of US procedures in 2019 (Carroll 2020). In the TVT mortality model, nonfemoral access nearly doubled the odds of in-hospital death (odds ratio 1.96), which reflects both the route and the vascular disease that prevents femoral access (Edwards 2016). The 2020 ACC/AHA age recommendations apply to transfemoral TAVR, and SAVR is recommended when valve or vascular anatomy is unsuitable for it (Class 1). Imaging of the access vessels, including the minimal luminal diameter required by the current sheath, is covered under access route assessment.

RouteTechniqueUse and limitations
TransfemoralPercutaneous common femoral puncture under ultrasound or fluoroscopic guidance; suture-based or plug-based closureDefault route; lowest morbidity; limited by small, calcified, or tortuous iliofemoral arteries and by aortic disease
Transaxillary or subclavianPercutaneous or surgical cutdown access, usually left sideMost frequently used alternative; contraindicated by small or diseased vessels and, on the left, by a patent left internal mammary artery graft
TranscarotidSurgical cutdown on the common carotid arteryShort, straight route; requires cerebrovascular assessment and adequate collateral flow
TranscavalElectrified wire crosses from the inferior vena cava to the abdominal aorta; the aortocaval tract is closed with a nitinol occluderFully percutaneous; requires a calcium-free aortic target and a suitable aortocaval relationship on CT
TransapicalLeft minithoracotomy and puncture of the left ventricular apexLargely abandoned; associated with higher mortality, delirium, and longer recovery
Direct transaorticUpper ministernotomy or right minithoracotomyLargely abandoned; requires a suitable ascending aorta

Access routes for TAVR. Choice depends on vessel size, calcium and tortuosity, sheath profile, previous surgery, and operator experience.

Transcaval access was tested in a prospective multicenter study of 100 patients ineligible for femoral artery access and at high risk for transthoracic access (STS PROM 9.6%). Access succeeded in 99 patients, inpatient survival was 96%, and 30-day survival was 92%. Life-threatening bleeding (7%) and major vascular complications possibly related to the access (13%) were frequent but acceptable for this population, and the median stay was 4 days (Greenbaum 2017). In the delirium meta-analysis below, the transapical approach carried an odds ratio of about 4 for delirium (Tilley 2018), one of the reasons transthoracic routes have been replaced by percutaneous alternatives where anatomy allows.

Conduct of the procedure: anesthesia, pacing, deployment, and implant depth

The minimalist approach. Most transfemoral procedures are performed with local anesthesia and conscious sedation, transthoracic echocardiographic guidance, percutaneous access and closure, and early mobilization. In SOLVE-TAVI, 447 patients undergoing transfemoral TAVR were randomized to conscious sedation or general anesthesia. The composite of death, stroke, myocardial infarction, infection requiring antibiotics, and acute kidney injury at 30 days was 27.2% versus 26.4%, meeting equivalence. Vasopressor or inotrope use was lower with conscious sedation (62.8% versus 97.3%) (Thiele 2020). General anesthesia with transesophageal echocardiographic (TEE) guidance remains in use for complex anatomy, valve-in-valve procedures, and patients who cannot lie still or protect the airway. The role of TEE during structural procedures is under guidance of structural heart interventions.

Sequence of a transfemoral procedure. Femoral access is obtained for the delivery sheath and contralateral femoral or radial access for a pigtail catheter in the noncoronary sinus. A temporary pacing lead is placed through a vein, or the stiff left ventricular guidewire is used as the pacing electrode. Heparin is given to a target activated clotting time. The valve is crossed with a straight wire, which is exchanged for a preshaped stiff wire curved in the left ventricular apex. Balloon predilation is performed when the valve is heavily calcified or the orifice is too small for the delivery system; many procedures with current balloon-expandable and some self-expanding systems proceed with direct implantation. The valve is positioned in a projection that aligns the cusps, deployed, and assessed by aortography, hemodynamics, and echocardiography. Postdilation is performed for underexpansion or paravalvular regurgitation, with caution in a heavily calcified annulus. Heparin is reversed with protamine and the access is closed.

Rapid ventricular pacing. Rapid pacing reduces stroke volume and transvalvular flow and stabilizes the balloon or the valve during balloon dilation, balloon-expandable deployment, and postdilation; with self-expanding systems, pacing is used selectively during positioning and release. The technique, including left ventricular guidewire pacing (EASY TAVI, 303 procedures), is detailed under temporary pacing during TAVR.

Fluoroscopic projections and implant depth. A coplanar (three-cusp) view aligns the three sinus nadirs in one plane. The cusp-overlap view superimposes the right and left coronary cusps and isolates the noncoronary cusp; it elongates the outflow tract, removes parallax from the delivery catheter, and shows implant depth at the noncoronary cusp, near the conduction axis. In a meta-analysis of 14 studies with 5,266 patients, centered on self-expanding valves, the cusp-overlap technique was associated with fewer pacemaker implantations (11.2% versus 17.7%) and a higher implant position (Hazique 2025). Membranous septum–guided implantation, which keeps the implant depth shorter than the membranous septal length, lowered new pacemaker implantation from 9.7% to 3.0% at one center (Jilaihawi 2019). Implant depth targets are device specific: a low valve presses on the conduction system and the anterior mitral leaflet, and a high valve risks embolization and paravalvular regurgitation. Intraprocedural imaging criteria for position and regurgitation are under intraprocedural imaging during TAVR.

Four fluoroscopic frames of transcatheter aortic valve deployment. Left column: three-cusp coplanar view with the noncoronary, right, and left coronary cusps marked separately. Right column: cusp-overlap view with the right and left coronary cusps superimposed and the noncoronary cusp isolated. Upper row shows a balloon-expandable valve and lower row a mechanically expanded valve.
Three-cusp coplanar (TCC, left) and cusp-overlap (COP, right) projections during deployment of a balloon-expandable valve (upper row) and a mechanically expanded valve (lower row). In the cusp-overlap view, the right (RCC) and left (LCC) coronary cusps superimpose and the noncoronary cusp (NCC) is isolated, so implant depth is read at the cusp closest to the membranous septum and the conduction axis. Credit: Stephan T, Krohn-Grimberghe M, von Lindeiner genannt von Wildau A, et al., Frontiers in Cardiovascular Medicine 2023;10:1269833, Figure 4, CC BY 4.0.

Commissural alignment and coronary access after TAVR

A transcatheter valve has three neo-commissures. When a commissural post or the leaflet-bearing part of the skirt lies in front of a coronary ostium, later coronary angiography, PCI, and a second transcatheter valve become harder, and leaflet modification at redo TAVR may fail to open the sinus. In ALIGN TAVR, CT and fluoroscopy of 828 patients were coregistered, and severe overlap was defined as a neo-commissural post 0° to 20° from a coronary artery. The crimped orientation of the balloon-expandable SAPIEN 3 valve did not influence final alignment. With the Evolut valve, severe overlap with the left main coronary artery occurred in 66.0% when the "hat" marker lay at the inner curve or center back at initial deployment and in 15.7% when it lay at the outer curve or center front. The corresponding rates of overlap with the right coronary artery were 51.1% and 7.1%. Tracking the "hat" marker at the outer curvature of the descending aorta increased outer-curve orientation at deployment from 70.2% to 91.6% and reduced coronary overlap by 36% to 60% (Tang 2020).

Alignment techniques are device specific: in ALIGN TAVR, the orientation of the self-expanding Evolut and ACURATE neo valves at deployment determined the final commissural position (Tang 2020). In younger patients, the plan includes CT prediction of the neo-commissure position relative to the coronary ostia.

Coronary re-access after TAVR is generally feasible but depends on the platform. In RE-ACCESS, 300 consecutive patients underwent angiography before and after TAVR; selective cannulation failed in 7.7%, and 22 of the 23 failures occurred with Evolut R or PRO valves (17.9% versus 0.4% with other valves). Independent predictors were the Evolut platform, a greater valve-to-sinus relation, and a shallower implant depth. A model combining them predicted failure with an area under the curve of 0.94 (Barbanti 2020). These data support documenting the valve type, size, and implant depth in the procedural report so that later angiographers can choose catheters. They also support a deliberate plan for coronary access in patients with coronary disease or a long life expectancy.

Coronary obstruction: risk, BASILICA, and chimney stenting

Acute coronary obstruction occurs when a displaced native or surgical leaflet covers a coronary ostium or seals the sinus at the sinotubular junction. In a multicenter registry of 6,688 TAVR procedures, symptomatic coronary obstruction occurred in 0.66%, mostly of the left coronary artery (88.6%), and was more frequent in women, with balloon-expandable valves, and in valve-in-valve procedures (Ribeiro 2013). It presents as hypotension, ST-segment change, ventricular arrhythmia, or cardiac arrest after deployment. CT predictors include coronary height, sinus width, leaflet length and bulk, the sinotubular junction, and the virtual transcatheter valve-to-coronary distance in valve-in-valve and native valves. These predictors are described under root anatomy and coronary obstruction risk and applied in the coronary obstruction risk tool.

When CT predicts high risk, the heart team chooses among four strategies: surgery, a different valve or implant position, coronary protection, or leaflet laceration.

Coronary protection and chimney stenting. A guidewire, and often an undeployed stent, is placed in the threatened coronary before valve deployment. If flow is compromised after deployment, the stent is pulled back and deployed from the coronary into the aorta alongside the transcatheter frame (chimney or snorkel stenting). In the international Chimney Registry, 60 chimney stenting procedures were performed among 12,800 TAVR procedures (0.5%), 25 for established and 35 for impending occlusion. Myocardial infarction (52.0% versus 0.0%), cardiogenic shock (52.0% versus 2.9%), and resuscitation (44.0% versus 2.9%) were more frequent with established than with impending occlusion. The absence of upfront coronary protection was the only independent predictor of death, shock, or myocardial infarction. Two stent failures occurred during a median follow-up of 612 days (Mercanti 2020). A chimney stent outside the frame can be compressed and makes later coronary access and redo TAVR harder.

BASILICA. Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) splits the leaflet in front of the threatened ostium before valve implantation. A guidewire is electrified, passed through the base of the leaflet, and snared in the aorta. The leaflet is then lacerated along its length so that it splays away from the ostium after the transcatheter valve opens it. In the prospective BASILICA trial of 30 patients, the primary success end point was met in 93%, with no coronary obstruction (Khan 2019). The technique requires an experienced center, adds stroke risk from leaflet manipulation, and is less effective when the commissure of the new valve faces the ostium or when the sinus is sequestered by a narrow sinotubular junction. Single-leaflet and double-leaflet laceration are both performed, and dedicated leaflet-splitting devices are under study.

Coronary obstruction risk from planning CT

In native valves, a coronary height below 10 mm and a mean sinus of Valsalva diameter below 30 mm are screening markers (Shatila 2017). In the multicenter registry, patients with obstruction had a mean left coronary height of 10.6 mm and a mean sinus diameter of 28.1 mm, compared with 13.4 and 31.9 mm in controls (Ribeiro 2013). In a native-valve study of 60 patients with obstruction and 1,381 without, coronary height and sinus width predicted obstruction poorly. A multivariate model predicted obstruction when the cusp leaflet height exceeded the coronary height and either the virtual transcatheter valve-to-coronary distance (VTC) was 4 mm or less or the culprit leaflet calcium volume was above 600 mm³. The area under the curve was 0.93 for the left and 0.94 for the right coronary artery (Khan 2023). Among 1,612 aortic valve-in-valve procedures in the VIVID registry, clinically evident obstruction occurred in 2.3%, and a VTC below 4 mm was the optimal cutoff (area under the curve 0.943; Ribeiro 2018). A VTC of 4 mm or less, a virtual transcatheter valve-to-sinotubular junction distance (VTSTJ) of 3 mm or less, or both were the CT criteria used to select dedicated mechanical leaflet splitting in 150 valve-in-valve procedures (Makkar 2026). For redo TAVR, high risk of sinus sequestration is defined as a distance from the index transcatheter valve to the sinotubular junction below 2 mm with the risk plane above the junction (Sato 2023; Koshy 2024).

Left coronary—
Right coronary—
Sinus of Valsalva—
—

Native valve: coronary height below 10 mm and mean sinus of Valsalva diameter below 30 mm (Shatila 2017; registry means from Ribeiro 2013). Native-valve model: cusp leaflet height above the coronary height, with a VTC of 4 mm or less or a culprit leaflet calcium volume above 600 mm³ (Khan 2023). Valve-in-valve in a surgical bioprosthesis: VTC below 4 mm (Ribeiro 2018); VTC of 4 mm or less or VTSTJ of 3 mm or less as criteria for leaflet modification (Makkar 2026). Redo TAVR: distance from the index valve to the sinotubular junction below 2 mm with the risk plane above the junction (Sato 2023; Koshy 2024). Coronary height is measured perpendicular to the annular plane to the lower edge of the ostium. With the default values, the left coronary height of 9.5 mm and the mean sinus diameter of 28 mm meet the native screening markers, and the right coronary height of 14 mm meets none. VTC, virtual transcatheter valve-to-coronary distance; VTSTJ, virtual transcatheter valve-to-sinotubular junction distance.

Complications of TAVR: incidence, prevention, and management

The VARC-3 document defines the end points used in trials and registries: death, stroke, bleeding, vascular and access complications, acute kidney injury, conduction disturbance, myocardial injury, valve dysfunction, and composite measures of technical success, device success, and early safety (Généreux 2021). The comparison with surgical complications is summarized under procedural complications of TAVR and SAVR, and the imaging signatures of acute complications under complications of TAVR recognized by imaging.

ComplicationRepresentative incidenceMain risk factorsPreventionManagement
New permanent pacemaker10.8% (US registry, 2019); 17.4% versus 6.1% with SAVR in Evolut Low RiskRight bundle branch block, deep implantation, short membranous septum, oversizing, self-expanding valveHigh implantation, cusp-overlap view, membranous septum–guided depthMonitoring pathway; pacing for persistent high-grade block
Stroke2.3% at 30 days (US registry, 2019); about 2% within 72 hoursCalcified valve and aorta, valve manipulation, postdilation, new atrial fibrillationMinimal manipulation; antithrombotic therapy; embolic protection has not reduced stroke in trialsStroke team activation, thrombectomy for large vessel occlusion
Moderate or severe aortic regurgitation3.5% versus 0.5% with SAVR in Evolut Low Risk; 3.8% above mild in 3M TAVRUndersizing, asymmetric calcium, malposition, bicuspid anatomyCT sizing, appropriate oversizing, correct depthPostdilation, second valve, later plug closure
Major vascular complication2.4% in 3M TAVR; 13% possibly access related with transcaval accessSmall, calcified iliofemoral arteries, large sheath, female sex, closure failureCT access planning, ultrasound-guided punctureBalloon tamponade, covered stent, surgical repair
Valve embolization or migration0.92% (TRAVEL registry)Undersizing, high or low implantation, self-expanding or early-generation valve, bicuspid valveCorrect sizing, stable pacing, recapture before releaseRepositioning, second valve, surgery
Coronary obstruction0.66%Low ostium, narrow sinus, bulky leaflet, valve-in-valve, female sexCT prediction, protection, BASILICAChimney stenting, PCI, surgery
Annular or root ruptureRareBulky subannular calcium, balloon-expandable oversizing, postdilationLimited oversizing in calcified outflow tracts; platform choicePericardial drainage, reversal of anticoagulation, surgery or conservative care by type
Acute kidney injury0.9% versus 2.8% with SAVR in Evolut Low Risk; 9.0% in SOLVE-TAVIChronic kidney disease, contrast, hypotension, bleedingContrast minimization, hemodynamic stabilitySupportive care
DeliriumAbout 23% when assessed systematicallyAcute kidney injury, transapical access, carotid disease, cognitive impairmentConscious sedation, transfemoral access, early mobilizationNonpharmacologic delirium care

Complications of TAVR. Incidence varies with patient risk, platform, era, and definition; figures are from the sources discussed in the text (Carroll 2020; Popma 2019; Wood 2019; Greenbaum 2017; Kim 2019; Ribeiro 2013; Thiele 2020; Tilley 2018).

Stroke and cerebral embolic protection

Most strokes after TAVR are embolic and occur during or soon after the procedure, from calcium, atheroma, thrombus, or tissue dislodged during wire and catheter manipulation, balloon dilation, and valve deployment. Stroke occurs in about 2% of patients within 72 hours of TAVR, and later strokes relate to atrial fibrillation, leaflet thrombosis, and the patient's vascular disease. In a pooled analysis of 25 prospective studies with 1,225 patients, diffusion-weighted MRI showed new, mostly clinically silent ischemic lesions in 77.5% of patients after TAVR (Pagnesi 2016). Their long-term cognitive effect is uncertain. Periprocedural stroke after other cardiac procedures is compared in the periprocedural stroke section of the cardioembolic stroke page.

TrialPopulation and devicePrincipal result
PROTECTED TAVR (2022)3,000 patients undergoing transfemoral TAVR in North America, Europe, and Australia; dual-filter device versus no protectionStroke within 72 hours or before discharge 2.3% versus 2.9% (difference −0.6 percentage points; 95% CI −1.7 to 0.5); disabling stroke 0.5% versus 1.3%; device deployed in 94.4% of attempts
BHF PROTECT-TAVI (2025)7,635 patients in the United Kingdom; routine filter protection versus noneStroke within 72 hours or before discharge 2.1% versus 2.2%

Randomized trials of cerebral embolic protection during TAVR. Rates are protection versus no protection.

Neither trial showed a reduction in the primary end point of stroke (Kapadia 2022; Kharbanda 2025). PROTECTED TAVR found fewer disabling strokes with the device as a secondary end point, which prompted the larger BHF PROTECT-TAVI trial. Routine embolic protection is therefore not supported by randomized evidence, and selective use in patients with a high expected embolic burden rests on clinical judgment. A filter device requires right radial or brachial access, and the brachiocephalic and left common carotid filters do not protect the left vertebral artery territory.

Stroke after TAVR is managed by the stroke team, and mechanical thrombectomy is the reperfusion option for a large vessel occlusion after a cardiac procedure. Postprocedural atrial fibrillation is anticoagulated according to its own indication.

Conduction disturbance and pacemaker implantation

The transcatheter frame seats against the interventricular septum over the His bundle and the origin of the left bundle. New left bundle branch block and high-grade atrioventricular block are the resulting electrical complications. In a meta-analysis of 41 studies with 11,210 patients, 17% received a pacemaker, with preexisting right bundle branch block the strongest electrocardiographic predictor (Siontis 2014). Pacemaker rates are lower with balloon-expandable valves, high implantation, cusp-overlap deployment, and membranous septum–guided depth, as described in the procedure section. Mechanism, predictors, prognosis, and the full pathway are on the conduction disturbances after TAVR page, and pacing indications for block after TAVR are under conduction disease after TAVR.

The 2020 ACC Expert Consensus Decision Pathway classifies patients by the ECG before and after the procedure (Lilly 2020). Patients without a new conduction disturbance have the temporary pacing lead removed in the procedure room and are eligible for early discharge. New left bundle branch block, PR or QRS prolongation of 20 ms or more, or transient complete heart block leads to a secure temporary lead and telemetry until conduction is stable for 48 hours or more. When such a patient is discharged without a pacemaker, an ambulatory monitor is worn for at least 14 days. Persistent complete heart block requires a permanent device, and new or progressive conduction disease in a patient with preexisting conduction disease leads the heart team to consider an electrophysiology study or permanent pacing. In the MARE study, 103 patients with new persistent left bundle branch block after TAVR received an implantable cardiac monitor; over 12 months, 21 had high-degree atrioventricular block or severe bradycardia, and 11 (11%) received a pacemaker or defibrillator, mostly after silent events (Rodés-Cabau 2018).

Conduction system pacing after TAVR. When a pacemaker is required, His bundle or left bundle branch area pacing avoids the dyssynchrony of right ventricular pacing, which matters in patients with long life expectancy and a high expected pacing burden. The frame and the septal injury that caused the block can make the conduction system harder to capture. The 2023 Heart Rhythm Society, Asia Pacific Heart Rhythm Society, and Latin American Heart Rhythm Society (HRS/APHRS/LAHRS) physiologic pacing guideline did not find sufficient data to recommend a device type after TAVR. Capture criteria and technique are under guideline recommendations for conduction system pacing.

Paravalvular regurgitation

Paravalvular regurgitation results from incomplete apposition of the frame to the annulus: undersizing, bulky or asymmetric calcium, an elliptical annulus, a bicuspid valve, or an implant that is too high or too low. Moderate or greater paravalvular regurgitation after TAVR is associated with higher late mortality, and in the early PARTNER experience even mild regurgitation carried prognostic weight. Current valves with outer skirts and CT-based sizing have reduced its frequency. In Evolut Low Risk, moderate or severe aortic regurgitation at 30 days occurred in 3.5% after self-expanding TAVR and 0.5% after SAVR (Popma 2019). In RHEIA, moderate or greater paravalvular regurgitation was below 1% in both groups.

Prevention begins with sizing from the CT annular area and perimeter, oversizing within the device-specific range, and a target depth that places the skirt across the annulus. During the procedure, regurgitation is graded by echocardiography, aortography, and hemodynamics (the diastolic gradient between aorta and left ventricle). Moderate or greater regurgitation is treated by balloon postdilation for underexpansion or a second valve for malposition during the same procedure, or later by percutaneous plug closure. Grading criteria (circumferential extent, vena contracta) and closure are on the paravalvular regurgitation page.

Vascular complications and bleeding

Vascular injury at the large-bore access site (dissection, perforation, occlusion, pseudoaneurysm, and closure device failure) is the main source of major bleeding after transfemoral TAVR. Risk rises with small, calcified, or tortuous iliofemoral arteries, a sheath large relative to the vessel, high or low puncture, and female sex. Ultrasound-guided puncture of the common femoral artery above its bifurcation and below the inguinal ligament, CT-based sheath selection, and preclosure with suture devices or plug-based closure reduce the risk. Bleeding and vascular complications are treated with balloon tamponade from the contralateral side, covered stents, or surgical repair. In the low-risk trials, bleeding complications were less frequent after TAVR than after SAVR (2.4% versus 7.5% at 30 days in Evolut Low Risk) (Popma 2019). In women, smaller vessels and small annuli are associated with more vascular complications and higher gradients, as discussed under valve disease in women.

Annular rupture, ventricular perforation, and tamponade

Annular rupture is a rare injury to the aortic root or outflow tract during balloon dilation, balloon-expandable deployment, or postdilation. Its presentation ranges from contained periaortic hematoma to free rupture with tamponade and death. Bulky subannular or outflow tract calcium and area oversizing of 20% or more with a balloon-expandable valve are the main anatomic predictors. Contained ruptures can be managed conservatively with reversal of anticoagulation, and free rupture requires pericardial drainage and emergency surgery.

Tamponade during TAVR also results from perforation of the left ventricle by the stiff guidewire, particularly in a small, hypertrophied ventricle, or of the right ventricle by a temporary pacing lead. A new effusion with right ventricular collapse is drained percutaneously, heparin is reversed, and persistent bleeding from the left ventricle requires surgical repair. Pericardiocentesis technique is under pericardial effusion and tamponade.

Valve embolization and malposition

In the TRAVEL registry, periprocedural valve embolization or migration occurred in 273 of 29,636 TAVR procedures (0.92%), 217 into the ascending aorta and 56 into the left ventricle. Self-expanding or first-generation prostheses and a bicuspid valve were independent predictors. Bailout included repositioning with snares or other tools (41.0%), implantation of additional valves (83.2%), and conversion to surgery (19.0%). In a propensity-matched comparison, embolization or migration was associated with higher 30-day mortality (18.6% versus 4.9%) and 1-year mortality (30.5% versus 16.6%) and more major stroke at 30 days (10.6% versus 2.8%) (Kim 2019).

Acute kidney injury, delirium, and cognitive outcomes

Acute kidney injury after TAVR results from contrast, hypotension during rapid pacing, embolism of atheroma, and bleeding, on a background of chronic kidney disease. It is less frequent after TAVR than after surgery: 0.9% versus 2.8% at 30 days in Evolut Low Risk (Popma 2019). In SOLVE-TAVI, the incidence was 9.0% with conscious sedation and 9.2% with general anesthesia (Thiele 2020). Contrast is limited by using the planning CT for sizing and projection angles, hemodynamics are kept stable, and nephrotoxic drugs are held.

In a meta-analysis of studies in patients 60 years and older, delirium after TAVR occurred in 23% overall and in 24.9% in studies that assessed it for at least 3 consecutive days. Acute kidney injury (odds ratio 5), transapical access (odds ratio 4), and carotid disease (odds ratio 4) were the strongest risk factors (Tilley 2018). Delirium is a preventable contributor to later cognitive impairment, and its prevention relies on transfemoral access, conscious sedation, early mobilization, orientation, and avoidance of deliriogenic drugs. Formal cognitive testing before TAVR also informs the futility assessment.

Mitral and tricuspid regurgitation after TAVR

Functional mitral regurgitation caused by pressure overload, a dilated ventricle, or atrial fibrillation often improves after the afterload of aortic stenosis is relieved, whereas primary mitral disease and mitral regurgitation from annular calcification do not. Significant tricuspid regurgitation and pulmonary hypertension before TAVR identify advanced disease with a worse prognosis. When severe mitral or tricuspid regurgitation persists after TAVR and causes symptoms, staged transcatheter edge-to-edge repair is an option. Mixed and multivalve disease is covered under aortic stenosis with mixed and multivalve disease. A valve implanted low can also injure the anterior mitral leaflet or entrap chordae with the guidewire, which appears as new mitral regurgitation after deployment.

Care after TAVR: discharge, monitoring, drugs, and echocardiography

Discharge. After uncomplicated transfemoral TAVR, most patients are discharged the next day. The Vancouver 3M pathway combines objective screening, conscious sedation, percutaneous access, early mobilization, and defined discharge criteria. In the 3M TAVR study of 411 patients at 13 centers (median age 84 years), 80.1% went home the next day and 89.5% within 48 hours. Death or stroke at 30 days occurred in 2.9%, readmission in 9.2%, and new pacemaker in 5.7%, independent of center volume (Wood 2019). Compared with matched patients from a contemporaneous trial, the minimalist pathway lowered cumulative 30-day hospital and follow-up expenditure by $11,305 per patient with similar clinical outcomes (Butala 2022). Discharge is deferred when the ECG shows a new or progressive conduction disturbance that requires monitoring under the conduction pathway.

ElementContentRelated section
ECG and rhythm monitoringECG after the procedure and before discharge; telemetry and ambulatory monitoring by conduction riskConduction pathway
Antithrombotic therapyAspirin 75–100 mg daily without another anticoagulation indication (Class 2a); oral anticoagulation alone when indicatedAntithrombotic table
Baseline echocardiogram1 to 3 months after implantation, then annuallySurveillance after valve replacement
Endocarditis preventionAntibiotic prophylaxis before dental procedures that manipulate gingival tissue or the periapical region is reasonable for prosthetic valves, transcatheter valves included (Class 2a); dental hygieneTranscatheter valve endocarditis
Heart failure therapyGuideline-directed therapy for reduced ejection fraction; dapagliflozin in patients with prior heart failure and kidney disease, diabetes, or systolic dysfunctionDapagliflozin after TAVR, below
RehabilitationReferral to cardiac rehabilitationRehabilitation after TAVR
Valve cardValve type, size, implant depth, and coronary access notes recorded for the patient and later operatorsCoronary access

Care after TAVR, after the 2020 ACC/AHA guideline and the 2017 ACC Expert Consensus Decision Pathway.

Antithrombotic therapy. After TAVR, aspirin 75 to 100 mg daily is reasonable in the absence of another indication for oral anticoagulation (Class 2a). In POPular TAVI cohort A, aspirin alone reduced bleeding at 1 year compared with aspirin plus clopidogrel (15.1% versus 26.6%) without more thromboembolic events (Brouwer 2020). Low-dose rivaroxaban with aspirin increased death, thromboembolism, and bleeding in GALILEO and is harmful in patients without another indication for anticoagulation (Class 3: Harm) (Dangas 2020). Patients with atrial fibrillation continue oral anticoagulation, generally without added antiplatelet therapy. The full table of classes and trials is under antithrombotic therapy after bioprosthetic valves and TAVR, and combined anticoagulant and antiplatelet regimens under other anticoagulation indications.

Dapagliflozin after TAVR. DapaTAVI randomized 1,257 patients with a history of heart failure plus kidney dysfunction, diabetes, or left ventricular systolic dysfunction to dapagliflozin 10 mg daily or standard care after TAVR, with 1,222 included in the primary analysis. Death or worsening heart failure at 1 year occurred in 15.0% versus 20.1% (hazard ratio 0.72); worsening heart failure was less frequent (9.4% versus 14.4%), and death from any cause did not differ significantly (7.8% versus 8.9%). Genital infection and hypotension were more common with dapagliflozin (Raposeiras-Roubin 2025).

Echocardiographic follow-up. The baseline transthoracic study 1 to 3 months after implantation, at stable loading conditions, records the mean gradient, effective orifice area, Doppler velocity index, paravalvular and central regurgitation, and ventricular function. It is the reference for later studies, which are performed annually and whenever symptoms, a new murmur, or embolism occur. A rise in mean gradient prompts evaluation for leaflet thrombosis before it is attributed to structural deterioration. Doppler criteria are under Doppler assessment of prosthetic aortic valves, and the imaging schedule after structural procedures under follow-up imaging.

Endocarditis. In an international registry of 20,006 patients after TAVR, endocarditis occurred at 1.1% per person-year, with a median onset 5.3 months after implantation, and in-hospital mortality was 36% (Regueiro 2016). Enterococci and Staphylococcus aureus predominate, the frame impairs echocardiographic detection, and CT and fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT are often required, as discussed under prosthetic and transcatheter valve endocarditis.

Valve hemodynamics, mismatch, and leaflet thrombosis after TAVR

Transcatheter valves have larger effective orifice areas and lower gradients than surgical valves of the same size, because the frame displaces the native leaflets and has no sewing ring. In Evolut Low Risk, the 12-month mean gradient was 8.6 mm Hg after TAVR and 11.2 mm Hg after SAVR, and the effective orifice area 2.3 versus 2.0 cm² (Popma 2019). Supra-annular valves have lower gradients than intra-annular valves, most clearly in small annuli (SMART). VARC-3 defines patient–prosthesis mismatch by the indexed effective orifice area: moderate at 0.85 cm²/m² or less and severe at 0.65 cm²/m² or less, with lower thresholds when the body mass index is 30 kg/m² or more. Mismatch is discussed under patient–prosthesis mismatch.

Subclinical leaflet thrombosis. Hypoattenuated leaflet thickening (HALT) and reduced leaflet motion on contrast CT are more frequent after TAVR than after surgical bioprosthetic replacement and in patients not receiving anticoagulation. Most cases are asymptomatic, some resolve spontaneously, and anticoagulation reduces the finding without improving clinical outcomes in patients who lack another indication (GALILEO, ATLANTIS). CT is reserved for a rising gradient or embolism. Clinically significant valve thrombosis is treated with a vitamin K antagonist (Class 2a). Definitions, images, and trials are on the subclinical leaflet thrombosis page.

Patient–prosthesis mismatch calculator for TAVR

The calculator indexes the effective orifice area (EOA) to body surface area and grades patient–prosthesis mismatch by the VARC-3 thresholds (Généreux 2021). Before implantation, the expected EOA for the planned valve type and size predicts mismatch; after implantation, the EOA measured by the continuity equation on the baseline echocardiogram confirms it. In SMART, moderate or severe mismatch at 30 days occurred in 11.2% of patients with a supra-annular self-expanding valve and 35.3% with a balloon-expandable valve in annuli of 430 mm² or less (Herrmann 2024).

Body surface area (Mosteller)—
Body mass index—
Indexed EOA—
VARC-3 mismatch grade—
EOA that avoids moderate mismatch—
—

Body surface area (Mosteller) = √(height in cm × weight in kg ÷ 3,600). Body mass index = weight in kg ÷ (height in m)². Indexed EOA = EOA ÷ body surface area. VARC-3 aortic thresholds: with a body mass index below 30 kg/m², moderate mismatch is 0.85 cm²/m² or less and severe mismatch 0.65 cm²/m² or less; with a body mass index of 30 kg/m² or more, moderate mismatch is 0.70 cm²/m² or less and severe mismatch 0.55 cm²/m² or less. The EOA that avoids moderate mismatch = moderate threshold × body surface area. With the default values, body surface area is 1.82 m², body mass index 26.4 kg/m², and indexed EOA 0.83 cm²/m² (moderate mismatch); an EOA above 1.54 cm² avoids moderate mismatch. EOA, effective orifice area; VARC-3, Valve Academic Research Consortium 3.

Durability of transcatheter valves

Durability is described with VARC-3 terms. Hemodynamic structural valve deterioration is graded by the rise in mean gradient with a fall in effective orifice area and Doppler velocity index, or by new intraprosthetic regurgitation, compared with the baseline study. Bioprosthetic valve failure is death, reintervention, or severe hemodynamic deterioration attributable to the valve. Nonstructural dysfunction (mismatch, paravalvular regurgitation), thrombosis, and endocarditis are separate categories (Généreux 2021). Stages and Doppler criteria are under structural valve deterioration.

TrialPopulationLong-term result (TAVR versus SAVR)
NOTION (10-year, 2024)280 patients aged 70 years or older at low risk; self-expanding valveDeath, stroke, or myocardial infarction 65.5% in both arms; severe structural deterioration 1.5% versus 10.0%; bioprosthetic valve failure 9.7% versus 13.8% (not significant); permanent pacemaker 44.7% versus 14.0%
PARTNER 3 (5-year, 2023)1,000 low-risk patients, mean age about 73 years; balloon-expandable valveDeath, stroke, or rehospitalization 22.8% versus 27.2% (not significant); bioprosthetic valve failure 3.3% versus 3.8%
PARTNER 3 (7-year, 2026)Same cohortDeath, stroke, or rehospitalization 34.6% versus 37.2%; death 19.5% versus 16.8%; stroke 8.5% versus 8.1%; mean gradient 13.1 versus 12.1 mm Hg; bioprosthetic valve failure 6.9% versus 7.5%
Evolut Low Risk (5-year, 2025)1,414 low-risk patients; self-expanding valveDeath or disabling stroke 15.5% versus 16.4% (not significant); reintervention 3.3% versus 2.5%

Long-term randomized durability data for TAVR compared with SAVR (Thyregod 2024; Mack 2023; Leon 2026; Forrest 2025).

Through 7 to 10 years, transcatheter valves have not shown more structural deterioration or failure than surgical bioprostheses in the randomized trials (Leon 2026; Thyregod 2024). Two qualifications apply. Trial patients were mostly in their 70s, so data in patients younger than 65 years, who may outlive two valves, are limited. In older cohorts, late death is a competing risk that lowers the apparent incidence of valve failure. Durability is therefore a planning variable in younger patients and a minor consideration in octogenarians.

Failed transcatheter valves: redo TAVR and surgical explantation

A failed transcatheter valve is treated with a second transcatheter valve inside it (redo TAVR, or TAV-in-TAV) or with surgical explantation and replacement. Failed surgical bioprostheses are a separate problem, treated with redo surgery or transcatheter valve-in-valve implantation (Class 2a at high or prohibitive surgical risk) as described under failed bioprostheses.

Data sourcePopulationPrincipal result
STS/ACC TVT Registry, redo TAVR with balloon-expandable valves (2023)1,320 redo procedures among 350,591 TAVR procedures, propensity-matched to native TAVR; mean predicted surgical mortality 8.1%Death at 30 days 4.7% versus 4.0% and at 1 year 17.5% versus 19.0%; stroke at 30 days 2.0% versus 1.9%; coronary compression or obstruction 0.3%; mean gradient at 1 year 15 versus 12 mm Hg
EXPLANT-TAVR registry (2021)269 surgical explantations at 42 centers; median 11.5 months after TAVRIndications: endocarditis 43.1%, structural deterioration 20.1%, paravalvular leak 18.2%, mismatch 10.8%; redo TAVR not feasible anatomically in 26.8%; mortality 11.9% in hospital, 13.1% at 30 days, 28.5% at 1 year
FRANCE 2 and FRANCE TAVI registries (2025)72,850 TAVR patients, 2010–2022; reintervention for endocarditis excludedCumulative reintervention 1.7% at 8 years (591 redo TAVR, 111 explantations), most within the first year; predictors included a mean gradient above 20 mm Hg after TAVR, aortic regurgitation grade 2 or more, and PCI after TAVR

Outcomes of reintervention after TAVR (Makkar 2023; Bapat 2021; Durand 2025). Rates in the first row are redo TAVR versus matched native TAVR.

Redo TAVR with balloon-expandable valves treated failed transcatheter valves with low complication rates, and its death and stroke rates were similar to those of matched native procedures, independent of the timing of the redo procedure and the type of index valve (Makkar 2023). Surgical explantation carries substantial risk. In EXPLANT-TAVR, it was urgent or emergent in 53.1% of patients and included aortic root replacement in 13.4% and concomitant cardiac procedures in 54.6%. Endocarditis, for which redo TAVR is not an option, was the most frequent indication (Bapat 2021).

Planning the second valve. The main hazard of redo TAVR is sinus sequestration: the second valve pins the leaflets of the first valve open into a cylinder that reaches the sinotubular junction and seals the aortic sinus (sinus of Valsalva), cutting off flow to the coronary ostium. CT simulation of the second valve estimates the distance from the leaflet cylinder to the sinotubular junction and to the coronary ostia, using the frame height, the level of the leaflet commissures, and the sinus dimensions. Risk is greatest with a tall supra-annular frame implanted high, a narrow or low sinotubular junction, and commissures aligned with the ostia. Leaflet laceration of a transcatheter valve (redo BASILICA) and coronary protection are the transcatheter options, and their success depends on commissural alignment of the first valve.

Lifetime management in younger patients

A patient treated at 65 years may need two or three aortic valve procedures in a lifetime, so the first procedure is chosen for what it leaves possible. The sequence SAVR first, then transcatheter valve-in-valve, depends on a surgical valve large enough to accept a transcatheter valve without high gradients. Small surgical valves and mismatch are therefore avoided at the first operation, or a valve suitable for ring fracture is chosen. The sequence TAVR first, then redo TAVR, depends on a first valve whose frame, commissural position, and implant height leave the coronary ostia accessible and the aortic sinuses open. Choice of prosthesis type by age is covered under choice of prosthesis.

Two randomized trials extend the low-risk evidence: NOTION-2 to patients aged 75 years or younger and DEDICATE to routine practice. NOTION-2 randomized 370 low-risk patients (mean age 71.1 years; 100 with bicuspid stenosis) to TAVR or SAVR. The 1-year composite of death, stroke, or rehospitalization was 10.2% versus 7.1% (hazard ratio 1.4, not significant). TAVR was associated with less bleeding and atrial fibrillation and with more nondisabling stroke, pacemaker implantation, and moderate or greater paravalvular regurgitation. In patients with tricuspid aortic valves, the rates were 8.7% and 8.3%, and in those with bicuspid valves 14.3% and 3.9% (Jørgensen 2024). At 3 years, freedom from death and disabling stroke (94.6% versus 95.1%) and the proportion with excellent health status (50.0% versus 45.0%) did not differ between groups (Phoksiri 2026).

DEDICATE randomized 1,414 patients at low or intermediate risk (mean age 74 years; median STS PROM 1.8%) in routine German practice. Death or stroke at 1 year occurred in 5.4% after TAVR and 10.0% after SAVR (hazard ratio 0.53; noninferior), with death 2.6% versus 6.2% (Blankenberg 2024).

For patients younger than 65 years, the 2020 ACC/AHA guideline recommends SAVR (Class 1), and the 2025 ESC/EACTS guideline recommends SAVR below 70 years at low surgical risk. TAVR in younger patients is reserved for those with increased surgical risk, limited life expectancy, or anatomy that makes surgery hazardous, and the plan for the second procedure is documented before the first.

TAVR in bicuspid aortic valves

Bicuspid valves were excluded from the pivotal randomized trials. Their anatomy challenges TAVR in predictable ways: an elliptical annulus, asymmetric and bulky leaflet calcium, a calcified raphe that resists frame expansion, a larger supra-annular dimension, and frequent dilation of the ascending aorta. The Sievers classification describes type 0 (two cusps without a raphe), type 1 (one raphe), and type 2 (two raphes). On CT, the anatomy is assessed at the annulus and at the supra-annular level, where the intercommissural distance and the calcified raphe can constrain the frame more than the annulus does.

In the STS/ACC TVT Registry, 2,691 propensity-matched pairs of patients with bicuspid and tricuspid stenosis treated with a balloon-expandable valve had similar mortality at 30 days (2.6% versus 2.5%) and 1 year (10.5% versus 12.0%) and similar paravalvular regurgitation and hemodynamics. Patients with bicuspid valves had a higher 30-day stroke rate (2.5% versus 1.6%) and more procedural complications requiring open surgery (0.9% versus 0.4%) (Makkar 2019). These are registry data in selected patients. In NOTION-2, the only randomized comparison with surgery that included bicuspid valves, the 1-year composite occurred in 14.3% after TAVR and 3.9% after SAVR in the 100 patients with bicuspid valves.

The 2020 ACC/AHA guideline lists bicuspid anatomy as a factor favoring SAVR. The 2025 ESC/EACTS guideline keeps surgery as the primary treatment of stenotic bicuspid valves, particularly in young patients or those with aortopathy, and lists TAVR as an option (Class 2b) at increased surgical risk with suitable anatomy. Bicuspid morphology and aortopathy are the subject of the bicuspid aortic valve and aortopathy page.

TAVR for native aortic regurgitation

Valves designed for stenosis anchor poorly in a noncalcified, dilated annulus, and their use in pure aortic regurgitation has been limited by embolization and paravalvular regurgitation. The JenaValve Trilogy valve anchors by clipping the native leaflets with locators and is designed for regurgitation. In ALIGN-AR, 180 symptomatic patients with moderate to severe or severe aortic regurgitation at high surgical risk (mean age 75.5 years) were treated at 20 US sites. Technical success was achieved in 95%. At 30 days, deaths occurred in 2%, disabling strokes in 1%, the composite safety end point in 27%, and new pacemaker implantation in 24%. Mortality at 1 year was 7.8%, and both performance goals were met (Vahl 2024). The valve was approved by the US Food and Drug Administration (FDA) in March 2026 for symptomatic severe native aortic regurgitation at high or greater surgical risk (FDA 2026). Surgery remains the standard treatment for patients who can undergo it. Grading and surgical indications in aortic regurgitation are covered on the aortic regurgitation page, and transcatheter treatment of aortic regurgitation during left ventricular assist device support under treatment of aortic insufficiency.

TAVR in special populations

Women and the small annulus. RHEIA randomized 443 women with severe aortic stenosis (mean age 73 years, mean STS PROM 2.1%) to transfemoral TAVR with a balloon-expandable valve or surgery. Death, stroke, or rehospitalization at 1 year occurred in 8.9% after TAVR and 15.6% after surgery, a difference driven mainly by fewer rehospitalizations (Tchetche 2025). Small annuli, which are common in women, favor a supra-annular self-expanding valve for hemodynamics (SMART). Sex differences in presentation and vascular complications are discussed under valve disease in women.

Dialysis. Patients receiving dialysis were excluded from the randomized trials. Among 72,631 TAVR patients in the STS/ACC TVT Registry, 3,053 (4.2%) were on dialysis; they had higher in-hospital mortality (5.1% versus 3.4%) and a 1-year mortality of 36.8% versus 18.7% (Szerlip 2019). Hemodialysis also carries the highest odds ratio among the comorbidities in the TVT in-hospital mortality model (3.25). The comparison with surgery is under TAVR and surgical valve replacement in dialysis.

Transthyretin (ATTR) amyloidosis. In a three-center study of 407 TAVR candidates screened with technetium-99m 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scintigraphy, uptake was present in 11.8%, with grade 2 or 3 uptake in 7.9%; in patients with both conditions, TAVR improved survival compared with medical management (Nitsche 2021). Coexisting amyloidosis is a common explanation for paradoxical low-flow, low-gradient stenosis and raises the risk of conduction disease after TAVR. The diagnostic approach is under aortic stenosis with ATTR amyloidosis.

Low-flow, low-gradient stenosis. Patients with low-flow, low-gradient stenosis and reduced ejection fraction have higher surgical risk and benefit from TAVR when the stenosis is truly severe. Confirmation with dobutamine echocardiography or the calcium score precedes the decision, as described under discordant grading and low-flow stenosis.

Other groups. TAVR in the very old and frail is discussed under aortic stenosis and TAVR in older adults, and in the irradiated chest under valve intervention after radiation. In pregnancy, balloon valvuloplasty and TAVR are the options when intervention cannot wait, because cardiopulmonary bypass carries high fetal risk. Transcatheter valves have not been studied in young women (pregnancy in aortic stenosis). In critically ill patients, balloon aortic valvuloplasty may be considered as a bridge to SAVR or TAVR (Class 2b), as described under balloon aortic valvuloplasty and palliative care. TAVR is also a reasonable way to avoid delaying semi-urgent noncardiac surgery in patients who meet criteria for valve replacement (noncardiac surgery in aortic stenosis).

Outcomes, quality of life, and resource use after TAVR

Registries. The STS/ACC TVT Registry links US procedures to Medicare claims and provides national outcome trends, risk models, and site-level observed-to-expected mortality. In 2019, about 8 of 10 patients were alive with acceptable patient-reported outcomes at 1 year (Carroll 2020). Risk-adjusted 30-day mortality rose modestly from 2019 to early 2022 despite stable unadjusted rates (Arnold 2024), as described under growth of TAVR.

Quality of life. The KCCQ is the standard patient-reported outcome after TAVR. In PARTNER 3, TAVR reduced the risk of a poor outcome (death or a low KCCQ score) at 30 days compared with surgery, reflecting faster recovery (Mack 2019), and patient-reported outcomes were similar between groups at 7 years (Leon 2026). In older, higher-risk patients, about one-third had a poor outcome at 6 months in PARTNER, which is why expected improvement in quality of life is part of the indication (Arnold 2014).

Length of stay and resource use. The median US hospital stay after TAVR was 2 days in 2019 (Carroll 2020), and next-day discharge is achievable in most transfemoral patients (Wood 2019). The 3M TAVR economic analysis found 30-day expenditure of $49,425 with the minimalist pathway and $60,729 with conventional transfemoral TAVR (Butala 2022). Lifetime cost-effectiveness of TAVR compared with SAVR in low-risk patients depends on device price, length of stay, and complication rates in the health system studied.

US coverage: the CMS national coverage determination and operator requirements

Medicare coverage of TAVR is governed by Centers for Medicare & Medicaid Services (CMS) national coverage determination 20.32. From the first version in 2012 through the 2019 revision, coverage required participation in coverage with evidence development through a national registry, with hospital and operator requirements. Version 3, effective in 2026, changed the requirements substantially (CMS 2026).

Element2019 national coverage determination2026 national coverage determination
Symptomatic severe aortic stenosisCovered under coverage with evidence developmentCovered without coverage with evidence development, for an FDA-approved device used for its approved indication
Asymptomatic severe aortic stenosisNot covered outside approved studiesCovered only under coverage with evidence development, in CMS-approved studies with a contemporaneous comparator
Patient evaluationIn-person evaluation by an interventional cardiologist and a cardiac surgeonHeart team evaluation that may be asynchronous with input from both specialties, plus an independent in-person evaluation by a heart team TAVR operator (a virtual encounter does not qualify), documented before the procedure day
Heart teamCardiac surgeon and interventional cardiologistAt least one cardiac surgeon and one interventional cardiologist experienced in aortic stenosis, with privileges at the hospital
OperatorsInterventional cardiologist and cardiac surgeon jointly participating in the procedureJoint operation not required; the operator is an interventional cardiologist or cardiac surgeon performing 20 or more transcatheter valve procedures a year with 15 or more TAVR, or 40 or more over 2 years with 30 or more TAVR
HospitalMinimum institutional surgical and transcatheter volumesNo hospital volume minimums; on-site structural heart and cardiac surgery programs, a postprocedure intensive care unit experienced with open valve surgery, and a continuous quality improvement process
RegistryParticipation in a national registry required for coverageNot a condition of coverage; registries may serve the quality improvement requirement

Medicare national coverage determination for TAVR: the 2019 and 2026 versions, from the CMS determination and the American College of Cardiology summary of the final decision.

The 2026 determination asks the heart team to assess suitability for SAVR, TAVR, close surveillance, and palliative care on clinical, anatomic, and procedural grounds, with attention to lifetime management and life expectancy. After the decision, the ACC, the Society of Thoracic Surgeons (STS), and the Society for Cardiovascular Angiography and Interventions (SCAI) stated jointly that participation in national registries and externally benchmarked quality programs remains essential to the quality of TAVR programs (American College of Cardiology 2026). The 2018 American Association for Thoracic Surgery (AATS)/ACC/SCAI/STS systems of care document sets the societies' operator and institutional recommendations for TAVR programs (Bavaria 2019).

Sources of error in TAVR selection, planning, and follow-up

References

  1. Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143:e72–e227. Corrections: Circulation. 2021;143:e229; 2023;148:e8; 2023;148:e185; 2024;150:e267. doi:10.1161/CIR.0000000000000923
  2. Praz F, Borger MA, Lanz J, et al. 2025 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2025;46:4635–4736. doi:10.1093/eurheartj/ehaf194
  3. Otto CM, Kumbhani DJ, Alexander KP, et al. 2017 ACC expert consensus decision pathway for transcatheter aortic valve replacement in the management of adults with aortic stenosis: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol. 2017;69:1313–1346. doi:10.1016/j.jacc.2016.12.006
  4. Lilly SM, Deshmukh AJ, Epstein AE, et al. 2020 ACC expert consensus decision pathway on management of conduction disturbances in patients undergoing transcatheter aortic valve replacement: a report of the American College of Cardiology Solution Set Oversight Committee. J Am Coll Cardiol. 2020;76:2391–2411. doi:10.1016/j.jacc.2020.08.050
  5. Généreux P, Piazza N, Alu MC, et al. Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research. J Am Coll Cardiol. 2021;77:2717–2746. doi:10.1016/j.jacc.2021.02.038
  6. Blanke P, Weir-McCall JR, Achenbach S, et al. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr. 2019;13:1–20. doi:10.1016/j.jcct.2018.11.008
  7. Bavaria JE, Tommaso CL, Brindis RG, et al. 2018 AATS/ACC/SCAI/STS expert consensus systems of care document: operator and institutional recommendations and requirements for transcatheter aortic valve replacement. J Am Coll Cardiol. 2019;73:340–374. doi:10.1016/j.jacc.2018.07.002
  8. Centers for Medicare & Medicaid Services. National coverage determination 20.32: transcatheter aortic valve replacement (TAVR), version 3, effective September 10, 2026. cms.gov
  9. Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106:3006–3008. doi:10.1161/01.cir.0000047200.36165.b8
  10. Carroll JD, Mack MJ, Vemulapalli S, et al. STS-ACC TVT registry of transcatheter aortic valve replacement. J Am Coll Cardiol. 2020;76:2492–2516. doi:10.1016/j.jacc.2020.09.595
  11. Arnold SV, Manandhar P, Vemulapalli S, et al. Trends in transcatheter aortic valve replacement outcomes: insights from the STS/ACC TVT Registry. JAMA Cardiol. 2024;9:1115–1123. doi:10.1001/jamacardio.2024.3453
  12. Edwards FH, Cohen DJ, O'Brien SM, et al. Development and validation of a risk prediction model for in-hospital mortality after transcatheter aortic valve replacement. JAMA Cardiol. 2016;1:46–52. doi:10.1001/jamacardio.2015.0326
  13. Arnold SV, Reynolds MR, Lei Y, et al. Predictors of poor outcomes after transcatheter aortic valve replacement: results from the PARTNER (Placement of Aortic Transcatheter Valve) trial. Circulation. 2014;129:2682–2690. doi:10.1161/CIRCULATIONAHA.113.007477
  14. Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients (PARTNER 3). N Engl J Med. 2019;380:1695–1705. doi:10.1056/NEJMoa1814052
  15. Popma JJ, Deeb GM, Yakubov SJ, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients (Evolut Low Risk). N Engl J Med. 2019;380:1706–1715. doi:10.1056/NEJMoa1816885
  16. Leon MB, Mack MJ, Pibarot P, et al. Transcatheter or surgical aortic-valve replacement in low-risk patients at 7 years. N Engl J Med. 2026;394:773–783. doi:10.1056/NEJMoa2509766
  17. Forrest JK, Yakubov SJ, Deeb GM, et al. 5-year outcomes after transcatheter or surgical aortic valve replacement in low-risk patients with aortic stenosis. J Am Coll Cardiol. 2025;85:1523–1532. doi:10.1016/j.jacc.2025.03.004
  18. Thyregod HGH, Jørgensen TH, Ihlemann N, et al. Transcatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial. Eur Heart J. 2024;45:1116–1124. doi:10.1093/eurheartj/ehae043
  19. Jørgensen TH, Thyregod HGH, Savontaus M, et al. Transcatheter aortic valve implantation in low-risk tricuspid or bicuspid aortic stenosis: the NOTION-2 trial. Eur Heart J. 2024;45:3804–3814. doi:10.1093/eurheartj/ehae331
  20. Phoksiri A, Maznyczka A, Savontaus M, et al. Comparison of health status after TAVI and SAVR in younger low-risk patients with aortic stenosis: a NOTION-2 analysis. Eur Heart J Valvular Struct Heart Dis. 2026;2:xwag068. doi:10.1093/ehjvshd/xwag068
  21. Blankenberg S, Seiffert M, Vonthein R, et al. Transcatheter or surgical treatment of aortic-valve stenosis (DEDICATE). N Engl J Med. 2024;390:1572–1583. doi:10.1056/NEJMoa2400685
  22. Tchetche D, Pibarot P, Bax JJ, et al. Transcatheter vs. surgical aortic valve replacement in women: the RHEIA trial. Eur Heart J. 2025;46:2079–2088. doi:10.1093/eurheartj/ehaf133
  23. Patterson T, Clayton T, Dodd M, et al. ACTIVATION (PercutAneous Coronary inTervention prIor to transcatheter aortic VAlve implantaTION): a randomized clinical trial. JACC Cardiovasc Interv. 2021;14:1965–1974. doi:10.1016/j.jcin.2021.06.041
  24. Lønborg J, Jabbari R, Sabbah M, et al. PCI in patients undergoing transcatheter aortic-valve implantation (NOTION-3). N Engl J Med. 2024;391:2189–2200. doi:10.1056/NEJMoa2401513
  25. Herrmann HC, Mehran R, Blackman DJ, et al. Self-expanding or balloon-expandable TAVR in patients with a small aortic annulus (SMART). N Engl J Med. 2024;390:1959–1971. doi:10.1056/NEJMoa2312573
  26. Baumbach A, van Royen N, Amat-Santos IJ, et al. LANDMARK comparison of early outcomes of newer-generation Myval transcatheter heart valve series with contemporary valves (Sapien and Evolut) in real-world individuals with severe symptomatic native aortic stenosis: a randomised non-inferiority trial. Lancet. 2024;403:2695–2708. doi:10.1016/S0140-6736(24)00821-3
  27. Makkar RR, Ramana RK, Gnall E, et al. ACURATE neo2 valve versus commercially available transcatheter heart valves in patients with severe aortic stenosis (ACURATE IDE): a multicentre, randomised, controlled, non-inferiority trial. Lancet. 2025;405:2061–2074. doi:10.1016/S0140-6736(25)00319-8
  28. Thiele H, Kurz T, Feistritzer HJ, et al. General versus local anesthesia with conscious sedation in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. Circulation. 2020;142:1437–1447. doi:10.1161/CIRCULATIONAHA.120.046451
  29. Greenbaum AB, Babaliaros VC, Chen MY, et al. Transcaval access and closure for transcatheter aortic valve replacement: a prospective investigation. J Am Coll Cardiol. 2017;69:511–521. doi:10.1016/j.jacc.2016.10.024
  30. Wood DA, Lauck SB, Cairns JA, et al. The Vancouver 3M (multidisciplinary, multimodality, but minimalist) clinical pathway facilitates safe next-day discharge home at low-, medium-, and high-volume transfemoral transcatheter aortic valve replacement centers: the 3M TAVR study. JACC Cardiovasc Interv. 2019;12:459–469. doi:10.1016/j.jcin.2018.12.020
  31. Butala NM, Wood DA, Li H, et al. Economics of minimalist transcatheter aortic valve replacement: results from the 3M-TAVR economic study. Circ Cardiovasc Interv. 2022;15:e012168. doi:10.1161/CIRCINTERVENTIONS.122.012168
  32. Tang GHL, Zaid S, Fuchs A, et al. Alignment of transcatheter aortic-valve neo-commissures (ALIGN TAVR): impact on final valve orientation and coronary artery overlap. JACC Cardiovasc Interv. 2020;13:1030–1042. doi:10.1016/j.jcin.2020.02.005
  33. Barbanti M, Costa G, Picci A, et al. Coronary cannulation after transcatheter aortic valve replacement: the RE-ACCESS study. JACC Cardiovasc Interv. 2020;13:2542–2555. doi:10.1016/j.jcin.2020.07.006
  34. Ribeiro HB, Webb JG, Makkar RR, et al. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry. J Am Coll Cardiol. 2013;62:1552–1562. doi:10.1016/j.jacc.2013.07.040
  35. Khan JM, Greenbaum AB, Babaliaros VC, et al. The BASILICA trial: prospective multicenter investigation of intentional leaflet laceration to prevent TAVR coronary obstruction. JACC Cardiovasc Interv. 2019;12:1240–1252. doi:10.1016/j.jcin.2019.03.035
  36. Mercanti F, Rosseel L, Neylon A, et al. Chimney stenting for coronary occlusion during TAVR: insights from the chimney registry. JACC Cardiovasc Interv. 2020;13:751–761. doi:10.1016/j.jcin.2020.01.227
  37. Ribeiro HB, Rodés-Cabau J, Blanke P, et al. Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry. Eur Heart J. 2018;39:687–695. doi:10.1093/eurheartj/ehx455
  38. Shatila W, Krajcer Z. A cardiologist's nightmare: coronary obstruction during transcatheter aortic valve implantation: how to identify patients at highest risk for this complication. Catheter Cardiovasc Interv. 2017;90:1198–1199. doi:10.1002/ccd.27425
  39. Khan JM, Kamioka N, Lisko JC, et al. Coronary obstruction from TAVR in native aortic stenosis: development and validation of multivariate prediction model. JACC Cardiovasc Interv. 2023;16:415–425. doi:10.1016/j.jcin.2022.11.018
  40. Makkar RR, Gupta A, Inglessis I, et al. Real-world outcomes of dedicated leaflet modification for bioprosthetic valve-in-valve TAVR: a 150-patient commercial experience. JACC Cardiovasc Interv. 2026;19:2459–2470. doi:10.1016/j.jcin.2026.06.002
  41. Sato S, Ninomiya R, Tosaka K, et al. Risk of coronary occlusion due to sinus sequestration by redo transcatheter aortic valve implantation in Japanese patients with SAPIEN 3. Circ Rep. 2023;5:217–224. doi:10.1253/circrep.CR-23-0039
  42. Koshy AN, Tang GHL, Khera S, et al. Redo-TAVR feasibility after SAPIEN 3 stratified by implant depth and commissural alignment: a CT simulation study. Circ Cardiovasc Interv. 2024;17:e013766. doi:10.1161/CIRCINTERVENTIONS.123.013766
  43. Kapadia SR, Makkar R, Leon M, et al. Cerebral embolic protection during transcatheter aortic-valve replacement (PROTECTED TAVR). N Engl J Med. 2022;387:1253–1263. doi:10.1056/NEJMoa2204961
  44. Kharbanda RK, Kennedy J, Jamal Z, et al. Routine cerebral embolic protection during transcatheter aortic-valve implantation (BHF PROTECT-TAVI). N Engl J Med. 2025;392:2403–2412. doi:10.1056/NEJMoa2415120
  45. Siontis GC, Jüni P, Pilgrim T, et al. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol. 2014;64:129–140. doi:10.1016/j.jacc.2014.04.033
  46. Jilaihawi H, Zhao Z, Du R, et al. Minimizing permanent pacemaker following repositionable self-expanding transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2019;12:1796–1807. doi:10.1016/j.jcin.2019.05.056
  47. Rodés-Cabau J, Urena M, Nombela-Franco L, et al. Arrhythmic burden as determined by ambulatory continuous cardiac monitoring in patients with new-onset persistent left bundle branch block following transcatheter aortic valve replacement: the MARE study. JACC Cardiovasc Interv. 2018;11:1495–1505. doi:10.1016/j.jcin.2018.04.016
  48. Hazique M, Jafar Z, Lohana S, et al. The cusp overlap technique reduces pacemaker implantation in TAVR: a systematic review and meta-analysis. Am J Cardiol. 2025;254:75–84. doi:10.1016/j.amjcard.2025.06.024
  49. Kim WK, Schäfer U, Tchetche D, et al. Incidence and outcome of peri-procedural transcatheter heart valve embolization and migration: the TRAVEL registry (TranscatheteR HeArt Valve EmboLization and Migration). Eur Heart J. 2019;40:3156–3165. doi:10.1093/eurheartj/ehz429
  50. Tilley E, Psaltis PJ, Loetscher T, et al. Meta-analysis of prevalence and risk factors for delirium after transcatheter aortic valve implantation. Am J Cardiol. 2018;122:1917–1923. doi:10.1016/j.amjcard.2018.08.037
  51. Brouwer J, Nijenhuis VJ, Delewi R, et al. Aspirin with or without clopidogrel after transcatheter aortic-valve implantation (POPular TAVI). N Engl J Med. 2020;383:1447–1457. doi:10.1056/NEJMoa2017815
  52. Dangas GD, Tijssen JGP, Wöhrle J, et al. A controlled trial of rivaroxaban after transcatheter aortic-valve replacement (GALILEO). N Engl J Med. 2020;382:120–129. doi:10.1056/NEJMoa1911425
  53. Raposeiras-Roubin S, Amat-Santos IJ, Rossello X, et al. Dapagliflozin in patients undergoing transcatheter aortic-valve implantation (DapaTAVI). N Engl J Med. 2025;392:1396–1405. doi:10.1056/NEJMoa2500366
  54. Regueiro A, Linke A, Latib A, et al. Association between transcatheter aortic valve replacement and subsequent infective endocarditis and in-hospital death. JAMA. 2016;316:1083–1092. doi:10.1001/jama.2016.12347
  55. Makkar RR, Kapadia S, Chakravarty T, et al. Outcomes of repeat transcatheter aortic valve replacement with balloon-expandable valves: a registry study. Lancet. 2023;402:1529–1540. doi:10.1016/S0140-6736(23)01636-7
  56. Bapat VN, Zaid S, Fukuhara S, et al. Surgical explantation after TAVR failure: mid-term outcomes from the EXPLANT-TAVR international registry. JACC Cardiovasc Interv. 2021;14:1978–1991. doi:10.1016/j.jcin.2021.07.015
  57. Durand E, Eltchaninoff H, Tchetche D, et al. Predictors of outcomes of reintervention after transcatheter aortic valve replacement: FRANCE 2 and FRANCE TAVI registries. J Am Coll Cardiol. 2025;85:896–907. doi:10.1016/j.jacc.2024.11.048
  58. Makkar RR, Yoon SH, Leon MB, et al. Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke. JAMA. 2019;321:2193–2202. doi:10.1001/jama.2019.7108
  59. Vahl TP, Thourani VH, Makkar RR, et al. Transcatheter aortic valve implantation in patients with high-risk symptomatic native aortic regurgitation (ALIGN-AR): a prospective, multicentre, single-arm study. Lancet. 2024;403:1451–1459. doi:10.1016/S0140-6736(23)02806-4
  60. Szerlip M, Zajarias A, Vemalapalli S, et al. Transcatheter aortic valve replacement in patients with end-stage renal disease. J Am Coll Cardiol. 2019;73:2806–2815. doi:10.1016/j.jacc.2019.03.496
  61. Nitsche C, Scully PR, Patel KP, et al. Prevalence and outcomes of concomitant aortic stenosis and cardiac amyloidosis. J Am Coll Cardiol. 2021;77:128–139. doi:10.1016/j.jacc.2020.11.006
  62. Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aortic-valve replacement in low-risk patients at five years. N Engl J Med. 2023;389:1949–1960. doi:10.1056/NEJMoa2307447
  63. Makkar RR, Chakravarty T, Gupta A, et al. Valve underexpansion and clinical outcomes with ACURATE neo2: findings from the ACURATE IDE trial. J Am Coll Cardiol. 2025;86:225–238. doi:10.1016/j.jacc.2025.05.011
  64. American College of Cardiology. CMS finalizes updated TAVR national coverage determination. September 2026. acc.org
  65. Pagnesi M, Martino EA, Chiarito M, et al. Silent cerebral injury after transcatheter aortic valve implantation and the preventive role of embolic protection devices: a systematic review and meta-analysis. Int J Cardiol. 2016;221:97–106. doi:10.1016/j.ijcard.2016.06.143
  66. US Food and Drug Administration. Premarket approval P250024: Trilogy Transcatheter Heart Valve System. Decision date March 17, 2026. accessdata.fda.gov